Post Job Free

Resume

Sign in

Engineer Power Plant

Location:
United Arab Emirates
Posted:
May 12, 2014

Contact this candidate

Resume:

[pic]

LUISITO B. LIWAG

e-mail : acd28k@r.postjobfree.com

acd28k@r.postjobfree.com

Home Address : *** *****, ********** ****,

Philippines

Work Address : IGD 5 Habshan, Abu Dhabi, UAE

Contact Nos. : +971-********* (UAE) +639*********

POSITION DESIRED : Electrical Test Engineer

Electrical Engineer

Electrical Maintenance Supervisor

INDUSTRY TYPE : Oil and Gas

Power, Energy and Utilities

Functional Area : Construction, Engineering, Production

Maintenance and Quality

A. CAREER SUMMARY

> BS Electrical Engineering Graduate (1981)

> Registered electrical Engineer (REE No. 19128)

> More than 25 years of practical experience in

Installation, T&C, Maintenance and Operation

> With full understanding and practical experience in pre-

commissioning, start-up, troubleshooting, preventive

maintenance and operation of electrical equipments in a

modern day power plant.

> Capable of using different type of electrical test

instruments such as primary and secondary injection kit.

Insulation resistance tester, multimeters etc.

> With proven skills in troubleshooting of complex

electrical control system.

> With knowledge in International Standards

> Capable of reading and interpreting different types of

electrical drawings and diagrams

> Familiar with MS Office applications(Word & Excel)

B. WORK EXPERIENCE (October 20, 2011 - present)

Company : Hyundai Engineering and Construction

IGD 5 Habshan Utilities and Offsite Project

Habshan, Abu Dhabi, UAE

Position : Testing and Commissioning Engineer

Job Description of Testing and Commissioning Engineer

Prepare and update commissioning activity schedules, site

observations, site visit reports among others.

Review, amend and approve T&C method statement in accordance with the

International Standards, Project Specification, Local Regulation and

Manufacturer's Recommendation.

Specific Description of Work of T&C Engineer

> Verify and witness T&C of all electrical equipments such as

HV/MV and LV switchgears, AC/DC UPS panels, Battery banks,

electrical control system and Integrated protection and control

system (ECS and IPCS)

> Set up, operate test equipment to evaluate the performance of

electrical components, assemblies or systems under simulated

operating condition and record the results.

> Analyse and Interpret test report to determine any acceptable

and unacceptable results and design related problems.

> Provide technical assistance and resolution when electrical

and/or engineering problems are encountered during testing and

commissioning.

> Collaborate with other Electrical Engineers of the client and

other key personnel to identify and solve the problems

> Conduct periodic site inspection for QA and QC programs. Repor

the findings and recommendations.

> Adhere to safety rules and regulations of the company to avoid

accident at worksite. Conduct tool box meeting every start of

the work to caution the workforce of all the potential danger in

the worksite.

PREVIOUS EMPLOYMENT (27 February 2009-02 March 2011)

Company : Hyundai Engineering & Construction

LP-251 Sarir Power Plant

General Electricity of Libya (Gecol)

Sarir, Libya

Position : Electrical Test Engineer

SPECIFIC DESCRIPTION OF WORK

> Carry out inspection and test for various electrical equipment

such as transformers, circuit breakers, HV/LV switchgears and

other electrical equipments in the presence of the clients.

> Performs pre- functional and functional testing of various

electrical equipments and accessories to make sure that the said

equipments are really operational.

> Performs line test, insulation resistance test, hi potential

test, and continuity test on Isolated phase bus (IPB), non

isolated phase bus (NIPB), all power cables and control cables

to make sure that all the terminations are all correct.

> Performs various tests required for CT's and VT's.

> Prepares test report and documents for the particular test

performed.

> Make sure that all works done complied with IEEE /IEC standards.

> Coordinates with ABB and Siemens group regarding the settings

and other pertinent value/data of the relays that are being used

in our system.

> Performs other tasks that maybe assigned to ensure the proper

operation of the power plant.

PAST EMPLOYMENT: (Dec 2006 to Nov. 2008)

Company : Saudi Electricity Company

Main Distribution Network Operation

Department

Operations Network and Control

Division

Al Jouf Power Plant

Doumat Al Jandal, Al Jouf, KSA

Position : Power Dispatcher, Network Control Centre

SPECIFIC DESCRIPTION OF WORK

> Shift coverage to monitor and control 132 kV and 33 kV Network

System.

> Prepare planned and unplanned switching steps. Isolate

equipments for working personnel.

> Analyse system failures, relay targets and alarms of equipment

tripping and take necessary action to restore the power and plan

to prevent the re-occurrence. Notify the management and prepare

the interruption report.

> Monitors and controls the operation of AL JOUF power systems via

SCADA (Foxboro Work Station Computer) whether during

normal or abnormal operating conditions.

> Coordinates on a real time basis, with the power generation

group to meet the daily forecasts demands, directs the running

hours of the On-Line generating units to ensure that electricity

is produced as economically as possible to meet system's demand

requirement with the required spinning reserve.

> Initiate necessary and proper corrective actions to stabilize

and restore power system back to normal state following a system

disturbance. Giving primary attention to system abnormalities

such as lines and/or power transformers protection trippings to

restore power to the affected customers in the shortest time

possible.

> Coordinates all scheduled and unscheduled maintenance outages

with the concerned maintenance personnel. Implements step by

step switching procedures in a way that eases the operation of

the entire power system.

> Implements proper load management control action when necessary

to compensate generation deficits such as the prepared manual

load shedding schemes.

> Maintains a narrative log of all events during normal and

abnormal operating conditions that could affect directly or

indirectly the power system.

> Complete the daily dispatcher log with the activities performed.

> Periodically go through the system's historical records and

update it.

> Maintain the system's voltage at its desirable level

PAST EMPLOYMENT (September 1996- November 30, 2006)

COMPANY : CABANATUAN ELECTRIC CORPORATION

POSITION : Substation Supervising Engineer

DUTIES & RESPONSIBILITIES

> Part of the pioneering team that conceptualized and constructed

the company's two 25 MVA 69 / 13.8 kV, 60 Hz. substations.

Subsequently became a part of the group that operated and

maintained the said substations.

> Directs the Operation and Maintenance of power station with

three step down transformers rated at 13.8kV/480-220VAC.

> Responsible for the operation of two emergency generating units

with the following specified capacity of 2.5MVA and nominal

output of 480VAC.

> Periodically performs an insulation resistance test to all

power cables as a preventive maintenance measure.

> Carry out periodic switchgears inspection and participates in

conducting preventive maintenance of station service equipments,

this ensures the availability of power supply in case of

unforced and scheduled outages.

> Coordinates with the Maintenance Engineer during test/repair

operation of switchyard equipments.

> Logs and analyses all abnormal events such as major outages and

other system disturbances to be able to prevent future

occurrence of such problems.

> Initiates shutdown during extreme emergency and protective

equipment failure, and coordinates with the line crew Supervisor

during switching and tripping operations to ensure safety.

COMPANY : CABANATUAN ELECTRIC CORPORATION

POSITION : Transmission Lineman / Electrician

EMPLOYMENT DATE May 01,1993-September 01,1996

DUTIES AND RESPONSIBILITIES

> Part of the team that maintains, and installs pole mounted

distribution type transformer for consumers use.

> Performs lineman's job which includes stringing of primary

and secondary lines, installation of transmission line

accessories, erection of concrete and wooden poles, clearing

of line hazards and other job that is related to transmission

line construction.

> Also perform troubleshooting works especially during bad

weather condition, when our presence are badly needed.

PAST EMPLOYMENT (August 24,1982-September 01,1991)

COMPANY : BENGUET CORPORATION

Dizon Copper Operation

San Marcelino, Zambales

POSITION : Lead Electrician

DUTIES AND RESPONSIBILITIES

> Leads a group of electricians who performs troubleshooting,

repairs and preventive maintenance on all electrically driven

motors and equipments, necessary for the mining and milling

operations.

> Knowledgeable in repair of trailing cables and couplers,

outdoor type switchgears, and other mining related equipment.

> Responsible for the Operation and Maintenance of two 1000kW,

4160V,60 Hz. mobile Generating Units required in transporting

the Power Shovel or Power Drill within the mining's pit area.

> Assists in other undertaking that concerns electricity to

ensure the uninterrupted and trouble free operation of the

mining company.

TRAININGS AND SEMINARS ATTENDED

SEMINAR TITLE TRAINING CONDUCTED BY DATE

Power Plant Training First Cabanatuan Ventures Corp. Mar 4

to Sept.16, 1996

Cabanatuan City

Protective Relaying Inst. of Integrated Elect'l Engrs.

Sept. 20 and 21,1996

IIEE National Chapter

Transformer Selection Inst. of Integrated Elect'l Engrs.

Aug. 23 and 24,1996

and Maintenance IIEE National Chapter

Substation Maintenance Inst. of Integrated Elect'l Engrs.

June 28 and 29,1996

IIEE National Chapter

Elect'l Safety Practices Inst. of Integrated Elect'l Engrs.

April 27,1991

IIEE Olongapo City Chapter

Fire Prevention and Benguet Corporation Feb.1

and 2,1988

Protection San Marcelino, Zambales

First Aid Training Benguet Corporation

October 1986

San Marcelino, Zambales

PERSONAL DATA

Birthday : January 28,1961

Birthplace : Mandaluyong, Metro Manila

Citizenship : Filipino

Religion : Roman Catholic

Sex : Male

Height : 5 feet 8 inches

Weight : 160 pounds

Complexion : Fair

Civil Status : Married

Name of Wife : Marilou Daniel Liwag

Address : #254 Prk. Sampaguita, Pagas,

Cabanatuan City, Nueva Ecija 3100

Philippines

Number of children : Three (3)

Names of children : March Pamela Angeline

March Pierre Angelo

March Joshea Venice

Name of Father : Jose R. Liwag (deceased)

Name of Mother : Felicisima Bernardo-Liwag

Language : English and Tagalog

Passport No. : XX3350494

Issued at : DFA Consular Office,

Clarkfield, Pampanga, Philippines

Date of Issue : 27 March2009

Valid Until : 28 March2014

EDUCATION

Degree Holder :

Bachelor of Science in Electrical Engineering

Nueva Ecija University of Science and Technology

(Formerly - Central Luzon Polytechnic College)

Cabanatuan City 3100 Nueva Ecija

Philippines

OTHER SKILL/S

Knowledgeable in Computer such as MS Office including Excel and PPS,Vehicle

Driving, Athletic Enthusiast.

LUISITO B. LIWAG

Applicant's Signature



Contact this candidate