CURRUCULUM VITAE
NAME SAYYED SHAH AHSAN MONIS
HVAC Design Engineer,
E-Mail : ac0of8@r.postjobfree.com
Phone : +91-917*******
JOB APPLICATION
To
The HR Manager
Sub: Application for the post of “HVAC Design Engineer”.
Dear Sir,
With reference to the above subject, I avail this opportunity to introduce myself SAYYED SHAH AHSAN MONIS. I am in a field where creative and logical thinking is must and I am confident that I can do justices to the work with my talent and skills.
Being actively involved in the field of HVAC for 6 MONTH, I have gained wide experience, which has benefited me professionally and broadened my creative and logical thinking in the HVAC field.
I am confident to Design & Draft the Mechanical works for commercial, Residential, Hospitalized & industrial projects.
I’m enclosing here my Curriculum Vitae for your kind consideration of my candidature and hope that I may get an opportunity to prove my worthiness.
Keeping in view of my qualification, knowledge and experience, I am confident that I can fulfill the above-mentioned assignment perfectly and live up to your expectations.
Looking forward for a favorable response.
With best regards,
AHSAN MONIS
Enclosure: Resume
BRIEF OVERVIEW:
Looking for a challenging and demanding position in a growth oriented HVAC consulting/contracting/ construction organizations, where there is ample scope for individual and organizational growth.
SUMMARY:
Around 6 MONTH Industry with, good analysis and design capability, good communication and interpersonal skills, proven individually in project management and worked with team of professionals.
POSITION HELD:
HVAC Engineer (Design) in TAIBA CONSULTANT.
WORK EXPERIENCE:
Presently Working as HVAC DESIGN ENGINEER IN TIBA CONSULTANTS, Hyderabad, India
EDUCATIONAL QUALIFICATION:
B.E [MECHANICAL ] with 64.84% from BALAGHAT College (SRTMU,NANDED), AHMEDPUR in FEB -2016.
DIPLOMA(MECHANICAL) with 65.66% [from S.P.M. POLYTECHNIC SOLAPUR IN 2010]
SSC passed with 61% [MERIT] from S S A . URDU HIGH SCHOOL SOLAPUR IN 2005
COMPUTER KNOWLEDGE:
Hvac Design Software:
HAP
ELITE
TOSHIBA
ZAMIL
GENERAL FORM
E-20 FORM
Mc QUAY DUCT SIZER
Mc QUAY PIPE SIZER
CAREER PSYCHOMETRIC CHART ANALYSER
BETA TERMINAL DEVICE SELECTOR
EXPANSION TANK SIZER
CONVERTERS
Drafting Software:
AutoCAD 2000-2015
Operating Systems:
Windows 7, Windows Vista, XP, 98.
Office Package:
MS Office 2010, 2007, 2003 (Word, Excel, PowerPoint)
TECHNICAL EXPERTISE:
HVAC JOB RESPONSIBILITIES:
Heat Load calculations, Heat Loss calculations following ASHRAE Standards.
Air Distribution System by Velocity Reduction Method, Equal Friction Method and Static Regain Method following SMACNA Standards.
ESP Calculations for Fans & Blowers.
Evaporator cooling coil selection.
Toilet & Kitchen Ventilation system Designing.
Stairwell pressurization system Designing.
Car Parking ventilation and fresh air system Designing.
Head Loss calculation for Primary & Secondary Pump system.
Chilled water pumps, condenser water Pumps Selection and power calculation.
Selection of Chillers, AHU S, FCU S, Exhaust Fan, Blower, Window Ac,Cooling Tower, Desert Cooler and other Equipment s.
FIRE FIGHTING JOB RESPONSIBILITIES:
Fire water Demand & Fire water tank Calculation following NFPA Standards.
Head Loss calculation for Fire water pumps system.
Jockey pump, Main Pump, Diesel Operated Pump, and Booster Pumps Selection.
Sprinkler system, Fire Hose Cabinet, Water Hydrant system, Smoke detector, Heat detector Selection.
FM 200(Waterless system) Designing and Fire Extinguisher Selection.
RESPONSIBILITIES AS A HVAC Designer Engineer
Worked as a HVAC Designer Engineer.
Preliminary planning based on Architectural drawings.
Concept/Design discussions with the clients and Architects.
Co-ordination with architectural and structural & all MEP work. Mobilizing manpower and materials at the site.
Checking the weekly and monthly progress, dealing with consultant, reporting the project manager and to the project management team.
Monitoring the sub contractor work progress, checking the quality of work as per specification and approved drawings.
Going for the inspection on the site.
Checking of all HVAC, Service Drawings.
PROJECTS HANDLED:
STANZA Silks is six Flory building with two basements contains a huge area of 1000 square feet. Design of a building and site requirements were handled by our firm
Commercial Centre is a high rise building based in Hyderabad. Designing and Execution were major aspects done by our firm. This project went on for one year and executed successfully
Hill Residency, Hyderabad is a high rise building. A complete HVAC Designing was under taken by our firm
PERSONAL DETAILS:
Name : SAYYED SHAH AHSAN MONIS WASEQUE AHMED
Father s Name : WASEQUE AHMED
D.O.B : 28-09-1988
Marital Status : UNMARRIED
Nationality : Indian
Passport Number :
Language Known : English, Urdu, Hindi.
Permanent Address : 209 shaniwar peth SOLAPUR.413002 MAHARASTRA.
DECLARATION
I hereby declare that the above furnished details are true to the best of my knowledge and belief.
Date :
Place : Hyderabad
Yours Sincerely
AHSAN MONIS SAYYED SHAH