Post Job Free
Sign in

Electrician

Location:
Victoria, TX, 77904
Salary:
23.00 per hr
Posted:
October 26, 2009

Contact this candidate

Resume:

Roland Jones *** Sierra Court

Victoria, TX *****

Home: 210-***-**** Cell: 361-***-****

*************@*****.***

Objective

To obtain a position with your company that will be equally beneficial to all parties involved.

Skills

Electrical Maintenance repairing welding machine, 120/480 volts motor control, overhead crane repair, pipe rolls, hydraulic and pneumatic solenoids, CNC machine repair, high voltage stress cone, installed MCC, VFD, PLC's. Installed and troublshooted high voltage transformer, switchgear, and substion.

Certifications

License Journeyman Electrician State of Texas, NCCER Certified, Government TWIC Card.

Education

La Marque High School, La Marque, TX

High SchoolJune 1985

Victoria College ABC Merit Workshop Program, Victoria, TX

Other - Instrumentation and Electrical, May 2000

Experience

Zackary Construction, Inivista Plant, Victoria, TX April 2008 - November 2008

Electrician

Install VFD'S, MCC, bend conduit, and terminate wires. Ran conduit underground and pull wire. Installed high voltage stress cones.

Turner Industries Group, Formosa Plastics, Point Comfort, TX June 2007 - April 2008

Maintenance Electrician

Preventive maintenance repairs on high voltage transformers, load breaks, capacitors bank and switchgear. Troubleshoot 120/480 volts control voltage. Recorded voltage and ampage reading on switchgear, motor control centers,and ups systems.

Six Flag Fiesta Texas, San Antonio, TX March 2006 - June 2007

Maintenance

Repair and preventive maintenance on rides, electrical equipment, VFD's, PLC, proximity swicthes, install motors, check gap on brake coils adjusted as needed. Troubleshoot 120/ 480 motor controls.

Fluor Global,B P Chemicals, Port Lavaca, TX July 2004 - October 2005

Maintenance Electrician

Repair HID lighting, bending conduit. Troubleshoot 120/480volts motor control, installed instrumentation transmitters and tubing bending. Preventive maintenance on high voltage transformers.

Gulf Marine Fabracation, Ingleside, TX January 2003 - March 2004

Maintenance Technician

Preventive Maintenance and repaired overhead cranes, sub arc welding machines, piperolls, manipulators. Troubleshoot PLC's, AC/DC drive motor and 120 volts motor control.

U.E.I, Dow Plant, Texas City, Tx

January 2002 - January 2003

Electrician

Prevented maintenance and repairs on pumps, motors and taken voltage reading.Troubleshooted 480 motor controls, changed oil in motor starters, replace fuses, and contactors on size 1 thru 5 motor starters.

CCC Group, Point Comfort,Alcoa Plant, TX January 1998 - January 2003

Electrician

Installed and setup VFD, PLC, MCC, terminated control wires,120 volts control troubleshooting, underground conduit for high voltage cables, stress cones , bend conduit, installing instrument transmitters and tubing. Installed high voltage substation, transformers and switchgear.

DeTar Hospital, Victoria, TX

August 1985 - May 1996

Maintenance Engineer

Preventive Maintenance and repairs on chiller, boilers, water PH samples. Worked on contruction crew building office suites, lawn care and patient care.



Contact this candidate