Nuclear/Structural/Industrial Inspector

Patrick J. McMahon

***** *. ****** ***, *****, OR 97013 503-***-**** hm, 971-***-**** cell

zp9ri7@r.postjobfree.com

CWI/ICC Special Inspector/NDT LII/QL level 1 Nuclear,Structural Steel fabrication &field erection

& Industrial projects

Structural steel and industrial construction / fabrication AWS CWI, ICC Special Inspector S1/S2AWS, and NDT level II RT, UT, MT,

PT & VT with 20 years experience inspecting shop fabrications, field projects and outages, pipelines, pressure vessels, large

microchip multi structure erection projects to residential additions, industrial projects and outages at pulp and paper, petro chem,

refineries, nuclear work onsite as well as fabrication offsite, hydroelectric Army corp. of Engineer projects on Columbia river dams,

FAA, and Mil standard applications.

Key Skills

Construction/Industrial Projects Welder Quals/WPSs/QA Services

Level II RT,UT,MT,PT,VT NDT Tech Periodic/Continuous Inspection

CWI Welding Inspection Plans Review/Compliance Inspection

QA/QC/Field & Fab Shop Jobs ICC S1 and S2AWS

Employer Summary

AMEC QA CWI/UT MT LII NY/NJ Port Authority Insp Twin Tower’s Rebuild, Sommerset NJ 06/12 to 9/12

Performed QA visual, UT and MT inspection of material previously accepted by on site QC staff on structural steel to AWS D1.1,

and AWS D1.5 codes. Performed welding observations during fabrication verifying compliance with approved WPS’s, verified pre

heat prior to commencing work on items requiring such, verified origin of materials being used and consumables used during

fabrication, performed pre coating prep visual inspections of parts to receive surface prep and or coatings, then final visual

following blasting, and or coating application and finally placing the Port Authority stamp on each piece/sub assembly and

generating and completing the shipping documents sent out with each item or piece. Reported directly to the NY/NJ Port Authority

any NCR issues, daily reports and final shipping documents for their review. AMEC Level III, supervisor Bruce Berger (858) 336

3501

AMEC QA CWI/UT MT LII Texas Cross Trans Line, Tulsa OK, Dallas Ft. Worth Huntington TX,

02/12 to 06/12. Performed QA UT shearwave inspections of 100% of the welds inspected by the various

QC personnel at the 4 locations. Inspected metal power pole CJP welds identified to contain known defects from the fabrication

company that welded these connections initially. Identified numerous layers of defects in each of the approximately 500 pieces

examined, plotted and marked these defects for repair, then verified each defect had been removed and re welded to meet the

inspection criteria. Worked closely with QC and production welding supervisors and welders to try to minimize multiple repairs on

any one piece. Performed UT inspections constantly during the 10 hour days identifying literally thousands of class A, B and C

defects. Documentation and reporting so many indications per piece along with at times multiple repairs prior to acceptance was

very difficult and constant verification inspections were performed. AMEC LIII,supervisor Bruce Berger 858-***-****

B&W QC inspector for the R20 Condenser install Richland WA at Energy NW 3/11 to 9/11

Performed CWI, MT and PT inspections for condenser replacement. Work plan review, welding observations, receipt inspections,

materials evaluations, and welding engineering experience. Project currently complete as of 09/2011. B&W supervisor Phillip

Baker 562-***-****

QL Level I QC inspector for new CRDB Bld

NC Sturgeon (QISI) Urenco Hobbs NM 10/10 to 3/11

Performed CWI and ICC High Strength bolting and receipt inspections as required to complete the project. Work plan review,

procedure compliance observations, procedure and document review as required to support the craft. Performed process piping

inspections as requested by LES engineering in the 1001 copper and stainless Nitrogen system installation. Both projects

completed, signed off and reviewed/verified prior to my departure. NC Sturgeon supervisor Chris Quinn 440-***-****

ACS, Inc. (Tigard, OR) Construction Special Inspector/Building Official/NDT Tech, 4/10 to 10/10

Retained to provide Special Inspection/Building Official services, and Level II NDT duties for structural projects, ODOT,

Caltrans and various municipality projects using AWS D1.1, D1.3, D1.4, D1.5, D1.6 standards among others to provide

third party verification inspections of welding, high strength bolting, proprietary anchors, SFRM (fireproofing) and related

as required per project. Performed UT to FEMA 353, AWS D1.1 and D1.5 for both structural and Bridge structural steel

both on site and in fabrication shops. Plate, pipe, shapes and wideflange connections inspected, both with and without

backing. ACS supervisor Mark Powell 503-***-****

Hogan Fab, Inc.(Portland,OR) QA/QC,Receiving, Welding Sup/NDT Tech and CWI, 2009 2010

Provided QA/QC, CWI, NDT, document control, plans and wps adherence supervision duties for a D1.5 shop providing mainly sign

bridge and AISC type structural steel for the DOT’s for many states, often working under the direct scrutiny of Level III inspectors

for those agencies. Many hundreds of CPJ welds were inspected using D1.5, as like anyone using that code there were also

numerous repairs to be re worked and re inspected. Was able to provide the QA inspectors clean defect free work consistently.

Document control for QA manual revisions/audit’s, MTR’s, plan and acceptance criteria compliance and documentation, C.O.C’s

and MTR certification portfolios for various projects running simultaneously. LIII Caltrans Mark Wright 818-***-****

Carlson Testing, Inc. (Tigard, OR) Construction Special Inspector/Building Official/NDT Tech, 1997 2009

Provided both shop and field erection special inspections, required NDT inspections and third party plan verification inspections of

structural steel as an AWS CWI, ICC SS & Welding Special Inspector, WABO Building Official, OBOA Building Official, and City of

Portland SS Special Inspector. Took and passed the FEMA T operators exam twice and passed both times. Performed the

majority of the SMRF and FEME 353 CPJ special connections for most of the time at Carlson. Performed mainly shop and field

erection UT inspection of both AWS D1.1, D1.5 and FEMA 353 connections. 1o’s of thousands of CPJ welds inspected, all types of

connections, sizes and materials. Completed or participated in shop and field erections of projects from “Street of Dreams”

residential projects to the Jimi Hendrix Experience Music exhibit 2 yr shop inspection project, to a three year shop and field

erection of Safeco field in Seattle and 100’s of similar projects . Carlson LIII Mark Powlison 800-***-****

Ind. NDT LII,

INDT(Mobile,AL Augusta, GA Jacksonville, FL Richmond, VA Iron Mt, MI Savannah, GA) 1993 97

Performed NDT inspections as a level II Radiographer, UT Shearwave, Magnetic Particle, Liquid Penetrant, and Mechanical Level

visual inspector at industrial settings like Nuclear power plants, Pulp & Paper, refineries, petroleum and chemical plants, pipelines,

pressure vessels, storage vessels and related process piping, aero space, hydro electric and other power producing facilities both

on and off shore all over North America. Many standards including ASME, ANSI, Mil Standards, API 510, 653 and 570, API 1104

and many others dealing with too many different materials and shapes to list. Was a member of the team that initiated the API 570

program in Kingsport TN at Tennessee Eastman chemical plant. Extensive UT baseline as well as in process evaluations were

initiated using UT. Many various types of materials are used requiring an extensive box of calibration equipment. We did thickness,

erosion/corrosion, and component fatigue evaluations starting a whole new way of inspection at the facility. Was a part of the team

who developed the thinwall tube inspection by shearwave of new boiler tube welds. Our team, along with oversight RT teams

developed and repeatedly were able to verify results of a new procedure stil being used today. GE supervisor Doug Bland (423)

279 9627

Industrial NDT Technician

Longview Inspection, Inc (Clackamas, OR), 1990 1993

Performed much the same type of NDT inspections at the same type of industrial settings across the US as a Level II Ultrasound,

Radiographer, Magnetic Particle and Liquid Penetrant inspector. Extensive travel and 12 hr shifts 7 days a week until

outage/project completion 300 days a year. Thousands of hours doing UT thickness surveys in 100’s of plants. Hundreds of hours

doing B Scan UY of reactors and other heavily insulated items, hundreds of hours verifying material thickness at steel production

plants, IGSCC inspection of steam piping for power plants sizing known defects as part of a corrosion analisis project for a multi

facility plant. UT inspections of flood locks at Army Corp of Engineers hydro electric facilities located on the Columbia River.

Accuren supervisor Mick Halverson 503-***-****

Nat’l & International Certifications

AWS CWI QC 1 (1997 Present) #97110411

Valid through 11/2012

ICC SS & Bolting(S1)/SS & Welding(S2AWS) Special Inspector (1997 Present) #1073617

Valid through 7,8/2013

NDT Level II’s as Radiographer, Ultrasound (FEMA), Magnetic Particle, and Liquid Penetrant (1991 present)

Valid through 6/2012 (would test upon acquisition of services)

Documented classroom training hours in excess of twice the required amount (per ASNT TC 1A req’s) of hours for

all disciplines and documented “On the job training hours” as required are available upon request.

Education

Glide High School (Glide, OR) Graduate Class of 1987

Oregon Tech (Klamath Falls, OR) 1988 89 Associates in Manufacturing Engineering

Certified Boom lift/Scissor lift operator, Confined Space Entry, First Aid/CPR

Personal References Available upon request

Professional References –Available, but only to secure employment

.

=



Contact this candidate