Address: Faisal colony near Kausar Masjid
Piran Ghaib Road Multan Pakistan
Cell #: +92(0)302-***-****, +92(0)300-***-****, / +966*********
Home#:+92(0)616778640
E-mail: ***********@*****.***
DOB: 25March1989
NIC: 36302-5285360-7
MUHAMMAD SOHAIL
Education
2013 Newport’s Institute of Higher Education, Karachi.
B -TECH (Electrical)
1ST DIVISION
2009 GOVT COLLEGE OF TECHNOLOGY MULTAN
DAE (Electrical)
1ST DIVISION
2005 BOARD OF SECONDARY EDUCATION MULTAN
SSC (Science)
1ST DIVISION
Summary of experience:
Six Years of Professional Experience in Power Plants, Oil & Gas, FMCG projects as a Electrical Supervisor worked in SAUDI ARABIA & PAKISTAN in areas of maintenance, installation, and testing of 17.8KV Switchgear, Transformer, PMCC, APFC Panels, ACB, VCB, Bus Duct, VFD, Soft Stators, MCB,MCCB, SWS, LCS, LV Motors, cable laying, Termination of MV LV cables jointing and trouble shoot of electrical equipments . Well Experience in Electrical related drawings Familiar with codes and standards
Objective
Looking forward for long-term associations with people oriented organization where individual Talents, skills, honesty and hard work are acknowledged and conductive work culture is provided.
Technical skills:
Inspection, Installation & Commissioning with Siemens Vendor 24KvSwitchgear
Inspection, Installation & Commissioning with ABB Vendor
(10kvaTransformers with Bus Duct, 3200A PMCC, APFC panels, ACB, VCB, LV Motors, VFD,
Soft Stators, SWS, LCS)
High pot testing of Switchgear (Up to 50 KV)
Insulation Testing of MV, LV Cable & Termination ( Megger & VLF)
Cable Lying, Termination and Jointing MV,LV
Familiar with Fluke Digital Ground Resistance tester,Tong tester, Earth Resistance tester cable fault locator (Seba-KMT), Cable Tracer
Punch List Preparation
Preventive and Corrective maintenance and Trouble Shoots of (lighting, Magnetic Contactors, relays HRC fuses Breakers MCB,MCCB,ACB protection of Motors, Actuators, VFD and Soft Stators)
Work Experience:
Responsibilities:
Installation of 24KV Switch gear their alignments adjustment, and Earth connected, Bus Bar, CT, PT installation, internal wiring testing and commissioning with SIEMENS VENDOR.
Installation of 10Mva Transformer, Bus Duct, PMCC,APFC,ACB,VCB panels, Soft Stator internal wiring alignment Testing and pre commissioning with ABB VENDOR
Installation of Cable Tray, Cable laying, LV Motors, SWS, LCS, Actuators, VFD, Lighting Arrestor, Earth Dispatcher, as per Drawings
Solid knowledge of jointing and Termination of LV MV cables.
Installation, testing and commissioning of 360 ton chilled plant.
Installation, testing and maintenance of AHU, FCU, Exhaust fan & refrigeration system.
Preventive and Corrective maintenance, trouble shooting lighting, Magnetic Contactors, relays and HRC fuses Breakers MCB,MCCB,ACB protection of Motors, Actuators, VFD and Soft Stators.
Proper earthling of equipments on international standard and proper testing and check continuity testing procedures.
Proven ability to read schematics and work plan.
Strong background in reading& interpreting instruction of Electrical, instrument & HVAC system.
Replace faulty parts of Electrical & HVAC system.
Operate 100 HP chilled water pumps.
Operate 30gxnr350 carrier chillers.
Solid knowledge of using power and hand tools.
Using Electrical Instruments of AVO meter, Megger 552, Relay tester 750, fluke digital grounding, resistance tester, tong tester, earth resistance tester, cable fault locator (seba-KMT) cable tracer etc.
Performing the job according to drawings and project client specifications
Involved in Pre-Commissioning activities.
Sending feed backs to the line managers for maintaining the project schedule on time. Having a working knowledge in g Oil & Gas, Power and FMCG field with all kind of Maintenance and erection inspection techniques for various applicable standards.
Fabrication of tray structural supports, monitoring construction and maintenance activities and Schedule, weekly & monthly progress report, co-ordination with other discipline and supervising Field Erection.
Performing construction and Maintenance activities.
Clearing the punch list items, construction activities and site modifications advices from client & Quality Control department as well.
Co-ordination with the Clint.
Maintain daily progress Reports, schedule records and report the status performed to the Construction Manager.
Participating and preparing of Task Risk Assessment for the given job to categorize and measure the precaution for the task to carryout job safely and without LTI.
Safety Procedures Implementation
work permits and follow the safety procedures
Use of Personal Protective Equipments (PPE)
Project of Dora Dora Plant Saudi Arabia 23/07/2015 to till now
Client: MEFSCO
Contractor: AL-SINSINA
Designation: ELECTRICAL SUPERVISOR
Project of NADEC Power plant 90MW Saudi Arabia 05/09/2014 to 24/04/2015
Client: NADEC
Designation: ELECTRICAL FOREMAN
PakArab Refinery pvt Ltd Pakistan 21/07/2013 to 22/08/2014
Client: PARCO
Contractor: DESCON ENGINEERING (Pvt) Ltd
Designation: ELECTRICAL TECHNICIAN
Project of Qadirpur Gas Field Distt. Ghotki Pakistan12/10/2011 to 05/04/2013
Client DESCON ENGINEERING (Pvt) Ltd
Designation: ELECTRICAL TECHNICIAN
Pak Arab Fertilizer Multan Pakistan 25/07/2009 to 06/09/2011
Client: Pak Arab
Designation: ELECTRICAL TECHNICIAN
Computer Skills
MS Office. Excel
Installation of Window
Auto CAD