Post Job Free
Sign in

Electrical Engineer Project

Location:
Calgary, AB, Canada
Posted:
June 30, 2014

Contact this candidate

Resume:

MD SHAHNAWAZ ANJAN

*** ********** **** **, *******, AB T3J3W1

403-***-**** (Cell), *****.******@*****.***

HIGHLIGHTS OF EXPERIENCES:

. 10+ years of experience in Relay protection & control engineering

including detailed design for medium to high voltage substation and

transmission projects through 500kV.

. Development of protection and control philosophy/logic from system and

section point of view.

. Skilled in designing Transformer, Bus, Line protection & Breaker

control using both Electro-mechanical and Microprocessor based

numerical Relay.

. Well acquainted with single line and three line diagram of substation

and Annunciation.

. Experience in designing system with numerical relays: SEL, GE, ABB,

Siemens, Basler, Beckwith, Areva, etc.

. Familiar with relay selection and co-ordination study.

. Proficient in ETAP, Micro Station, AutoCAD, MS Office, MATLAB.

. Familiar with detail wiring design in AutoCAD Electrical environment.

. Consistence in analytical problem solving, strong communication

skills, self motivated and result oriented.

EMPLOYMENT HISTORY:

P&C Technical Professional March, 2012 to Present

SNC Lavalin, T&D. 300, 640 5th Avenue, Calgary, AB T2P3G4

. Completed Single line, Control Single line, three line diagram, DC

Logic and protection schematic of Foothills-237S with 6 BKR and 4 Line

(240KV), 4 BKR and 2 Line (138KV), 2 240/138kV 240/320/400MVA

Transformer and SPS with two 240KV Line that has Series Capacitor

Bank(SCB).

. Prepared and develop Single line, Control Single line, three line

diagram, DC Logic, protection schematic and wiring diagram of 240KV

(50+50) MVA Jackfish Substation for Altalink from DBM to As-Record

stage.

. Designed DC Logic, protection philosophy and schematic of 240KV (1090L

& 971L) line for Jackfish SS.

. Redesign Anti-Islanding philosophy for Christina Lake and Conklin

Substation as per DBM.

. Incorporate LV feeder protection with Substation protection and wiring

of prefabricated Control Building.

. DC Logic and Internal wiring check of Sunny Brook and Fidler

Substation as per DBM.

. Developed and reviewed technical specifications and standards of major

equipments.

. Coordinated and reviewed design activities with other project team

members.

. Maintained complete project documentation, all design packages, as-

built and return data information for newly energized 50MVA XFR in

Christina Lake 723S.

Electrical Engineer Nov, 2011 to March, 2012

Unit Electrical Engineering Ltd.

1406 Maple Street, Okanagan Falls, BC V0H 1R2

. Prepared conceptual design and develop Single line, three line diagram

and protection schematic of 5MVA mobile substation for Quintette

Project of TECK COAL LTD.

. Designed protection schematic of generators, transformer, circuit

breaker, and other electrical layout of movable generator for CUMMINS

WESTERN CANADA LTD.

. Performed Load flow, Short circuit analysis, and Protective device

coordination study using ETAP of Copper Mountain Mobile Substation

Project of SIMILCO MINES.

. Evaluated the selection criteria of equipment/material and prepared

specifications for material/equipment and construction/installation

scope of work.

Electrical Engineer June, 2011 to Oct, 2011

DMX Plastics, 200 Hymus Rd, ON M1L2E1

. Supervised the production of corrugated pipe and dimpled plastic sheet

for humidity and damp control in modern building.

. Performed trouble shooting of MCC, panel board design, A/C, D/C Motor,

Conveyer System.

. Developed equipment stocking strategies in order to improve

Maintenance Plan continually to minimize downtime and maintenance

cost.

Electrical Engineer Aug, 2000 to Aug, 2008

Rural Electrification Board, Bangladesh,

. Designed substation including site plan, equipment layout, single line

diagram, control diagram, protection and metering schematic.

. Selected the size of transformer, generator, motor, breaker, CT, PT,

contactor, fuse, capacitor and metering unit for individual

customer/load.

. Calculated the cable size on the basis of de-rated FLA, voltage drop,

short circuit capacity.

. Designed substation grounding and also the individual load grounding.

. Prepared data and drawing requirement, inspection and testing

requirement, scope of supply for the construction of substation.

. Designed the bus/transformer differential protections, breaker

failure, over-current, earth fault, restricted earth fault, under and

over voltage protections.

. Analyzed electrical system in terms of earth fault, short circuit

fault, load flow capacity.

. scrutinized tender documents and evaluated the bids, selecting and

reviewing vendors.

. Estimated Man-Hour for each project work.

. Coordinated design activities to maintain project schedules and

ensured successful project completion.

Design Engineer (Electrical) Aug, 1996 to May, 2000

Paradise Cables, Bangladesh

. Designed the HV, MV LV and Cable control cable as per customer

requirement

. Performed the voltage drop calculation for different structure of

insulation, armouring and sheathing.

. Carried out testing of HV Cable according to BS standard.

EDUCATION:

2011 - MASc, Concordia University, Montreal, Quebec, Canada

1995 - B.Sc, Bangladesh University of Engineering and Technology,

Dhaka, Bangladesh

PROFESSIONAL AFFILIATIONS:

. APEGBC or APEGGA(Alberta) Eligible

. Institute of Engineers, Bangladesh 1998

REFERENCE: Upon Request



Contact this candidate