Post Job Free
Sign in

Electrical Foreman / Technician

Location:
India
Posted:
June 14, 2016

Contact this candidate

Resume:

MOHAMED ZUBAIR

Contact: +**786**-*****

+**904**-*****

Email: *********@*****.***

INTRODUCTION

Technically competent Electrical Diploma Engineer (D.E.E.E) Offering an Impressive Experience of 15 Years in Delivering Optimal Results in High-growth Environments with base functional knowledge of:

Planning/ Scheduling ò Protection Systems ò Testing & Commissioning ò Troubleshooting & Predictive Breakdown ò Optimal Resource Utilization ò Inventory Management ò Quality Initiatives ò Cross Functional Coordination

EMPLOYMENT HISTORY IN BRIEF

Exclusive 15 Years of Total Experience out of which 7 Years in Electrical Maintenance of Power Generation Plants (Gas & Steam Turbine), 5 Years in other Industries and 3 Years in Erection, Testing & Commissioning of Protection Relays, Transformers, HV & LV Switch Gears, Motor Control Centre Panels, LV Cables and Transformer oil Filtration.

4 Years as Senior Electrical Technician with Dubai Electricity and Water Authority (DEWA) Dubai.

2 Years as Electrical Supervisor with Nuclear Power Corporation of India Limited, Kaiga–3&4.

3 years as Electrical Engineer with Khader Spinners (P) Ltd., Dindigul.

1 Year as Electrical Engineer with Devi Marine Food Exports Limited, Chennai.

3 Years as Testing Engineer with Emaar Electricals, Chennai.

Recently as Technician - Transformer with Marafiq Power & Water Utility Company - Yanbu, KSA.

CORE COMPETENCIES

Carry out Testing / Inspection, Preventive, Corrective and Break-down Maintenances on electrical systems, such as:

-Electrical Protection Systems related to protection circuits of Generators, Transformers, Unit & Station (MV/LV) Switch Boards, Connected load through LV Switch Gears, MCCs, Aux. Equipment Control Panels, Battery Banks and DC Distribution Systems

-MV Motors / LV Motors, feeders (SWGR) and control circuits

-Turbo Generators, Transformers, HV SWGR, MV SWGR, LV SWGR, MV & LV Cables, Electrical submersible pumps (ESP), Motor operated valves (MOV) etc…

Implement and observe the Company’s LOTO, PTW, HSE policies and procedures.

Receive work orders, Repair work requests, identifying and ordering required materials, spares and equipment through Computer Assisted Software.

Conduct Inspection and Testing of newly received equipments, spares and or instruments to ensure the healthiness and correctness of the product.

Assist and participate in Repair activities carried out by specialists, as required.

Participate in shutdown and major overhaul activities by carrying out shutdown preparation, data collection and condition monitoring duties as assigned by Senior Engineers.

Strong commercial acumen, capable of coordinating and negotiating with the vendors for cost effective purchase of spare parts while adhering to quality of the incoming materials; experience in preparing Check list, Inspection & Testing Reports and other documents.

PROFESSIONAL EXPERIENCE IN DETAIL

MARAFIQ – POWER & WATER UTILITY COMPANY FOR JUBAIL & YANBU

Technician – Transformer Maintenance January 2015 – September 2015

Involve in all Construction, Commissioning and Maintenance Phases activity related to Transformers which includes:

-360MVA, 18 kV/380 kV Main Step-Up Transformers – 2 No’s.

-360MVA, 18 kV/115 kV Main Step-Up Transformer – 1 No.

-75MVA, 18 kV/13.8 kV Unit Auxiliary Transformers – 3 No’s.

-13.8 kV/4.16 kV Medium Voltage Transformers and associated Switch Gears

-13.8 kV/480 V Transformers and associated Switch Gears

-4.16 kV/480 V Distribution Transformers and associated Switch Gears

-Cast resin Transformers and Dry type Transformers installed at various locations in the plant.

Look after preventive and breakdown maintenance of all Electrical and Instrumentation; maintain all records of power consumption.

Inspects Transformer Windings during breakdown and periodically for pre-defining Transformer faults.

Co-ordinate with Vendor during Transformer repair, Winding replacement partially or fully as required.

Administer the planning of general maintenance and shutdown schedules and oversee the entire overhauling of equipment / installations to prolong operational life of equipment.

Adeptly perform root-cause analysis of defects while developing & improving the processing by taking corrective actions to prevent any reoccurrences and defective issues.

Contribute significantly in generating energy savings by ensuring observance of correct operational parameters.

Modify efforts to ensure minimum breakdown & Prepare periodic maintenance plan for all machines and instruments.

KHADER SPINNERS (P) LIMITED, DINDIGUL

Electrical Maintenance Engineer July 2011 – October 2014

In-charge for all Electrical Operation & Maintenance Activities which includes:

-22 KV / 433 Volt Transformers: 750 KVA – 2 Nos. & 500 KVA – 1 No.

-Diesel Generator Sets: 600 KVA – 1No. & 380 KVA – 2 No’s.

-HV/LV Switchgears, Panels, Cables, DBs, Lighting System.

Look after preventive and breakdown maintenance of all Electrical and Instrumentation; maintain all records of power consumption.

Perform Transformer repair, Winding Inspection and Transformer oil filtration and oil changing activity.

Monitor condition of equipment and initiate advance action to prevent any major breakdown.

Adeptly perform root-cause analysis of defects while developing & improving the processing by taking corrective actions to prevent any reoccurrences and defective issues.

Contribute significantly in generating energy savings by ensuring observance of correct operational parameters.

Modify efforts to ensure minimum breakdown, making maintenance plan for smooth running of plant.

Prepared periodic maintenance plan for all machines and instruments.

DUBAI ELECTRICITY AND WATER AUTHORITY [DEWA] JEBEL ALI POWER STATION (JAPS)

Senior Electrical Technician July 2007–May 2011

Performed Preventive, Predictive, Corrective, and Overhaul Maintenance of Electrical Equipments:

-Air-cooled Gas Turbine Generators of 90 MW each (Type T240 – 370 of GEC ALSTHOM)

-Steam Turbine Generators of 105 MW and 60 MW of M/s. ABB

-Emergency Diesel Generator sets of 1850 KVA each of type ALPC 630 A6 from SCAM Diesel

-160 MVA & 140 MVA Power Transformers, 2 MVA Unit Aux. Transformers, Excitation Transformers & Distribution Transformers of up to 2000 KVA

-Inspection of HV & LV side bushings, Neutral bushings, Breather, Bucholz Relay, Winding-Temperature RTD, Oil Temperature RTD, and Magnetic Oil Level Gauge

-Overhaul / Periodic testing of Winding Resistance and IR value of HV Motors of up to - 1000 KW and LV Motors of up to 120 KW

-6.6 KV, 2000 A - Switchgear Panels, SF6 Breakers – 1200 A capacity, Vacuum Rupturing Contactors-(ABB), LV – 4000 A Switchgear Panels, Air Circuit Breakers of up to 1200 A (GEC ALSTHOM & ABB)

-Batteries of up to 900 AH, Battery Chargers of up to 800 A, and UPS & Inverters of 50 KVA

-Motor Operated Valve and it’s Module

-Trial operation of Emergency Diesel Generator Sets to ensure their readiness and healthiness

-Testing of Protection Relays related to protection circuits of Generators, Transformers, Unit & Station (MV/LV) Switch Boards, MCCs, Aux. Equipment Control Panels, Battery Banks and DC Distribution Systems

Handling latest Secondary Injection Kits and Power System Simulators like DOBLE-F6150.

Conducted root cause analysis of failures and evolve quick breakdown solutions to put the machines/ equipments back in operation.

Provided effective leadership to the team and work towards improving quality and productivity.

Received work-orders and repair work-requests through computer generated software “Maximo”

Maintain Inventory and availability of minimum required spares in stores to ensure Zero loss time in production.

NUCLEAR POWER CORP. OF INDIA LIMITED (NPCIL) KAIGA 3 & 4 (Outsourced by Kushal Tech-Services Pvt. Limited, Mumbai)

Electrical Maintenance Supervisor July 2005–June 2007

Represented NPCIL - Electrical Maintenance Unit (EMU) in commissioning of the newly installed Power Plant equipments. Anchored and coordinated on-site activities to ensure smooth work progress and conceptualized and implemented measures for enhancing operational efficient and optimizing resource utilization.

Associated with the main contractor M/s. Reliance Energy Limited on system takeover.

Performed routine maintenance to the installed equipments such as:

-260 MVA – 400KV/16.5 KV Generator Transformer

-35 MVA – 16.5 KV/6.9 KV Unit Auxiliary Transformer

-M/s. AREVA T&D (France) make 16.5 KV – 10 KA Generator Circuit Breaker

-600 KVA Power UPS

-M/s. Exide make Power Battery Banks for Station Class-II Power Supply

-10 KA – IPBD (Isolated Phase Bus Duct) connecting from 260 MVA Turbo Generator to 400 KV- Generator Transformer

-MV & LV Switch Gears, Panels and Motor Control Centres

-Lighting Systems at Turbine Building, Control Building, and Service Building of the Power Plant

DEVI MARINE FOOD EXPORTS LIMITED, CHENNAI

Electrical Engineer July 2004–June 2005

In-charge of Electrical department which includes Operation & Maintenance of:

-11 KV / 433 Volt – 1 MVA Transformer – 1 No; 11 KV / 433 Volt – 500 KVA Transformers – 2 Nos.

-380 KVA Diesel Generator Sets – 3Nos; 312.5 KVA Diesel Generator Sets – 2 Nos.

-HV & LV Switchgears, Panels, Cables, DBs & Lighting System

EMAAR ELECTRICALS, CHENNAI

Testing Engineer July 2001–June 2004

Initially acquired experience of the field by being as a trainee and shortly started carrying out the works individually which includes:

Testing of different Conventional and Digital Protection Relays like Over Current, Earth Fault, Under Voltage, Differential, Under frequency, Motor protection, Over fluxing Relays, etc., of M/s. ABB & M/s. GEC ALSTHOM

Testing of Power and Distribution Transformers, HV & LV Switch Gears (SF6, VCB, ACB, OCB and MCCB) / with thermal relays and numeric relays, Potential Transformers (VT), Current Transformers (CT) etc...

High Voltage testing of Cables / Bus bars / Panels

Transformer Oil Filtration, leak arrest, repairs, Control Circuit Wiring from Transformer Marshalling panel to OLTC panel and Commissioning the same

ACADEMIA

Diploma in Electrical & Electronics Engineering (D.E.E.E.) First Class with 74.3%

Course Duration: June - 1998 to April - 2001 (3 Years)

University/College: P.S.B. Polytechnic College, Chennai.

GOVERNMENT LICENSE

Having a Supervisor Competency ‘License-C’

Issued by Tamil Nadu (Govt.) Electrical Licensing Board [TNELB]

C-License No: C-41494

PERSONAL DETAILS ADDRESS FOR COMMUNICATION

Father Name: LIYAKATH ALI No. 2 / 7, 5th Street, Thiru Nagar,

Date of Birth: 07-09-1982 Vadapalani, Chennai

Marital Status: Married Tamilnadu, India.

Languages Known: Tamil, English & Hindi PIN Code: 600 026



Contact this candidate