Post Job Free
Sign in

Maintenance Project

Location:
United States
Salary:
According to the company standard.
Posted:
June 14, 2016

Contact this candidate

Resume:

PETER AGEH IGELLE

No **a Old Court Road Abakpa Ogoja Cross River State.

Telephone Number: 080********, 081********.

E-mail Address:*********@*****.**

Career Objective: To serve with diligence and commitment for attainment of the company’s goal of providing quality services to the public.

PERSONAL INFORMATION

Date of birth: 25th February 1982.

Sex: Male.

Marital status: Married.

Home Town: Ipollo-Ntrigom.

Religion: Christian.

Local Govt Area: Yala.

State Of Origin: Cross River.

Nationality: Nigerian.

EDUCATIONAL QUALIFICATION & CERTIFICATE OBTAINED YEAR

Cross River University Of Technology Calabar.

B.Eng. Electrical / Electronic Engineering. 2003 to 2008.

Government Technical College Abakpa Ogoja, C.R.S.

O, Level Certificate. 1993 to 1999.

Government Primary School, Abakpa Ogoja, C.R.S.

First School Living Certificate. 1987 to 1993.

TRAINING AQUIRED

Basic operational training on 330kv, 132kv and 33kv substation plant by (ALSTOM)

Confine space training by (ALCON NIG LTD)

PROFESIONAL EXPERIENCE

Company: Alcon Nigeria Limited

Client: Shell Petroleum Development Company (SPDC)

PROJECT: Soku NAG Compression & Installation Facility Project

POSITION: Instrument Supervisor

DATE: May 2014 Till Date.

Job Description.

Calibration, function test/ simulation of various fields’ instruments, installation of local control Panels & fabrication of cable trays.

General maintenance & overhauling of electrical motors, excitation systems, MV & LV bus bars.

Stroke checking of control valves, servicing and overhauling of control/PSV valves calibration.

Ensuring that all electrical & Instrument devices and equipment are installed according to the approved construction drawings.

General maintenance & trouble shooting of transmitting equipment.

Ensuring that all construction and engineering activities are carried out according to Shell specifications and standards.

Carry out test e.g. Continuity checks, insulation resistant test and meggering before and after installation of cables.

Routine checks on all site installations, punch for incomplete/unfinished installation and notification of clearing of Punch items.

Inspection of installed earthling/grounding & lightning protections, fire alarms and detection systems, communication system, panel and junction box installations, low and medium voltage cable test with approved drawings.

Glanding and termination of electrical and instrument devices.

Yokogawa DCS model cs 300 configuration, commissioning documentation, installation, integration and functionality testing of DCS SCADA and PLC/HMI.

In house documentation of test reports, permit to work preparation.

Good knowledge to interpret P & IDs drawing for instrumentation.

Logic wiring on safety instrument system (SIS) panel by YOKOGAWA.

Good knowledge on crimping logic wiring.

Company: SUNFINE DYNAMIC LTD August 2013 – February 2014

PROJECT: LOT 1 CALABAR POWER STATION, NIGERIA

CLIENT: NATIONAL INTERGRATED POWER Plant (NIPP)

POSITION: INSTRUMENT SUPERVISOR

Job Description.

Installation of Jockey pump panel and complete wiring

Trouble shooting of fire Detection and Alarm system.

Material inspection from vendor packages.

Perform COLD and HOT loop check using project approved drawing.

Interfacing GE vendor in loop checks and Calibration.

Perform trouble shootings, including preventative and corrective maintenance.

Good knowledge of mechanical relation to valves.

Company: ALCON NIGERIA ltd March 5 /2011- July 20/ 2013

Project: Idu Flow Station Phase 2

Client: NIGERIA AGIP OIL COMPANY (NAOC)

Position: INSTRUMENT COMMISSIONING/CALIBRATOR

Job Description.

A well-grounded experience on instrument calibration.

TYPE OF TEST EQUIPMENT AND MANUFACTURER SO FAR USED.

Dead weight tester BUDENBERG

Digital multimeter FLUKE

Hart communicator MERIAM

375 hart communicator EMERSON

Hart communicator FISHER-ROSEMOUNT SYSTEM

Pressure calibrator DRUCK

Current generator 4-20mA FLUKE

24V,D.C & 110V, D.C supply THANDAR & PERSONAL BUILD

Temperature Calibrator FLUKE

Air Compressor POWER FLEX

Temperature batt AMETEK.

TYPE OF INSTRUMENT CALIBRATED AND MANUFACTURER.

Transmitter ABB,ROSEMOUNT,YOKOGAWA and MICRO-MOTION

Pressure gauges WIKA and NOUVA FIMA

Temperature gauges WIKA and NOUVA FIMA

Level Switch high high & low low PONTERANICA

Level transmitter MAGNETROL MASONEILAN

Temperature Element ROSEMOUNT and LIMATHERM

Solenoid valves ASCO,BIFOLD,MAXSEAL,VERSA,& FALCON

I/P converter/controllers ABB and ECKARDT

Pressure switch high high & low low PRESSOSTATO,UE,BARKSDALE,NEO-DYN and DWYER

Vibration switch DEMKO,METRIX and ROBERTSHAW

Actuator valve ROTORK,MASONEILAN and VALVITALIA

Control valve FISHER,MASONEILAN and EKARDT

I led calibration team in this project on areas like scrubber skid and solar gas turbine (package).

Pre-commissioning of injection sub-station, circuit breakers, relays, motors sub-station, earthing system and fault analysis.

Commission and operation of compressors, steam turbine, boilers, heaters, dryers, nitrogen and cooler fans.

Ability to stroke a valve in local control panel (LCP)

Ability to interpret instrument data sheet before calibration.

Installation of distribution control system(DCS),Instrument junction boxes(IJB),Local control panel (LCP) Air distribution,transmitter,pressure switch and pressure gauges

Tube bending, cable laying, glanding, Termination of cable in DCS panel, UPS panel, LP panel, MP panel, Fuel and gas panel and Operator Console.

Good knowledge on Analogue output/inputs cabling screens and signals.

Good knowledge of mechanical relation to valves.

Process knowledge of oil treatment, gas treatment and heating.

Physical measurement and ability to understand the relation between C and Kelvin by temperature, PSI and BAR by pressure measurement.

Good knowledge on loop diagrams (SOLAR TURBINE, DCS, and marshalling panels to field devices.

Involve in pre-commissioning and commissioning activities like cool loop, hot loop and troubleshooting of field instrument.

Wiring diagrams and logics

Ability to work in a confine space like solar turbine.

I was opportune to work with so many vendors like SOLAR, FORESS, SIEMENS, and DRESSER RAND.

Company: ALCON NIGERIA LTD July 2010 to Dec 2010.

Project: Ubie Integrated Oil & Gas, Gbaran (FLB)

Client: SHELL PETROLEUM DEVELOPMENT COMPANY NIGERIA (SPDC).

Position: INSTRUMENT/ELECTRICAL TECH

Job Description.

Installation of instruments as per P&ID and location drawings.

Glanding and termination of instrument cables inside junction box and instrument.

Maintenances of Transmitter, Converter, Temperature Element, Controllers, solenoid valves, pressure switch, valve positioner, level switch, recorder, etc.

Cool and Hot loop check using the approve drawings.

Perform trouble shootings, repair and maintenance including preventative and corrective maintenance.

Instrument equipment hook-up

Strictly follow the safety quality.

DAEWOO NIGERIA LIMITED BAYELSA April 2010 to July 2010

Client: AGIP Nig Ltd

Project: Oboinbiri flow station upgrade and gas gathering for LNG Train 4/5

Position: INSTRUMENT COMM/CALIBRATOR TECHNICIAN

Job Description

Calibration, loop check and commissioning field devices.

Stroking of valves

Material inspection from vendor packages.

Interpretation of P&ID and hook-up.

Control panel installation.

Maintenance and troubleshooting of field devices

NATIONAL YOUTH SERVICE CORP (NYSC) TEACHING MATHEMATICS and PHYSICS; Ogboin Comprehensive High School Agbia/Nedugo BAYELSA STATE.2009/2010

INDUSTRIAL TRAINING; Iron and steel Group ltd BAO YAO HUAN JIAN CHINISE COMPANY Calabar Cross River State.

Installation and maintenance of electrical and instrument devices.

PERSONAL QUALITIES AND SKILL

Innovation, Hardworking, Honest, obedient, Humble, and Skilful.

PROFICIENCY

Proficient in Microsoft packages such as MS Word, MS Excel, Power point, AutoCAD.

HOBBIES

Charting, listening to music reading and football.

REFEREES

MR PETER OHIERO

Lecturer; Department of Electrical / Electronic Engineering CRUTECH Calabar.

MR PHILIP ODEY

Chief Technologist Department of Electrical / Electronic Engineering CRUTECH Calabar.

SUR. RAPH UCHE.

Ministry of land and Housing Cross River State.



Contact this candidate