Post Job Free

Resume

Sign in

Engineer Maintenance

Location:
India
Posted:
January 19, 2013

Contact this candidate

Resume:

Telecom Implementation Engineer

Resume keywords summary: Telecom Implementation Engineer for Nokia,Ericsson,Huawei

Please log in to see the contact information!

Work Experience

Experience level: 2-5 years

Profile/Cover Letter: S.MURUGAN

Mobile: +971*********

Email:abp90i@r.postjobfree.com

To serve and add value to your organization that provides an opportunity to gain further exposure, experience and Career Growth by utilizing my potential to the fullest

Summary

Around 5 years of experience in Telecommunication Field. Strong knowledge of GSM & WCDMA concepts. Hands on Experience with Nokia Flexi BTS, Nokia Flexi WBTS, Ultra BTS, Nokia AXC, Nokia Flexi hopper 19 Equipments. Currently working for Hayat Communication as a Telecom Implementation Engineer from May 2009. Proven track record of overachieving assigned targets, excellent relationship management skills and able to work with Team. Skilled communicator with exceptional interpersonal skills and proven organizational abilities.

Experience Summary

Working as Telecom Implementation Engineer for Hayat Communication, Dubai, UAE

Worked as Telecom Implementation Engineer for TCIL, Saudi Arabia

Worked as FLM Engineer for Kelly service India Pvt Ltd, Chennai, India

Worked as BSS Engineer for AIRCEL Ltd, Salem, India

Employment Graph with Noteworthy Milestones

Hayat Communication, Dubai, UAE

Job Title: Telecom Implementation Engineer

Duration: May 2009 Till date

Vendors: Nokia Siemens Networks (DU Project)

Installation, Commissioning and Integration of Nokia Flexi WBTS 2100 MHz

1+1+1 configuration.

Installation, Commissioning and Integration of Nokia Flexi BTS 900, 1800 MHz

2+2+2 to 6+6+6 configuration.

Installation, Commissioning and Integration of Nokia Ultra BTS 900, 1800 MHz

2+2+2 to 6+6+6 configuration.

Installation and Commissioning of Nokia AXC, Flexi hopper 19

Installation and Commissioning of Nokia Flexi EDGE FIFA, Flexi WCDMA FTFA.

Hob upgradation from Flexi hopper 19,FXC RRI to Flexi AXC

Working Experience of Up gradation of Transmission media.(2*2 to 4*2 to 8*2 to 16*2 mbps)

XLM file loading and editing for Nokia Flexi WBTS.

Doing LOS survey for new sites

Perform antenna and feeder test using Anritsu Site Master.

Performs call testing in all time slots, fault isolation and alarm troubleshooting on newly

Integrated and existing Cell Site BTS.

Analyzing & rectifying the Microwave misalignment problems with correct RX LEVEL

Analyzing of BTS VSWR alarms reported at BTS, which includes identifying and replacing of faulty connectors and feeder line.

BTS Expansion, Various configuration and migration of sites from BSC to BSC

Did new site PAT and handover to vandor

migration of sites from BSC to BSC

1. TCIL, Riyadh, Saudi Arabia

Job Title: Telecom Implementation Engineer

Duration: June 2008 to April 2009

Client: Nokia Siemens Networks (STC Project)

Commissioning, Operation & maintenances activities in Nokia Ultra BTS,

Flexi EDGE BTS & Flexi WCDMA BTS (900, 1800, 2100)

Commissioning, Operation & maintenances activities in Flexi transmission unit FIFA, (Flexi EDGE BTS), FTFA (Flexi WCDMA BTS)

Installation and Commissioning of Nokia Flexi hopper, 7GHz,15GHz,23GHz, 38GHz Microwave

Commissioning, Operation & maintenances activities in NEC STM1 & PDH Level 7GHz,15GHz,23GHz, 38GHz Microwave

O&M activity and E1 Provisioning in Nokia Flexi hopper

AT test conducting for Nokia Flexi BTS, Node B, Flexi hopper and RRI Card Microwave

Implemented Chain, Loop & Cascading E1 s in Nokia Hub.

XLM file loading and editing for Nokia Flexi WCDMA BTS

E1 addition to the existing Nokia Flexi WCDMA BTS sites

Doing LOS survey for new sites

BTS Expansion, Various configuration and migration of sites from BSC to BSC

Commissioning and maintenance of Siemens SRA4 Microwave

Link software upgrade in SRA4 Microwave

Link capacity up gradation of SRA4 Microwave

E1 Provisioning for new Node B and 2G sites and E1 END to END test

Co-Ordination with NOC while breakdown maintenance.

Fault analyzing and Trouble shooting

Site planning for implementation of SDH Multiplexer according to the requirement of E1 dropping capacity in BSC & Site locations

Performs call testing in all time slots, fault isolation and alarm troubleshooting on newly integrated and existing Cell Site BTS.

Analyzing & rectifying the Microwave misalignment problems with correct RX LEVEL

Involved in Tower climbing and replacements of ODU during the time of outage

Analyzing of BTS VSWR alarms reported at BTS, which includes identifying and replacing of faulty connectors and feeder line

1. Kelly service, Chennai, India

Job Title: FLM Engineer

Duration: January 2006 May 2008

Client: Nokia Siemens Networks (Vodafone Eassar South Limited) Chennai

Commissioning and Operation & maintenance activities in Nokia Intra and Ultra (indoor, outdoor) BTS

Commissioning and Operation & maintenance activities in Nokia Flexi BTS

Commissioning and Integration of Metro Hubs implemented loop protection.

Operation & maintenance activity and E1 Provisioning in Nokia Flexi hopper,

Installation and Commissioning Nokia Flexi hopper, 7GHz,15GHz,23GHz, Microwave

Commissioning, Operation & maintenance of Ultra transmission unit RRI card (Ultra EDGE BTS),Flexi transmission unit FIFA(Flexi EDGE BTS)

Implemented Chain, Loop & Cascading E1 s in Nokia Hub

Commissioning, Operation & maintenance activities NEC STM1 Level 7GHz,15GHz,23GHz Microwave

Handling and maintenance of NEC NMS

Handling and maintenance of ECI NMS

Commissioning and maintenance of ECI Optical & Electrical STM 1 Level BG20, BG40, eECI Mux

Software up gradation, decommissioning and hop up gradation of Nokia Flexi hopper, RRI Card and FIFA.

Commissioning and maintenance of Siemens SRA4 Microwave

A interface routing from Trans coder to BSC

Nokia Hardware configuration through hardware configuration tool.

Co-Ordination with NOC while breakdown maintenance.

AT test conducting for Nokia BTS and Microwave

Fault analyzing and Trouble shooting

BTS Expansion, Various configuration and migration of sites from BSC to BSC

Performs call testing in all time slots, fault isolation and alarm troubleshooting on newly integrated and existing Cell Site BTS.

Good Knowledge of signaling concepts

Change out of PDH LINK to SDH LINK

Perform antenna and feeder test using Anritsu Site Master.

Analyzing and troubleshooting of BTS External alarms reported at network operation center (NOC), which includes identifying and Rectify the faulty unit.

Analyzing of BTS VSWR alarms reported at BTS, which includes identifying and replacing of faulty connectors and feeder line

2. AIRCEL Ltd, Salem

Job Title: BSS Engineer (Ericsson Equipment)

Duration: May 2004 June 2006

Role: Ericsson O&M (BTS and Transport)

Commissioning of Ericsson BTS s (RBS2202, 2204, 2206, 2111 & 2954) & IBS (2308) using OMT software(s).

Working Experience of Expansion of BTS. (Type with Sync Cable and without sync Cable)

Working Experience of Up gradation of Transmission media.(2*2 to 4*2 to 8*2 to 16*2 mbps)

Installed and Commissioned Microwave Transmission of Minilink (Ericsson) E, Traffic Node (TN-1 & TN-3) as well as High-Capacity (STM-1 M/W links).

Working Experience of High Cap Transmission System (DXX 6320, 6310).

Working Experience of Traffic Node 20p an Ericsson transmission media mapping solution. And worked for traffic shifting from E-Micro to TN

Indoor/Outdoor Repeater Installation and fault rectification.

Capacity enhancement through TRU and BTS addition through expansion.

Monitoring of cell sites through software like Win foil and citric.

Microwave Transmission (Minilink-E) - Link alignments and maintaining Netman connectivity for remote monitoring through NCC, RAC and EAC connections. Using Minilink Service Manager (6.0, 6.3, 6.4 &6.5) software for installing, maintaining and monitoring.

Integration and testing of BTS external alarms on DG panels, PIU (Acme) as well as SMPS s.

Analyzing and troubleshooting of BTS alarms reported at network operation center (NOC), which includes identifying and replacing of faulty magazine

Performed three major Site Migration (Inter BSC and Inter MSC both ).

Cascading of Dual band (GSM1800 & GSM900) BTS.

Loading of Hardware, OAM and Software Scripts to Ericsson

EDGE implementation in various Ericssion BTS

SDH (Microwave) - FRX & FLX 150/600 in STM 1 Level (FUJITSU OPTEL LIMITED - JAPAN)

Working Experience of E1 transmission via Microwave and Fiber media from BSC to BTS s.

E1 Provisioned for new BTS, Inter MSCs in PDH & SDH

RND survey for new sites

Heading the transmission group for Phase IV, V-A, V-B project and planning execution of activities within a stipulated time frame

Fault analysing, Trouble shooting, Quality Checking & Acceptance test for newly commissioned sites in co ordination with Vendor.

Perform antenna and feeder test using Anritsu Site Master

Rectification of hardware and software problems in coordination with Ericsson..

Equipments Handled

Using Garmin nuvi205 model GBS

E1 Tester-Sunset, Acterna type.

Analyser-Agilent (SDH-STM1-16 level)

VSWR-Site Master (ANRITSU and BIRD).

Power and Source Meter.

Drive Testing Kit (TEMS and Agilent)

Software tools

FLEXER Software for operation and maintenance of Fujitsu radio and Multiplexed Equipments (Microwave)

Nokia BTS Manager, Metro Hub Manager, Flexi EDGE BTS Manager, Nokia node B

Flexi Hopper Software for Operation and maintenance of Nokia Microwave systems

MINI-LINK Craft, MINI-LINK TN-HC, Bullet-ProofFTP Software for operation and maintenance of Ericsson Systems

MSM, MNM Software for operation & maintenance of Ericsson systems.

OMT19_2 up to OMT34_9 Software for operation & maintenance of Ericsson systems.

Local Craft Terminal version 6.5- Software for operation & maintenance of siemens system

Map info 5.5, 6.5 Software

Professional Trainings

Training on Nokia Ultra BTS,Flexi BTS and Flexi Hoper

Training on installation and verification of Ericsson RBS3000-UMTS

Training on Mini-link equipments

Training on Ericsson Traffic node

Training on RBS 2202/2206/2204/2104 equipments

Training on Fujitsu SDH equipments.

Training on STM 16(OFC ECI Equipment)

Training on Minilink high capacity

Educational Credentials

Doing Final year BE in Electronics and Communication Engineering, Vinayaka mission University, Salem.

Diploma in Electronics and communication Engineering, Rama Seethe polytechnic

Kariyapatti.

Personal Profile

Father Name : Shanmugaiah.C

Date of Birth : 16tH Marth 1982

Nationality : Indian

Marital Status : Single

Languages : Tamil and English

Address : 65/ Loyal mill colony,

Kovilpatti 628501,

Tuticorin Dist - 628 907.

TamilNadu.india.

Passport Details

Pass port Number : G7222827

Place of issue : Madurai

Year of Issue : 2008

Year of Expiry : 2018

Declaration: I hereby declare that the information furnished above is true to the best of my knowledge.

Place: Saudi Arabia

Date: (Murugan.Shanmugaiah)

No submited work experiences

Background and Experience

No submited educations

Languages

No submited languages

Job Preferences

Job Category: 3g RF Design WCDMA UMTS Job

Job Type: Any Job Type

Job Status: Flexible

Desired Salary: $0 Unspecified

Desired Location: Not Specified

Willing to Relocate: No



Contact this candidate