Resume:

*** *********** ** **, *******, AB,T*Y *Y*, CELL: +1-403-***-****, HOME: +1-403-***-**** EMAIL: ac41of@r.postjobfree.com

Professional Electrical engineer (PEO & APEGA) with extensive experience in Design, Engineering, and Project management for Oil &Gas, Petroleum refining, Petrochemical, Infrastructure and commercial projects.

SUMMARY OF SKILLS

Extensive experience in basic and detailed design, calculations and design review of electrical systems and documents in Oil & Gas and Refinery EPC/EPCM projects.

Leading the Engineering for 8 nos plant substation design and coordination which includes complete design of E house, 72 kV Gantry, 15 MVA transformer, 72kVcircuit breaker, Bus, switch gear, MCC and vendor coordination etc.

Facilitated electrical power system study and design for high voltage substations.

Orchestrated all phases of design engineering and responsible for design, specifications and contract deliverables.

Resolved complex issues associated with design engineering, system studies, including load flow and stability and the execution.

Detail design of substation control buildings &Substation ground grid design.

Liaised between Engineering Team and Client for design coordination. Represent Engineering Team during Client's review meetings.

Participated in Contract Specifications development and Contractor Bids evaluation. Review vendor/contractor submittals, FATs/FITs reports, Field Marked-up Drawings as Engineer of Record.

Created and developed single line diagrams, Data sheets, Reviewed vendor drawings, Load analysis and Sizing of Transformers, MCC / PCC Panels, Electrical Switchgears, SCADA &HMI and instrumentation.

Experience with Canadian electric code and CSA,NEC standards.

Experience in LV, MV, and HV design and analysis.

Leading a team of designers and engineers for preparation of various technical documents and deliverables.

Experience in load flow, Short circuit, Arc flash studies using ETAP/SKM and relay coordination.

Familiar with software SPEL for producing various deliverables.

Professional Experience

PLY GEM

Period : Present

Electrical Plant Coordinator

Direct and coordinate all on-site electrical activities to comply with specifications, requirements and codes.

Provide direction during functional performance testing of all electrical system.

Implement safety program to meet regulations.

Monitor and audit the performance of personnel assuring that work aligns with specifications, plans, schedules, safety and quality.

Plan, schedule and coordinate all work with Contractors.

Participate in weekly meetings to review and discuss work progress, and area plans to resolve delays .

MACO COMMERCIAL PROJECT

Period: 2015-2017

Electrical Consultant

Prepared the conceptual electrical design including single line diagrams for commercial project.

Performed the preparation of electrical drawings for construction including single line, load list and load summary, equipment sizing, lighting calculation,, wiring diagrams, layouts.

Reviewed engineering designs, made recommendations, and managed required engineering resources and processes as required and coordinated with utility authorities.

Evaluated of electrical construction tenders and recommendation.

Performed all engineering and technical functions in a safe and environmentally responsible manner.

Maintained the business operations excellence by application of engineering principles, practices and technical standards to achieve operational integrity and productivity.

AMEC FOSTER WHEELER

Project: Kearl Oil Sand Project ($ 10 Billion), Alberta, Imperial Oil & Exxon Mobil Project.

Period: 2011-2015

Electrical Engineer

Planned and designed 100 MW load power distribution for Kearl Oil Sand Project includes 8 nos of substation in various locations and client coordination.

Designed 72kV/4.16kV substation which includes 20 MVA, 15MVA, 10MVA and 5MVA transformers, 4 Pole gantry & circuit breaker.

Designed medium voltage & low voltage Switchgear and MCC for Kearl Fine Tailings Treatment.

Developed MV SLD which includes 3000 amps medium voltage switchgear with bus coupler and VFD controlled 4500 HP motors.

Prepared low voltage single line diagram and load analysis for the project.

Produced electrical load list, equipment list based on Mechanical load list and P&ID’s.

Reviewed and commented vendor drawings.

BANTREL (BECHTEL GROUP)

Project: Petro - Canada Refinery expansion Cocker project

Period: 2008 - 2009

Electrical Engineer

Sized transformers and switchgear as per the mechanical load list.

Developed 4.16kv single line diagram and 600 v single line diagrams.

Performed cable sizing calculations, lighting calculations.

Prepared electrical load list, Equipment specifications, and data sheets.

EDUCATIONAL CREDENTIALS

Bachelor’s Degree in Electrical engineering.

Electrical design, Canadian electric code certification.

Certification in PLC and Plant automation.

Project Management.

PMI member.

Power Quality Certified Engineer.