CURRICULUM VITAE
K.SURYANARAYANA
Devanga Street,
RAMAVARAM-533264,
E.G.Dt., ANDHRA PRADESH Phone: 089********
. Email : **********@*****.**.**
Job Objective
To endeavor for a challenging career where in my commitment to work and passion for learning are oriented towards the achievement of the organization goal.
Executive Summary
About 10 Years of experience in Power & Water Treatment Field
A strategic planner with expertise in Project works and managing commissioning & operation of utilities equipment like DM & R.O Plants,Pre-Treatment Plant and ETP etc.
An effective communicator with excellent relationship management skills and strong analytical, leadership, decision making, problem solving & organizational abilities.
Academic Credentials
S. No S.No. Qualification Board/University Year of Passing Percentage (%)
1 M.Sc., Chemistry Periyar University
Salem, Tamilnadu 2010 71.4 %
2 B.Sc., (M.P.C) Andhra University
Visakhapatnam, A.P 2001 69.9 %
3 P.G.D.C.A CRC Computer Education
Anaparthi, A.P 1999 Grade-A
IT Exposure
Familiar with MS office (Word, Excel, and Power Point),
Familiar with SAP-QM.
Experience summary
M/s Konaseema Gas Power Limited, Devarapalli since January 2009 to till date.
M/s Nava Bharat Ventures Limited, Samalkot and Dharmavaram since December 2005 to January 2009.
M/s HIQ Power Associates Pvt Limited,Chennai since February 2003 to December 2005.
M/s Vamshi Industries Limited, Dwarapudi since October 2001 to February 2003.
Present Experience
From January 2009 to Till date:
Working as a Chemist in M/s. Konaseema Gas Power Limited, Devarapalli (445MW Combined Cycle Power Plant) having 2X140 MW Gas Turbines (Make: Siemens AG, Germany) and 1x165 MW Steam Turbine (Make: LMZ, Russia).
Key Responsibilities:
Responsible for the overall Operations of Water Management Systems, Laboratory Analysis, Procurement of Chemicals & Instruments, Man Power Management and also looking after total Environmental aspects of the Power plant.
Experience in Detail:
• Setting-up and commissioning of Chemical Laboratory.
• Analytical method development, validation and writing SOP's.
• Lead the chemistry department with the help of HOD, developing the technical skills among the team regarding operations of equipment & monitoring the parameters & taken responsibility for all the activities.
• Operation & Working on PLC System (GE Fanuc) in D.M Plant. (Capacity 2 x 29 M3/hr, Doshion Make, Stream PSF, ACF, WAC, SAC, DG, SBA and MB). Monitoring the DM Plant Water Analysis & Optimizing the Plant Operation as per the Analysis Results. Prime responsibility involves DM Plant operations to achieve zero breakdown targets planning and effective utilization of resources.
• Operation of Chlorination Plant (Capacity: 160 Kg/hr., Make: Pennwalt Ltd, Mumbai), Maintained the Chlorine Leak Absorption System & Leak Detecting System in good condition.
• Monitoring & Control the CW Treatment for 50,000 M3/hr. circulating capacity counter flow induced draft cooling tower, Pre-cleaning and Passivation & Analysis of Corrosion Coupons.
• Monitoring & Control the Boiler Water Treatment for 2 x 278 TPH HRSG (L&T make with three pressure stages, HP-221 TPH, IP-38 TPH, LP-19 TPH), experienced in Alkali Boil Out & Acid Cleaning of Boiler.
• Commissioning & Operation of Effluent Treatment Plant.
• Monitoring the Hydrogen Purity inside the Generator Casing.
• Monitoring & Control the parameters of Stator Cooling Water System (including Ion exchange filters and Nitrogen capping) and Closed Cooling Water System.
• Taken lead to solve the Sulphuric acid dosing, storage and unloading system problems.
• Lead the Side Stream Filtration Units (VAG Filters) Commissioning, 4x125 M3/hr. capacities.
• Preparation of monthly performance reports, technical reports like monthly bulk chemicals reports etc., and submission of the same.
• Monitoring of Environmental aspects of the plant, like ambient air, water and Exhaust stack Emission measurement and submitting the monthly reports to the statutory bodies..
• Maintained good preservation for HRSG & DM Plant before Plant commissioning.
• An active member of Combined Cycle COD test team & taken responsibility for Effluent and Environmental Systems during test period.
• Calibration of the various laboratory instruments like pH, conductivity, turbidity, flame photometer etc.
• Hands on experience in operating of UV Spectrophotometer, Flame Photo meter, KF Coulometer, Millipore Synergy Water System, Flash Point meter, ORSAT Apparatus, Online Silica Analyzer etc.,
• Hands on experience in analysis of Water, Steam, Bulk Chemicals, and Preparation of all kinds of laboratory reagents (normality solutions etc.,)
• Introduced Method of Least Squares for Spectroscopic analysis for getting more accurate results.
• Given Training to the Trainee Chemists for testing of Hydrogen Gas Analysis & Flue Gas Analysis by ORSAT apparatus.
• Analysis of oil like, Lubricating oils, transformer oil and hydraulic oils analysis.
• Attended Training for Chlorine & Other Hazardous Chemicals Handling & Safety at M/s. Andhra Sugars Limited, Kovvur.
Previous Experience
From December 2005 to January 2009:
Worked as a Junior Officer M/s Nava Bharat Ventures Ltd (Thermal Power Plant 20MW and 9MW) at Dharmavaram and Samalkot.
Experience in Detail:
• Experienced in Erection and commission of 9MW and 20MW water treatment Related works.
• Analyze of Boiler water.
• Control & Monitoring of all the preservation activities related to DM Plant & HRSG
• Monitoring the CW chemical treatment.
• Erection and Commissioning of 30M3/hr and 15M3/hr capacity DM Plant (Supplied by Ion Exchange Ltd).
• Experienced in Raw water Clarifier Treatment (Clarifier Capacity 500M3/hr).
• Steam water cycle samples analysis and control.
• Experienced in De-Mineralization plant resin Brine treatment.
• Pre Treatment of Raw water.
• Analyze of Raw Material and Safe Handling.
• Analyze of Coal & Beggase (Moisture, GCV, Ash Percentage).
• To look after statutory requirements like Pollution levels etc.
• Preparation of Environmental Monitoring Report.
• Prepare ISO Related Documents.
• Prepare 5S Related Documents
From February 2003 to December 2005:
Worked as a Chemist in M/s HIQ Power Associates Pvt Ltd,Chennai (O&M Division)
Experience in Detail:
• Erection and Commissioning of Capacity 12M3/hr DM Plant (Supplied by Ion Exchange Ltd).
• Experienced in Monitoring and control of the Boiler water Treatment for 14TPH and Alkali Boilout and Chemical Cleaning
• Analyze of Boiler water.
• Analyze of Cooling tower water.
• Analyze of Condensate water.
• Analyze of Raw water.
• Prepare and submit the Monthly Reports of Total Water Treatment
• Operation and Monitoring of Softener 10 M3/hr. (Make: Thermax Ltd)
From October 2001 to February 2003:
Worked as a Chemist in M/s Vamshi Industries Limited, Dwarapudi having 4.5MW Bio-Mass Power Plant.
Experience in Detail:
• Experienced in Operation and Maintenance of 5 M3/hr DM Plant and 25 M3/hr Softner plant (Supplied by AquaTech Systems Pvt Ltd).
• Monitoring of CW Water Treatment for Cooling Tower (1200 M3/hr. Recirculation Rate).
• Monitoring & Control of Boiler Water Treatment for 22 TPH & 44 Kg/cm2 operating pressure Boiler.
• Analyze of Boiler water,Cooling tower water,Condensate water, DM water,and Raw water.
• Analyze of Bio-Mass (Moisture, GCV, Ash Percentage).
Personal Details
Name : K.SURYANARAYANA
Father’s Name : Anjaneyulu
Date of Birth : 20-09-1979
Nationality : Indian
Marital Status : Married
Contact Number : 089********,
Email I.D : **********@*****.**.**
Languages known : English & Telugu
Reason for Change : To gain more knowledge
References
Mr. K.Hanumantha Rao,
DGM(PP/DM Plant),M/s Nava Bharat Ventures Ltd, Paloncha, A.P.
Contact N0: 099********.
Mr. M.Kalyan,
Manager(Operations),M/s OMS Ltd.
Contact No: 096********.
Declaration
I hereby declare that above furnished information is true about best of my knowledge.
Date :
Place : K. Suryanarayana