Career Objective
PERSONAL DETAILS With an experience in the field of Testing and Commissioning of
Transformers, I look forward for an opportunity to display my
Name : B.VELMURUGAN skills in the field of Testing & commissioning, Maintenance and
Execution of projects related to transformers and Alternators.
Date of Birth : 09.05.1987 Educational Qualification
B.E. (ELECTRICAL & ELECTRONICS ENGINEERING)
Nationality : Indian Anna University),Class : First class, Course type : Full time
Year of passing : 2009
Sex : Male
PRESENT EMPLOYER : VOLTEC ENGINEERS PVT LTD, CHENNAI
Designation : Sr. Testing and commissioning
Engineer
Work Experience : 4 Year 1 month
PASSPORT DETAILS:
Skill Set
Passport No. : J5772226 Testing and commissioning of all Electrical equipment from 415
Place of Issue : CHENNAI volts to 400 KV & 765 KV System.
Date of Issue : 30.05.2009 Annual Maintenance of testing CB, T/F, CT, PT,LA and Motor
Expiry Date : 29.05.2021 Control and Protection scheme checking in
Knowledge about protection scheme such as Differential,
Overall differential, REF, Over current, Bus bar differential,
Email id: Distance protection.
*************@*****.*** Quickly adaptive and expertise in new and emerging
Technologies.
Nature of work
Contact no: Testing & Commissioning :
+919********* Testing and commissioning of 415V to 400KV Indoor / Outdoor
+919********* substation and substation equipment's.
Power Transformers of capacity 350MVA and above & station /
Distribution Transformers.
Address: Testing & Commissioning of Static and Numerical Protection
Relays of various types of leading makes.
S/O.R. BALASUBRAMANIYAN, Indoor and outdoor substation and substation equipment's with
36, SATHAPADI STREET, all type of switchgears SF6GCB, VCB, MOCB, ACB's.
CHIDAMBARAM All type of protection relays, of leading makes of static and
CUDDALORE - 608001. microprocessor based relays.
Maintenance testing of relays, Breaker and calibration of Elec.
Meters.
Preparation of cable schedule and termination schedules.
Trouble shooting of various electrical system at different type
of process Plants and power plants.
Testing and calibration of all meters.
Some of the jobs which were executed by him successfully are
briefed below :
Testing & commissioning of 220 kV Switchyard for 195 MW
Combined Cycle Gas Power plant, Samalkot including Protection,
cable schedule preparation, control scheme preparation &
overall scheme checking through M/s. BSES Ltd., Hyderabad & EPC
Division, New Delhi
Testing & commissioning of different Electrical equipments such
as CTs, PTs, Circuit Breakers, Isolators, Protection Relays
LANGUAGES KNOWN: Protection, overall scheme checking, Cable Schedule preparation
and as-build drawing preparation for 220 KV Substation and its
Tamil, English and Hindi protective relays for RTPS, Raipur through M/s. ABB Ltd.
Testing & commissioning of Electrical equipments such as CTs,
PTs, Circuit Breakers, Isolators, Protection Relays and overall
scheme checking of 400 / 220 / 33 KV Substation and its
protective relays at Kolar Karnata for CGL Ltd
Testing & commissioning of Electrical equipments such as CTs,
PTs, Circuit Breakers, Isolators, and overall scheme checking
of 110 / 11 KV Substation and its protective relays for TELK at
Karaikal, Tamil Nadu
Testing & commissioning of Electrical equipments such as CTs,
PTs, Circuit Breakers, Isolators, and overall scheme checking
of 132 / 33 kV Substation (4 nos) and its protecting relays,
for APTRANSCO through M/s. BSES Ltd.
Testing & commissioning and overall scheme checking of 66 / 33
KV Substation equipments such as CTs, PTs, Circuit Breakers,
Isolators and its protective relays for Alstom Ltd, Delhi
Testing & commissioning and overall scheme checking of 33 / 11
KV Substation equipments such as CTs, PTs, Circuit Breakers,
Isolators and its protective relays for Siemens Ltd, Delhi
Testing & commissioning and overall scheme checking of 21 KV /
415 V Switchgear equipments such as CTs, PTs, Circuit Breakers,
Isolators and its protective relays for Alstom Ltd, Himachal
Pradesh
Testing & commissioning and overall scheme checking of 132 / 33
KV Substation equipments such as CTs, PTs, Circuit Breakers,
Isolators and its protective relays at Raipur, Chattisgarh for
EMCO Ltd
As a power performance tests
Vibration analyzing of rotating &static machine
Noise measurement of reactor, generator, motor etc
Power analyzer of motor energy consumption, transformer etc
Thermo vision analyses of transmission conductor joined(using
27mm lens Flir systems E-300)
Harmonic Analyzes
Hi-Pot testing of cables and Bus bars
Dew point check of Sf6 breakers and rectors, Transformer's and
cylinder
Co-ordination with client in As Built Scheme drawing
submission, test report submission and co-ordination during all
site activity to satisfy the customer
As a sweep frequency response analyzer (SFRA)
Analyze the transformer and reactor physical condition:
winding to winding distance, winding to tank distances, buck
hooking, winding to winding short, oil factor, bushing
tightness, winding displacement winding deformation,etc(315
MVA transformer,50MVAR,80MVAR reactor etc (using DOBLE M500kit)
and Megger.
As a Testings transformer's upto 315 MVA
Ratio test
winding resistance upto 60Ampere (using Tinsley,scope, Eltel)
Magnetic balance& magnetizing current
vector group
Polarity check for single Phase transformers
break down voltages for transformer oil
separate source voltage test
PI&IR value test
floating neutral test
short circuit test
% of impedance measurement.
Surge comparision analyzer of CT 3 phase coils
HHHhhhhhhhHHHHHHigh voltage Capacitance and Tan delta
measurement
As a Capacitance& Tan Delta Measurement (C&DF)
CT, CVT, PT, IVT, Coupling capacitor, Upto 315 MVA
transformer, shunt and Bus reactor, motors, Generator
capacitance and Tandelta measurement Upto 10,600KVA,Upto 765 kV
Grading capacitance check,Surge arrester upto 400kV and
Temperature correction factors are applied (using ELTEL and
DOBLE M4000 kit, Megger kit )
As a Testing Done For CT'S, CVT, PT'S, Surge Arrester &
Isolator Switches
Insulation Resistance Measurement
Winding Resistance Test
Knee Point Voltage and excitation measurement
Ratio Test
Polarity Test
Stability Test
Surge Comparison Analyzes for CT 3 Phase Coils
Surge Counter Check for Surge Arrester
Static contact resistance check(CRM)
Experience with ALSTOM RELAYS
Micom P442- Distance protection
P630 - Transformer Diff.Protection
Micom-P343- Generator Protection
Micom127- Directional O/C & E/F Protection
Micom121,111 O/C & E/F Protection
Experience with ABB Relays
REL521- Line Protection
REM543, REM 545, - Generator Protection
RET 521,RADSB,-Transformer Diff.Protection
REX 521, SPAJ140-C, REJ521 - O/C & E/F Protection
Experience with SIEMENS Relays
7SJ6005,7SJ6225-O/C & E/F Protection
7UT612- Transofrmer Diff.Protection
CT & CVT Testing
Auxiliary Relays testing
Backup relay testing
Primary injection up to relay end.
Bus bar & Transformer sensitivity & stability test
DC scheme check
Trip coil supervision Circuit & Current measurement checks
Trip logic checks
CB fails functional checks
Secondary injection
Meter calibration
Out going feeder identification
REF - Sensitivity & Stability test
As a Maintenance Engineer
Maintenance of electrical equipments like Circuit breaker,
Transformer, CT, PT, CVT, LA, Isolator and battery charger.
Preventive Maintenance for HT and LT Motor
Experience
EXPERIENCE SITE DETAILS
Project : 2*600 Mw Udupi Power Cor. Limited
Client : M/s. Lanco. Limited
Customer : UPCL, Udupi, KA
Project : 1200 KV,SUB STATION
Client : M/s. SAEE TRAFO LINE PVT.LTD
Customer : PGCIL, BINA, UP.
Project : 400/220 KV Sub Station
Client : M/s. Techno Electric and Engineering Co. Ltd
Customer : PGCIL, Jaisalmer, Rajastan
Project : 220 KV Sub Station
Client : M/s. Larsen & Toubro Limited
Customer : Tatweer Petroleum, Bahrain, Kuwait
Project : 220/33 KV Sub Station
Client : M/s.ABB. Ltd
Customer : PGCIL, Maithan,WB
Project : 1*500 MW KSTPP
Client : M/s. Techpro System Ltd
Customer : NTPC, Korba, CH
Testing & commissioning of 400KV Substation, Testing of CT, PT,
Breaker, Isolator & Transformer and motor protective relays,
Cable schedule preparation for NTPC at Simhardi, Andhra Pradsh
.1
Operation & Maintenance of 400KV & Switchyard control room,
500 MVA Power Transformer & 16 MVA Unit Transformer & its
Auxiliaries at JSW ENERGY (Bellary) Karnataka. and NTPC, 1*500
MW,Korba,CH
Declaration
I consider myself familiar with Electrical and Electronics
Engineering Aspects. I am also confident of my ability to work
in a team.
I hereby declare that the above-mentioned information is
correct up to my knowledge and I bear the responsibility for
the correctness of the above-mentioned particulars.
Thanking you.
Place: chidambaram
Date:
You're truly
B.VELMURUGAN