Yuri McGarry
*** ******* ****** *: 508-***-****
Wrentham, MA 02093 H: 508-***-****
***********@*******.***
PROFILE
R&D Engineering Technician in the medical device field with extensive
experience in a Material Science Laboratory. Provided testing and technical
support for new product transfer while supporting quality of existing
product lines. Ability to recognize, report, and document outliers, trends
and testing errors. Used strong problem solving skills to conduct failure
analyses. Extensive hands-on experience with building and testing
prototypes in engineering protocols. Able to multitask and work
independently as well as perform effectively in a team setting. Proficient
in MS Outlook, Word, Excel and PowerPoint.
TECHNICAL SKILLS
Laboratory Experience Coating formulation and evaluation, medical device
testing, failure analysis; chemical analysis utilizing
Analytical instruments such as, FTIR (Grazing incidence
and Reflectance microscope), SEM-EDX, Optical Surface
Analyzer, Atomic Force Microscope, Contact Angle,
Airborne/ Liquid particle counters, Instron and
Microbalance.
Research and Developed antimicrobial coating formulations to produce
Development Support coated catheters; dip coating processing and high-shear
formulation technology. Supported multiple scientists and
executed various mechanical testing and experiments under
the direction of the Engineering Staff.
Mechanical Skills Superb manual dexterity skill, precise measurements skill
and working under microscope in building complex prototype
assemblies. Conducted various experiments in testing
prototypes. Possess soldering skills of microelectronic
components with J-STD, ESD and clean room experiences.
Performed visual inspection for quality assurance and
conducted dimensional analysis using standard measuring
devices and high-powered microscope.
Method Development Assisted in the development of new test methods for
analysis of nonvolatile residue using FTIR and liquid
particle counting analysis on machined components.
PROFESSIONAL EXPERIENCE
COVIDIEN, Mansfield, MA
2011-2012
Engineering Technician, Dialysis R&D, 06/2011-12/2012
. Developed process for antimicrobial coating formulation to produce
coated catheters
. Maintained and documented experimental test results and observations
within a laboratory notebook under GLP
. Setup, executed and collected data from accelerated aging and
conditioning studies
. Conducted Instron tensile and stiffness testing
SEAGATE TECHNOLOGY, Shrewsbury, MA 2008-2009
Designer and manufacturer of computer hard drives. Formerly Maxtor,
Quantum and Digital Equipment Corporation
Senior Engineering Specialist, Material Science Laboratory, 02/2008-11/2009
. Supported product engineers by collecting data from Electric Torque
Measurement and Leak test using MS Excel
. Performed specimen preparation and analyzed for FTIR and SEM-EDX.
Corrective actions were implemented from the Uni lubed screws
contamination, uncured adhesive from spindle shaft and loose Carbone rods
from polymer components
. Worked with supplier engineer to solve manufacturing issues by providing
technical support as part of a cross-functional team with R&D, Supplier
and Manufacturing Engineering for component optimization
MAXTOR CORPORATION, Shrewsbury, MA 2001-2008
Senior Engineering Technician, Material Science Laboratory, 04/2001-02/2008
. Solved manufacturing issues, conducted tribology testing from the
failed parts by identifying mechanical, process or design issues and
reported to product engineers
. Performed visual inspection on component level and final products to
ensure quality. Identified problematic issues and implemented corrective
actions with Nickel plated Al, SS components and SnPb particles from
soldering residue on main components
. Set up, executed and collected data as qualification from liquid particle
counter to detect micron size particle from machined metal components and
reported deviations using MS Excel
. Assisted with laboratory correlation on lube thickness measurement
QUANTUM CORPORATION, Shrewsbury, MA 1995-2001
Engineering Technician IV, Head/Disk Integration, Heads/Media Group,
11/1995-4/2001
. Identified contamination as Silicon residue from crashed customer
returned drives; assisted in preventing large scale failures and saved
company millions of dollars
. Assisted with Worldwide laboratory correlation by performing analysis of
microgram-level nonvolatile residues (NVR) on drive components using FTIR
and generated calibration curves using MS Excel
. Maintained and oversaw calibration of lab equipment to meet ISO 9000
requirements
. Performed wear, corrosion resistance testing and surface analysis for
component level optimization
DIGITAL EQUIPMENT CORPORATION, Shrewsbury, MA 1984-1995
Engineering Mechanical Technician IV, Advanced Development HGA Engineering,
10/1984-11/1995
. Assisted in transferring new products, assemblies and
processes to manufacturing
. Hand-assembled first prototype Head/Gimbal Assemblies under microscope
and tested delicate prototype piece-parts for early engineering
evaluation
. Trained production line technicians and personnel on soldering procedures
and building HGA for early stage production OEM heads
. Conducted engineering experiments to investigate the mechanical behavior
of HGA for mechanical resonance characteristics and assisted solving the
resonance issues
EDUCATION
Engineering Certificate, Central New England College, Westborough, MA
Additional workshop for Introduction to Six-Sigma