Sam Moosavi, P.E.

*** ****** **** *****

Argyle, Texas 76226

**********@***.***

214-***-****

Objective Provide engineering services and develops my electrical

engineering skills, advancing my career in electrical design, project

engineering, and project management.

Summary I am a Graduate Electrical Engineer with fifteen years

experience in engineering low, medium, and high voltage power systems,

and construction management. I have managed projects in the substation,

industrial/environmental, commercial, and telecommunications industries.

Industrial experience includes the design and development of

one line diagrams, three line diagrams, schematics, wiring diagrams,

relay selection, and modification of physical layout for 230kV to 500kV

substations. Designing municipality water and wastewater power systems

consisting of pump stations, chemical buildings, thickening buildings,

sludge dewatering buildings, blower buildings, control buildings,

electrical buildings, administration buildings, clarifiers, vaults from

15KV to 480V service, communication, and duct bank routing for entire

plants.

Commercial experience includes

project management and complete designs for medium and low voltage power

distribution for a variety of high and low-rise office buildings, hotels,

mixed use facilities, hospital, medical building, retirement home,

assisted living, data center, schools, university, department stores,

churches, Shopping center and infrastructures.

Problem solving and providing

innovative ideas are my major strengths, as I am a quick learner and

adapt well to different environments. I am process oriented, pro-active,

and enjoy working in a team environment while operating with detail and

system level perspectives.

Professional

Licenses Texas: #91910

Oklahoma: #21370

Nebraska: # E-13209

Experience System Associated Inc, TX (JUN 1 2009

to Present)

800 WEST AIRPORT

FREEWAY,SUITE#611

IRVING TEXAS 75062

Project Manager& Project Engineer:

The following are examples of tasks

performed in projects:

. I did design Electrical power distribution including all aspects of

commercial facilities.

. Project management for various projects including coordination

between MEP disciplines, clients and contractors.

. I did design circuitry, calculating loads, voltage drops and short

circuit calculations. Sizing wires, breakers and motors for

electrical and mechanical equipment and lighting design.

. I did Coordinating applications of electrical equipment and

materials with manufacturers and representatives.

. Producing study reports and cost estimates for clients.

. Responding to RFI's and reviewing submittals.

. I have Knowledge and understanding of NEC, IECC and NFPA codes.

. Conducting site surveys, attending meetings and completing punch

lists

. Complete medium and low voltage power distribution system design

for commercial facilities including high rises, upscale resorts,

hotels, and condos, universities, call centers, and concert halls.

. Project management for various projects including coordination

between MEP disciplines, clients and billing.

. I did Coordinating applications of electrical equipment and

materials with manufacturers and representatives.

. I did energy code reports using COM check.

. Traveling for surveys, meetings and punch lists.

. Producing complete electrical specifications for projects

Dashiell LLC. Bedford, TX

(April 25- 2008 - Feb-28- 2009)

Electrical Engineer& Project

Engineer

2350 airport FRWAY,

Bedford Texas, 76022

The following are

examples of tasks performed:

(Contract by MRI. Inc. to

full time position)

The following are examples of tasks performed:

. Design and develop the concept ional design for fire alarm and

security system.

. Develop relay Panel layout per PECO standard.

. Design and develop the L&P one line Diagram. Performed Load

calculation for AC/DC Panels, Panel KAIC rating and Panels

arrangement in control room.

. Utilizing vender equipments drawing for DC schematic connection such

as 230KV breaker, current transformer ratio, circuit breaker alarm

contact,aux contact switch "a" & "b", trip coil1,and trip coil2.

. Developed Dc schematic on 230 KV substation utilized SEL311L, SEL

421, and SEL 352 Relay.

. DC schematic on 230kv base on approved single and three lines

diagram Utilizing SEL 421, as primary relay, SEL 311C as

backup relay, SEL 352 for breaker failure, and SEL387Z for bus

protection.

. Removed wave Traps on Phase A, Phase B, and wave traps, existing

carrier control primary and backup transfer relay panels. Develop Dc

schematic SEL311l, SEL 421, and SEL 352 breaker failure for

replacing existing system.

. Utilizing vender equipments drawing for DC schematic connection such

as 230KV breaker current, CT,CCVT, and MOD.

. Equipment Wiring connection from Yard electrical devices to

Marshalling Cabinet.

. RTU layout and develop the SCADA analog, status and control points,

SCADA system schematics and input point data utilizing the HarrisD20

with communication interconnection with SEL

2020.

. Provide the communication control topology between the

communications SEL2020, and protective relays.

Gupta & Associates, Inc. Dallas, TX (May, 05 - April-2008)

Electrical Engineer&

Project Engineer

13626 Gama Road

Dallas Texas 75244

(Contract by Gupta &

Assoc. Inc. Self-Employee)

The following are examples of tasks performed in wastewater project:

. Responsible to design plant Medium to low voltage substation from

13.8kv to 480v system.

. Design electrical power distribution for Pump stations, Lift

stations with backup power.

. Responsible for preparing electrical distribution system from

12.47kv to 2400v, 12.47kv to 4160v, 12.47kv to 480v through

distribution pad mounted transformer to feed MV & LV MCC.

. Responsible for preparing single lines for MV & LV switchgear,

backup generators, to feed entire pump station and partial plant

service entrance, coordination with utility company transformer,

and calculate and sizing plant internal transformers, and MV & LV

Motor control center(MCC).

. Developed design Narrative, cost estimates, construction

inspections and performance tests during final stage of projects.

. I was Responsible to preparing electrical distribution system

from480/277v to 208/120v through distribution dry type transformer.

. Performing short circuit analysis, motor starting studies,

Protection relay setting calculations & coordination curves using

SKM software.

. Preparing electrical equipment specifications and reviewing vendor

shop drawings.

. Preparing equipments layouts, schematics & wiring drawings.

. Design Multilin 469 motor protection and Multilin 750 for feeder

protection.

. Review and design area classification drawings such as: grounding

design, lighting design, fire alarm, security system, Electrical/

PLC interface diagram, cable tray, power layouts/plans & heat

tracing design review and support field construction.

. Preparing project cost estimation, and bid analysis during bid

period.

. I have Knowledge of industry codes and standards (IEC, NFPA, ANSI,

IEEE, NEMA).

. Design and development of electrical systems for the waste water

and raw water projects listed below:

. Project engineer and project management

. Performed load flow study using power world simulator ver.8.0. up

to

Maximum total 37 buses study.

Reed, Wells, & Benson, Inc. Dallas, TX (Nov.,2004 - March, 2005)

(Contract by Reed, Wells, & Benson, Inc. Self Employee)

. Performed Power Systems Studies with Power System Analysis

software using SKM (DAPPER/CAPTOR) program on critical power

generator/ups paths for Telecom Company in Dallas.

. Performed short circuit calculations and time-current

coordination among breaker devices in order to achieve

maximum circuit protection consistent with electrical service

and recommended protective device settings.

. Perform all electrical engineering functions data, and power

system modeling, short circuit current studies, protective

device coordination studies.

Tectonic Engineers, Co., Dallas, TX (June, 2002 - August, 2004)

Project Manager/Electrical

Engineer

. Planned and designed engineering projects with complex

features.

. I did Laid-out drafting work, and Perform engineering studies

and computations.

. Preparing reports and making presentations to management, and

supervising installation and construction.

. Equipment selection and electrical design development on

various types of equipments including transformers, medium

and low voltage switchgear, protective relays, generators,

power cabling, main tie main, and grounding systems.

. I was in charge of Multi-million dollar Dallas Independent

School District projects.

. I did design electrical power distribution for High-rise and

low-rise Marriott Hotel projects.

. I did electrical power modification distribution to

Wastewater projects.

Turner Engineers, Inc., Dallas, TX (FEB. 2000 - May, 2002),(July,1996 -

Feb.1999)

Project Manager/Electrical

Engineer

. Responsible for the analysis and design of Electrical systems

while coordinating with host architectural firms, builders

and city planners, during design and construction.

. I did Performed electrical load analysis, load assessment,

equipment selection, system design, and preparation of

electrical specifications.

. I was Responsible for managing projects from initial design

through construction.

. Visit the construction site every two weeks to check the

progress of project.

. Responsible for providing construction assessment fee base on

site visit for the owner every month.

. I design Multi-million dollar hospital renovation and design

utilizing medium voltage for service entrance and substation

to feed the hospital.

. Call center, Plano school district, Fire station, police

center, shopping mall.

. Movie Theaters, Department Stores, HEB grocery including

central market.

. Renovation and modification of University of Texas at

Arlington.

. Data center, Telecommunication room and clean room.

C.C.R.D Partner Engineers, Inc., Dallas, TX (Sept., 99 - Jan., 00)

Electrical

Design Engineer

. Developed the Electrical Single Line Diagrams; performed

Short Circuit, power quality, Power System studies to ensure

appropriate equipment ratings and power system performance.

. Multi-Million hospital Renovation design voltage for service

entrance and substation to feed the hospital

. Performed breaker Coordination Studies and breaker setting,

developed motor control and generator back up system.

. Worked with the Project Team to develop the electrical

documentation details drawings and working with Electrical

Equipment Suppliers and internal procurement organization to

develop major electrical equipment order specifications.

. Designed main tie main Electrical systems with generator back

up power for critical power and life safety for hospital.

Carter & Burgess, Inc., Fort Worth, TX (March 99 - Aug., 99)

Electrical Design Engineer

. Responsible for designing medium 13.2kv S&C switch gear in

distribution plant.

. I did Worked with multiple engineers and CADD disciplines to

ensure quality control.

. I have Perform field surveys to verify as-built conditions

and code compliance.

. I have Perform short circuit and device coordination studies.

. Designed and develop the lighting design and control

schematic.

Education MSEE and BSEE in Electrical Engineering from

University of Texas at Arlington

BSAE in Aeronautical Engineering from University of St.

Louis at St. Louis, Missouri.

Airframe and Power plant Licensed by Federal Aviation

Administration.

Technical Skills AutoCAD 2000, Micro station, Load Flow, Microsoft

Excel, Microsoft Word, Math CAD, SKM "POWER SYSTEM COORDINATION", and

familiar with ETAPS.

References -Todd Oliphant Senior Engineer

Associate (UL) 469-***-****

- Don Penick

Application Engineer Eaton Group 817-***-****

- Rodney Welch P.E.

Elec. Principle at Aguirre Roden 972-***-****

-Robert Williams P.E.

Chief Elect at NTWM. 972-***-****

-Kasi Tallapaneni P.E

Chief I&C at Gupta 817-***-****

-Brian Eisenrich P.E.

Project manager at Parsons 817-***-****

Work status US CITIZEN