RESUME`
Name; James Robert Forte
DOB; **-**-**45 AGE; 73.4 Years
ADDRESS; 530 Alamitos Ave APT #6
Long Beach, California 90802
TEL; 562-***-****
WORK HISTORY;
From August 20, 1978 to November 30, 2015 I Worked at the Boeing Company (McDonnell Douglas) located at 2401 Wardlow Road, Long Beach, CA 90807 (37 Years). I was “LAID OFF” on November 30, 2015 due to the Boeing C-17 Plant closing.
During this 37 Year time period My main Job Duties were Performing Inspections of all Electrical & Electronic Installations and Systems on the C-17 Aircraft and other Aircraft that were being Built during this time at the Long Beach, Plant.
For a Period of 3 years, 2002 -2005 I Performed TRAINING DUTIES on the C-17 Program for the Computer Systems that were being Implemented to be Used in the Manufacture of the C-17 Aircraft. These Duties required Designing and Printing Training Materials for various Training Classes and, Presenting the Training Classes to the C-17 Employees.
This is an accurate Description of the Work Duties that I have Performed since August 20, 1978.
Boeing Company
3855 N. Lakewood Blvd
Long Beach, CA 90846
TEL. 562-***-****
*** Sample of how I Write Discrepancy’s;
IS: At the Top Area of the Pilot’s “Light Control Panel” on the Left Hand Glareshield.
The Grey Foam Padding (P/N 17P1E1083-501/502) is Riding against the Outboard Side of the HUD UNIT.
S/B: The Foam Padding is not supposed to Ride against the HUD UNIT. Install Foam
Padding Per B/P Requirements.
NOTE: Ref. to Line Check 1661823 which covered Ships F246 thru F250. And, Required that the Foam Padding be Trimmed so that It would not Ride the HUD UNIT.
IS: At the Top Area of the Co-Pilot’s “Light Control Panel” on the Right Hand Glareshield.
The Grey Foam Padding (P/N 17P1E1083-501/502) is Riding against the Outboard Side
of the HUD UNIT.
S/B: The Foam Padding is not supposed to Ride against the HUD UNIT. Install Foam
Padding Per B/P Requirements.
NOTE: Ref. to Line Check 1661823 which covered Ships F246 thru F250. And,
Required that the Foam Padding be Trimmed so that It would not Ride the
HUD UNIT.
IS: Inside Pylon #1 at STA YIN 240.5 INBD at the Connector Disconnect Panel above JE-451. The Overheat Detector Sensor Elements, REFDES 3623RT013 & 3623RT014 do not have "ID Labels" Installed on Structure at Connection Point as Required by
DPS 1.34-12, Paragraphs 4.16.2 - 4.16.2.4 and Figure 5.
S/B: Install "ID Labels" with Correct Nomenclature of [3623RT013-"A" Loop] to Lower Element & [3623RT014-"B" Loop] to Upper Element Per DPS 1.34-12 Requirements.
NOTE: This Discrepancy has been Identified on previous Ships.
REWORK Per B/P and DPS Requirements!
IS: Inside Pylon #2 at STA YIN 240.5 INBD at the Connector Disconnect Panel above JE-351. The Overheat Detector Sensor Elements, REFDES 3623RT037 & 3623RT038 do not have "ID Labels" Installed on Structure at Connection Point as Required by DPS 1.34-12, Paragraphs 4.16.2 - 4.16.2.4 and Figure 5.
S/B: Install "ID Labels" with Correct Nomenclature of [3623RT037-"A" Loop] to Lower Element & [3623RT038-"B" Loop] to Upper Element Per DPS 1.34-12 Requirements.
NOTE: Repetitive Discrepancy, Written on Ships F247 & F249.