Post Job Free
Sign in

Electrical/ I&E/ I&C tech

Location:
Myrtle Beach, SC
Posted:
December 04, 2015

Contact this candidate

Resume:

Luther Kevin Atkins

** ***** **** ******** *.C **431

910-***-****

SUMMARY OF SKILLS

1.Accustomed to working in fast paced and demanding environments

2.Follows instructions well and able to work with little or no supervision.

3.Motivated to learn new methods and tasks

4.Dependable

5.Safety conscious and Oriented

6.Honest and trust worthy

WORK HISTORY

3/23-5/25. HB Robeson Nuclear Plant. Electrical/ I&C tech. Worked with other techs on replacing radiation monitors throughout the plant. Determed wiring from old monitor's and inspected for any damage. Installed anchors and unistrut for new monitor's. Terminated wiring

In new radiation monitor's and terminated conductors in the control room.

11/2014- 3/2015. Brunswick Nuclear Plant. Electrican. Worked on the flex diesel fukushima

project. Installed cable tray, 4 inch ridgid conduit. Pulled cables and terminated wires in the switch gear. Installed hangers, mounted boxes. Worked with the turbine lighting group. Replaced all lighting hardware with new led lights and hardware.

9/2014-11/2014 Duane Arnold Nuclear plant. I&E tech. Installed temp power through out the plant. Inspected and cleaned 4160 switch gears. Tested and calibrated various transmitters and rtds. Inspected and calibrated relays and breakers. Pulled wire into control cabinets and terminated control wiring. Terminated wires in dcs cabinets. Helped with the calibration of fisher valves and setting up of the testing equipment. Stroked and terminated valves. Helped plant techs with the loop checks. Worked with plant techs on the setting up and conducting performance test on plant equipment.

7/2014-9/2014 North Anna Nuclear Station. Mineral Virginia. I&E. Worked with plant techs on control panels and wiring. Terminated and determed transmitters and limit switches. Pulled wire and installed rtds. Installed and calibrated control devises and other technical equipment.

11/2013-4/17 Brunswick Nuclear Station. Southport, NC. I&C tech. Helped senior techs set up and program testing equipment. Programed panametrics and other data collecting equipment. Setup vibration monitoring equipment and collected data. Recorded data from Rtds at various power levels. Stroked and terminated valves. Helped with loop checks. Helped plant techs setup and conduct performance test on equipment.

5/2013- 11/2013 Oconee nuclear station, Seneca S.C. I&C. Tech. Worked on the Reactor protection system and engineering safe guards (RPSES) outage. Determed and removed all the wiring in the existing DCS cabinets. Placed new Areva digital cabinets and terminated new wiring. Reviewed work orders, procedures, and technical documents in advanced so they could be corrected by the appropriate personnel. Peformed walkdowns and reviewed blue prints.

4/2013- 5/2013 Invistia Camden S.C. I&C tech. Mundy Companies. Worked with other techs on the overhaul and calibration of Flowserve-valtek control valves and Hammel Bahl valves. Installed and terminated limatorque valves. Installed and calibrated Rosemont transmitters and various gauges. Installed thermocouples and Rtds. Cleaned and inspected breakers and 4160 switch gears. Worked in dcs cabinets and helped perform and setup testing equipment. Worked in plc cabinets. Helped with control loop testing

5/2012- 4/2013 McGuire Nuclear station, Huntersville N.C. Electrican. Worked with major projects doing different tasks such as wire pulls, hanging cable tray, running 3/4 to 1 inch emt conduit. Mounted transmitters and electrical boxes. Worked on the unit 2 generator and exciter outtage fall 2012. Terminated Cables on the generator and exciter. Helped with the efa project. Mounted pull stations, horns, and strobes. Terminated the heads and panels.

2/2012- 5/2012 Oconee Nuclear Station Seneca, S.C. I&C. Tech. Worked on the Reactor Protection system and engineering safe guards (RPSES) outtage. Determed and removed all the wiring in the existing DCS cabinets. Placed new Areva digital cabinets and terminated new cables. Mounted panels and pulled cables. Peformed walk downs, reviewed work orders, procedures, and blue prints.

2/2011-2/2012 Dak Americas, Leland NC. I&E tech. Mundy Companies.Worked on various types of lighting systems for the plant. Pulled wire, terminated motors and controls. Mounted and terminated transmitters and rtds. Helped with the overhaul and calibration of Flowserve-Valtek control vaves and Hammel Bahl valves. Worked extensively in dcs cabinets and helped setup testing equipment and performed test. Helped with loop tests. Worked with the plant loto team and made sure all equipment was locked and tagged before any work began.

6/08-12/2010 Atlantic group, Raeford NC. I&E tech. North Carolinas first ethanol plant. Installed new MCCs, transformers, switch gears, duct bank. Ran conduit and cable tray. Pulled miles of cable. Mounted and terminated over a 1000 transmitters. Terminated lights and lighting panels. Terminated motors and controls. Installed Ozzy and Field bus systems. Helped with Loop

checks and setting up the testing equipment. Installed and worked in plc cabinets.

2/2006-5/2008 Dak Americas, Leland NC I&E tech. Mundy Companies. Worked on the resins project. Installed conduit and cable tray on new finisher. Installed and terminated new lights and lighting panels. Terminated motors and controls. Worked in DCS cabinets Extensively. Helped with the overhaul and calibration of Flowserve-valtek control valves and Hammel Bahl valves.

Installed and calibrated control devises and conducted performance test on equipment. Worked in plc cabinets.

EDUCATION:

1995- Graduated West Columbus high school.

2002- Southeastern community college. Electrical electronics

REFERENCES AVAILABLE UPON REQUEST



Contact this candidate