CURRICULUM VITAE ALOK KUMAR SAHOO Mobile: +** -737-***-****
Email: - ****************@*****.***
CARRIER OBJECTIVE:-To work in a professional and growth oriented environment where sincerity is and hard work are appreciated; and to attain professional and personal targets by creating a niche for myself in the industry by acquiring high quality training and enriching in a reputed organization and to prove my skills and abilities in the field of Design / Installation / Commissioning of HVAC.
ACADEMIC PROFILE:-
DIPLOMA in Mechanical engineering with aggregate 70% from Nalanda institute of Technology,SCTEVT ODISHA, Bhubaneswar.
I.T.I. Fitter from with aggregate 88% from Satyasai itc Basudevpur, NCVT,odisa,Bhubaneswar.
Matriculation from BSE ODISSA with aggregate 42% .
EXPERIENCE:-
Work as a mechanical FITTER trainee machanicai depatament krushan mohan enterprises at INDIAN REFINE OIL CORPORATION PARADEEP from 2011-2012 (11 month).
TRAINING PROGRAM:-
COMPANY:- JSP ENGINEERING SOLUTION
COURSE:- HVAC Design and Drafting.
DURATION: - 45 Days
LOCATION: - BHUBANESWAR,ODISHA.
Course Description:-
This is a typical G+5 floor project used for residential purpose. It is located in odisha according to odisha atmospheric conditions the design and drafting of air conditioning system is done for this project; the peak load is taken as the load on May 21st from 8am to 4pm.
It is a typical G+5 project having 4187 Sq.ft. area for each floor and it contains 6 floors. .In the Ground,3 rd,5 th floor AHU OF 80TR,1st floor of VRF,2nd floor of non ductable split ac,4th floor of FCU units are selected.. The chiller piping is also done for the AHU and FCU units.
DESIGN PARAMETERS FOR ABOVE PROJECTS:
HEAT LOAD CALCULATION using E-20 sheets.
DUCT calculation using Duct sizer software .
Diffuser selection.
Static pressure calculation.
Pump head loss calculation.
Chiller selection,Pipe sizing .
CAR PARKING Ventilation.
KITCHEN Ventilation.
BOQ calculation
These parameters are done using AUTOCAD 2014, MCQUAY duct sizer, CARRIER psychometric chart software’s.
This project we have done the following design parameters according to ISHRAE and ASHRAE standards
PROFESSIONAL OVERVIEW:-
Suitable selection of Unitary AC Equipments like all type of Decorative, Ducted Split ac.
Cassette & Packaged AC Units from the respective catalogues.
Suitable selection of Central AC System Equipments like FCU’s, AHU’s, Chillers and
CHW Pumps from respective catalogues.
Preparation of Air Distribution System.
Able to read / understand all sorts of HVAC drawing with foundations / civil / wall
PROJECT & DESIGN MANAGEMENT:-
Responsible for resolving the Site issues by finding the root cause of the problem.
Basic knowledge of real time designing of HVAC systems.
Parameters required for selection of chillier units.
Performing Heat Load Calculations for different projects using E-20 SHEET.
Actively involved in project Installation, execution and commissioning.
TEAM MANAGEMENT:-
Leading, motivating and training the team to improve their operational efficiency.
Guiding the Technicians on basics of Indoor & Outdoor units, and improving quality.
Worked for the Execution of the project which includes selection & Installation of
Machines like FCUs, AHUs, FAHUs and Pumps. And Pipe sizing &Duct sizing (erection
Of chilled water pipes from pumps to different machines and also erection of Ducts
From machines to different zones).
STRENGTH:-
Hard working, sincere, dedicated.
Excellent AutoCAD knowledge.
Willing to work in a group.
HOBBIES:-
Reading Books.
Playing cricket.
Listening music
PERSONAL DETAILS
Name: - Alok kumar sahoo
Date of Birth: - 23-05-1990
Gender: - Male
Marital status: - Single
Nationality: - Indian
Language known:-Hindi, English & Odiya.
I do hereby undertake that all statements made in this application are true, complete and correct to the best of my knowledge and belief.
Date: - 13.09.2017 signeture of candidate
Place: - Bhubaneswar Alok kumar sahoo