Post Job Free

Resume

Sign in

Technician Electrical

Location:
Riyadh, Riyadh Province, Saudi Arabia
Salary:
3000
Posted:
October 28, 2016

Contact this candidate

Resume:

Objectives

Seeking a challenging, responsible & career-oriented position where I can apply my professional and inter-personal skills to contribute significantly to the growth of the organization.

EXPERIENCE: GULF- 1.5 Year & Pak-2.5 Year

COMPANY: AGC

PROJECT

@Aramco project (Abu-Jifan &Khurais)

POSITION

Electrical Foreman

DURATION

May-2016 till now

COMPANY: SAMSUNG ENGINEERING (RAS AL KHAIR KSA)

PROJECT

Maadan Rolling Mill

POSITION

Electrical Supervisor

DURATION

Feb-2016 to May-2016

COMPANY: PAK ARAB OIL REFINERY (PARCO)

PROJECT

Diesel Desulfurization Project

POSITION

Electrical Supervisor

DURATION

Oct-2014to Dec-2015

COMPANY: LAL PIR THERMAL POWER STATION (MUZAFAR GARH)

PROJECT

Major Shutdown

POSITION

Electrical Trainee Supervisor

DURATION

Sep-2013 to Sep-2014

JOB RESPONSIBILITIES:

Preparing yearly schedule of testing for substations Circuit Breakers, protective Relays, Overhead Cranes and other control panels (Protection).

Distribution, Supervision and Assigning of Work to Technicians.

To prepare progress reports.

Material receiving inspection.

Installation inspection.

Testing inspection.

Preparing monthly cost accounting report.

Be ready to face my electrical / control departmental emergencies.

O&M, TROUBLE SHOOTING:

Power Plant, Sub Stations & Power Plant Auxiliaries.

Fire Alarm (SIEMENS)

LV, MV Electrical Panels, CTs, VTs & Power Transformers.

Protective Relays Circuit Breakers, Control Devices and Testing Equipment’s.

Electrical Power Distributions & Control Circuits.

Lift, AC, DC Motors, Invertors & Dc Drives.

TURN OVER PACKAGES:

oPrepares turn over packages of all the systems

oAs built as Drawings

oPunch Lists

Education

D.A.E (Electrical) from PBTE Lahore-Pak in Year-2013

Matriculation (Science) from BISE Gujranwala in Year-2010.

Professional Qualification

HSE in construction Safety Management (Oil & Gas Projects)

First Aid Training Course

Proficient on utilization of MS Office, MS Windows.

User of MS Project software.

Adobe photo shop 2007

Strength& Communication

Maintain positive attitude in the face of changes in work assignment.

Ability to inspire creativity and co-operation among team members adaptable to circumstances.

Ability to lead Instrument, Electrical, communication team for Inspection, construction, commissioning & startup team.

Self-assured, self-confidence and self-motivated.

Open minded, organized, productive and practical.

Quality, Time and cost management.

Excellent Monitoring skills

Personal Information:

Iqama No.240-***-****

Transferable

Date of Birth

07-May-1994

Marital Status

Single

Passport No

CG5527641

Permanent Address

INSTALATION:

Experienced for the installation of equipments as per approved construction drawings, such as Power transformers, Switchgear, Motor Control centers, Control panels, Station Batteries, UPS, HVAC system, Fire Alarm system, PAGA system, Grounding Grids, ground rods/ Cad welding, Cathodic protection system, Anodes installation, Plant lighting system, cable trays and conduits/race ways installation.

HANDS ON TESTING/COMMISSIONING EXPERIENCE:

Power and control cable Insulation Resistance testing (IR Test)

Hi-Pot test

DLRO

Megger and continuity test

Ground resistance test

Illumination testing for lighting systems

Testing of Cathodic protection system

Testing of Electrical heat tracing system

Testing of HVAC systems

Testing of Fiber Optic Networks

Testing of Fire Alarm systems by smoke and heat detectors

FINAL LOOP TESTING/SIMULATION

Control circuit testing of switchgear/MCCs.

Functional testing of transformer protective devices

Simulation of MCCs from Interposing Relay panels/Marshalling cabinets/DCS.

Functional testing of Analyzer shelters

Solo run test of Plant motors

PROJECT PHASE EXPERIENCE:

Panel installation (11 KV Switchgear, PMCs, L.V Switchgear)

Power, control, communication cables laying

Grounding Work

Lighting Work

Cable laying, dressing and routing

Tray and Conduit installation

220KV Grid Station equipments installation including CTs, PTs, SF6 Circuit Breakers,

Cable Glanding( to check proper Gland installation)

Cable Termination (HT Termination, LT Termination, Splicing of cables)

Cathodic Protection Work

Commissioning of protection system including interlocking and relay testing (Over current, Earth fault.

Calibration of some instruments (Local Indicators )

Installation of MV/LV Switchgear, Capacitor Bank. Preparation and Supervision of loading and unloading of GIS from client where house to GIS Hall for Installation as per vendor’s instructions. Arrangement of temporary Electricity .

Installation of Battery Bank UPS, LVAC, HVAC, Panels and 11KV Switchgear.

Installation of Instrument JB’s Perforated Tray and Plant Lighting. Tray and Conduit routing for Lighting, Termination of Instrument JB’s and Lighting.

Installation of Cable Ladder Tray, Plant Lighting, UPS, PLC Panel and Battery Bank.

All activities of Switch Gear Building, Installation of MV / LV Switch Gear Cable Laying Glanding Termination.

RESPONSIBILITIES AS A QUALITY CONTROL ENGINEER E/I:

Responsible to raise the RFI (Request for Inspection) and arrange the site inspection as per Hold/Witness with client representatives.

Issuance of NCR (Non-conformance report) for discrepancies as per material system specifications.

Inspection of power/control/signal cables for cable laying.

Cable termination and testing records for Hi-potential testing, Megger testing and continuity testing.

Installation inspection of H.V/L.V Switchgears, MCCs, Local Control Stations, Transformers, and utility outlets.

Installation inspection of lighting fixtures and record the Lighting Illumination tests as per SAES requirements.

Witness the installation of Grounding systems, Thermit Welding and report the Ground Resistance testing records.

Inspection for the installation of Cable trays and conduit in classified and Non-classified areas as per SAES, NEMA and NEC accordingly.

Inspection and testing of Cathodic Protection System

Pre-commissioning of Fire Alarm systems, HVAC system, Public Addressing systems, Close circuit television system, and Plant telecommunication systems.

Testing of smoke detectors, temperature detectors and laser detectors

Preparing calibration record of all types of skid-mounting instruments (Pressure, Level, Flow, Temperature and Vibration types).

Issuance of punch listing as per project scope of work.