Post Job Free

Resume

Sign in

Electrical Engineer

Location:
Perambalur, Tamil Nadu, India
Salary:
1200
Posted:
July 18, 2019

Contact this candidate

Resume:

Prakash.G

*-***, *-***,*********** east street,Karadichithur 606207

Mobile: +91-950******* E-Mail: ac9umg@r.postjobfree.com

Electrical Supervisor Electrical Chargehand

A competent result-driven engineering professional with over 10 years experience mainly in Project management,Oil & Gas industry. Seeking a challenging assignment as a Electrical Supervisor in a reputed firm

Proactive decision maker, targeting challenging and senior managerial assignments with a well-established and globally reputed organization, bringing the following technical strengths:

HT / LT Transformers O&M

C Licenced holder-Govt of Taminadu

Electrical maintenance

Generators O&M

HV/LV substaion shutdown

Preventive maintenance

Compressor O&M

PLC programming

Industrial Machinery & controllers

STP O&M

Turnaround Facility

Electrical breakdown & shutdown

EXECUTIVE SYNOPSIS

Possess quick decision making abilities and leadership qualities, with ability to work efficiently in demanding work environments to meet deadlines.

Proven track record of finishing the projects within time and

according to project plans

Remarkable ability to effectively implement and accomplish assigned tasks in a timely manner without sacrificing quality.

Effectively managing multicultural teams and working tirelessly and diligently to achieve company goals.

Excellent critical thinking skills to identify alternative approaches and solutions to complex problems.

Excellent internal and external communications skills.

Experience of preparing and maintain track records of integrated systems

Adhering to Electrical“Standard Operating Procedures.

PROFESSIONAL WORK EXPERIENCE

Powerlynx (NOCL), Cuddalore

Electrical supervisor, Feb 2017 to Present

(Reporting to Electrical Engineer & leading team of 15)

Design, test and troubleshooting of Automation system, Controls, electronics and Electrical systems

Programming of PLC and SCADA.

Set perimeter Communication Serial port & 4-20 mA /0-5 V

I/O control relay outputs

Set up control panel troubleshooting of motor Controls, various starters.

Good knowledge of troubleshooting of power Distribution Circuits, Motor Control Panels, Variable

Frequency drives.

Well versed with automation (Closed loop Controls, PLC, Systems)

Experience in termination and laying of power and control wiring.

Good knowledge in Diagnostic using multi meter.

PLC and Delta V upgrades

Motor and motor control preventative maintenance and mechanical integrity

Instrumentation preventative maintenance and upgrades

Lighting upgrades

De-energized electrical maintenance.

High-voltage injection testing.

Insulation testing.

Contact resistance testing.

Visual inspections.

Service updates.

Al nasr contracting Co., LLC, Abudhabi, UAE

Electrical charge hand, July 2014 to Aug 2016

(Reported to Electrical Engineer & leading team of 20)

Able to Understand Construction and Technical Drawing.

I/O control relay outputs, Experience in termination and laying of power and control wiring.

Inspection of Electrical Installation works.

Test and Troubleshooting of Automation system, Controls, electronics and Electrical systems

Good knowledge of troubleshooting of Motor Control Panels, Variable Frequency Drives.

Experience in switching operation to isolate restore required equipment

Set perimeter Communication Serial port & 4-20 mA /0-5 V.

Well versed with automation (Closed loop Controls, PLC, Systems.

Set up control panel troubleshooting of motor Controls, various starters

Experience in switching operation to isolate restore required equipment

Direct and train workers to install, maintain, or electrical wiring or equipment

All types of cable laying, termination work

Earth value measuring, various types of lighting erection and testing

Familiarize the types of Hazards in the oil industry and precautions avoid accidents

Construction, Oil safety oriented course completed

Venlub Petro Products Pvt Ltd, Ambattur

Electrical team member, July 2010 – Sep 2013

(Reported to Electrical Supervisor)

Instrument I/O Assignments

Switching authorized person in this company.

Experience in utility and electrical substation maintenance.

Operation & maintenance of 11KV/440V, 800KV transformer.

500KVA, 320KVA, 250KVA diesel generator operation & servicing and connected to mv panel.

Troubleshooting of Electrical System

Test Report Preparation

Operation & maintenance of 11kv/440v, 800kv transformer

Electrical and Pneumatic Actuator Installation and Testing.

Calibration of Pressure, Temperature, Flow and Other Field Instruments.

Inspection of Instrument Installation Works.

Motor Starter like DOL, Star Delta, Soft Starter, VSD etc.,

Natesan Precision Components Pvt Ltd,Chennai

Electrical charge hand, Jan 2009 to Jun 2010

(Reported to Manager and leading team of 5)

Preparation Machines Manuals and Electrical Circuits

Electrical Maintenance of PLC controlled machines using Messung PLC

Planning the Annual Preventive/Predictive Maintenance Plans

Maintenance of lathe, surface grinding, electrical cranes

Handled Plant Expansion projects from Designing level to installation level

Conducting Root Cause (5 why) Analysis & taking corrective and preventive action

Planning and execution of preventive and breakdown maintenance of all types of Equipment on it priority basis

Maintenance of electrical protective equipments like Earth fault/Over current relay

Variable frequency drives programming and able to handled troubleshooted.(LG,SIEMENS,DELTA)

CNC, VMC machines maintenance (Fanuc control)

Maintenance of Milling machine, automatic grinding machine with OMRON PLC, MITSUBISHI PLC

Servo drives, motors able to handle

To work all pneumatic, hydraulic circuits, field instruments

Motor control circuit panel wiring

Troubleshoot in relay logic panel board

Chemtech Process India Limited,Tiruppur

Electrical supervisor Trainee, Jun 2006 to Nov 2008

(Reported to Jr.Engineer & leading team of 9)

Operation & maintenance of 11KV/440V, 800KVA transformer

500KVA, 320KVA, 250KVA diesel generator operation & servicing and connected to mv panel

To work all pneumatic, hydraulic machines

To work various types of motors up to 80 HP motors and their starters

Boiler maintenance able to handled

Panel wiring, VFD troubleshooting handled

Preventive maintenance, breakdown maintenance, predictive maintenance, shut down maintenance handed

Cable laying, termination, glanding, earthing work

Various types of lighting erection

Panel erection,testing and commissioning work machines

Maintenance of Utilities like Compressor/ Generator/ Cooling Towers

Preparation Machines Manuals and Electrical Circuits

Maintenance of Gang saw machines using Omron PLC

Maintenance of surface grinding, lathe, VMC, Drilling, Power hacksaw, electrical hoist

IT SKILLS

AutoCAD

Windows OS

Microsoft Office

Computer Hardware maintenance and assembly

PERSONAL DOSSIER

Date of Birth: 5th Jan 1986

Nationality: Indian

Marital Status: Married

Passport no:P6418289 expired in 29 Dec 2026

Languages: English,Hindi & Tamil

REFERENCES AVAILABLE UPON REQUEST

Recent milestone includes Meeting all the deadlines even under strained situations with ZERO complaint from clients as well as senior management

Scholastics

Diploma in Electrical and Electronics Engineering with 80%,Muruga polytechnic college,Melur-2006

Certificates

-Certificate for Advance Diploma in Industrial Automation and Programming-Chennai

Offshore Training

-Personal Survival Techniques

-Elementary First Aid

-Helicopter Underwater Escape technique

-Fire Prevention and Fire Fighting

Achievements

-Erected 800 Amps MCCB panel for compressors

-Operation,maintenance & erection of 33KV/6.6KV,5000KVA,2500KVA transformer

-Operation & maintenance of 11KV/440V, 800KV transformer

-500KVA, 320KVA, 250KVA diesel generator operation & servicing and connected to mv panel

-Introduced high and under voltage tripping systems for all ACB’s

-Licence with TNEB/CEIG(rule30, rule46, rule63) related work

-Three no. of machine plc converted messung to Omron plc’s

-Improved the power factor operating point from the 0.83 to 0.98

-Three no’s Cummins 500 kva dg installed and rule63 audit done by CEIGf

-Plant down time reduced 2.3% to 0.8%



Contact this candidate