Wesley C Bell
Kirtland, OH 44094
H: 440-***-****
*******@*********.***
C: 440-***-****
Summary
Highly capable Senior Process Controls Professional. Significant
experience in delivery and support of process automation systems. Led
dozens of successful power plant DCS system installations and start ups
with aggressive schedules and challenging milestones.
Assured correct installation, commissioning, configuration, and those
systems meet all specifications. Known as a proficient troubleshooter,
able to work with multiple project participants to resolve any problem
quickly, resulting in projects that are on time, within budget and to the
customer's satisfaction.
TECHNICAL SKILLS
Operating systems, Windows NT, XP, Server 2000 -2007, VMS,
application QNX, Office suite, Fox Pro, Dbase 3
software:
ABB/Bailey Console OIU, OIS20 & 25,MCS, Lan90, 800xa
Platforms: Process portal A, PPB, Virtual PC,
Conductor NT & VMS, Lan90
System Security, Networks, Back-up and
Maintenance: Recovery, Tuning
Communications OPC, Modbus, Profibus, Foundation field
bus, Hart
Tools: Electronic meters, Scopes and Analyzers
Professional Experience
Trade Wind Services LLC Richland, WA
Subcontractor to Washington River Protection Solutions
Contractor to USA Department Energy
I & C Engineer 2010 - Present
Design, Integrate, Build and Install ABB 800xA DCS system. Program and
Configure system applications, Networks and control algorithms. Authored
engineering documents detailing the replacement of multiple PLC based
systems into an integrated DCS. Revised P&ID, Loop, Elementary and wiring
drawings. Coordinated installation, energizing and commissioning. Review
and supported Factory, Construction, Functional and Operational acceptance
tests. Participated in equipment start up and turnover, control loop tuning
and problem resolution.
. Team member on a USA Recovery Act project for the Department of Energy at
the Hanford nuclear site. Project replaced multiple PLC based systems
scattered across the 60 square mile site with state of the art ABB 800xA
Distributed Control System and a upgraded redundant support network. In
an environment that stifled the timely completion of tasks the
installation and construction acceptance tests were completed on
schedule.
ABB INC. Wickliffe, OH
Senior Field Service Engineer 2000 -2009
Installed and energized systems. Led and coordinated commissioning
activities. Ran functional and acceptance tests. Oversaw plant start ups,
provided control loop tuning and problem resolution. Trained plant
operators, instrument techs and junior engineers, provided emergency field
and phone support for ABB 800xA and Bailey vintage DCS control systems.
Sold and implemented upgrades.
. Led field start up of latest 800xA control system using newest
technologies Foundation Field Bus, Any bus and 4 OPC interfaces at
Detroit Energy's Monroe MI. FGD project. Single point of site contact for
ABB project management, URS Washington Group architectural engineers,
Electricians and Detroit Energy. Coordinated visiting engineers and
vendors assuring problems were resolved to customer satisfaction. On time
start-up resulted in a go for future projects. 2009
. Assembled, configured, installed, tuned and tested 800xA high
fidelity simulator for DTE Monroe using GSE model. Built system in
Wickliffe, interfaced system to GSE high fidelity model in Baltimore,
installed and trained customer in Monroe MI. Successful completion
enabled DTE to train there operators so project continued on time 2008
* Delivered Harmony Process Portal B DCS and a Harmony based training
simulator using TREX high fidelity model to OPPD in Omaha NE. As Team
leader successfully replaced Boiler, Turbine, ILS, BOP systems with VMS
consoles, Composer work stations and Bailey vintage controllers in a 6
week plant outage resulting in incentive payments. 2006
. Configured and implemented ABB's first Industrial IT 800xA based high
fidelity simulator using ESCOR model. System integrated and tuned at
ESCOR plant in Carlsbad, CA and installed on time at Colstrip, MT
training facility. Customer satisfaction resulted in order of second
simulator and kept PPL Montana project on schedule. 2003
* Developed and delivered ABB's first Industrial IT 800xA control system
targeting the Power Utility market using Bailey standards. As project
team member integrated, engineered, implemented control schemes and
tested system in ABB Wickliffe. Installed and commissioned at PPL Montana
Colstrip Unit 4 power plant in 2003. Success resulted in the go ahead for
remaining 3 units in 2005 and 2007 and upgrades and contracts for
continuing support as well as many future orders from other utility
companies;
BAiley controls Denver, CO 1978 - 1999
Field Service Engineer
As team leader or member participated in every aspect of delivering Bailey
DCS control systems, from sales proposals to installation and continued
field support.
. 20 years experience installing and supporting Bailey Controls DCS
systems 955, 1055, DMUX, Network 90, infi 90, Harmony. Worked at over 30
power plants, 6 petrochemical pants, 4 major waste water projects.4 pulp
and paper mills and Coors brewery. International work performed in New
Zealand, Jordan, Saudi Arabia, Mexico and Canada.
BAiley Meter Wickliffe, OH 1976-1978 1
Computer Technician
* Worked on development of Bailey 1055/1090 computer based control
system and Net 90 microprocessor based controllers. Followed first
1055 systems to the field and assisted in successful start ups
resulting with over 20 computer systems orders and 1000's of
Network90, Infi90, Harmony systems orders. Promoted to field service
Engineer.
Education
Control Data Institute Cleveland, Ohio
Certificate, Computer and peripherals repair, maintenance,
Ohio Institute of technology, Columbus Ohio
Electronic engineering technology, 50% of program completed,
Classes completed Formal ABB University Training
Y153 - Service Site Leader Training
M301 - Power & Grounding for Distributed Control Systems
E143 - System 800xA - Troubleshooting Core System
E123 - System 800xA - Engineering Methodology with Function Designer
E160 - System 800xA - Planning, Implementing & Testing Security Concepts
E144 - System 800xA - Performing a System Health Check
T321 - System 800xA for Harmony: T530 - Control Builder Professional,
Configuration
T305 - System 800xA Administration: T302 - 800xA Maintenance and
Troubleshooting (SV4)
T306 - Configuring System 800xA Information Manager: M211- S800 I/O for
Harmony Control
T685 - Process Portal A with AC800 Integration, Configuration and
Operation
M201 - DCS Harmony Control Unit: M207 - Maestro NT Configuration
T619 - PPB B0 Database Maintenance and Upgrades: M306 - Open VMS
T617 - Foundations of Operate IT B0: US944 Composer with EDE Tools
Conductor NT
US905 - Microsoft Windows Technologies for Industrial IT: M300 - Local Area
Networking
US904- Advanced Windows 2000 Technologies Course