SUMMARY OF QUALIFICATIONS
A highly motivated bilingual (English/Spanish) professional with a solid background and knowledge in the industrial electrical/instrumentation field. Whit 9 plus year of experience in Oil & Gas industries, Power Plants and Pharmaceutical. Having a working knowledge of OSHA regulations and the ability to perform project supervision, project quality control and project reports while maintaining a cost/estimate and scheduling limitations. Complete knowledge and interpretation of Electrical and instrumentation system and knowledge in computer programs.
EMPLOYMENT HISTORY
Hovensa LLC. Jan 2010– present.
I& E CONSULTANT Facility Engineer & Project/ Execution.
To ensure the technical integrity of the projects, including compliance with the project scope, job specification, accepted good engineering design, and meeting the project requirements. Supporting the projects and facility dept. in all assigned activities including safety, detail design, procurement, construction, Qa/QC and commissioning. Supports the Field Project Manager and Facility Eng. to assure that the project, Turn-around and maintenance Work around the refinery is in compliance with local laws, Engineering Policies/Standards and our refinery standards and procedure. Also to support and offer guidance for resolution of issues regarding electrical and instruments across the Refinery. Provides “owner” oversight and direction.
• Audit and review narratives, loops, PID drawings, electrical drawing, calibration forms and E/I documentation.
• Inspection for fix Equipments, Conduits, Instruments, Wires, Grounding and process systems etc.
• I&E Walk down for PSM - PHA (Process Hazard Analysis) Revalidation.
• Project & design reviews.
• Formal Inspection and validation of the works inside the Refinery.
• Witnessing contractors’ technical system and compliance audits.
• Construction material control, Red lines and QA/Qc reports.
• Commissioning Control for instrumentation & Electrical system.
• Involve on EMOC (management of change) and validation process.
• Support facility engineering dept on design and Troubleshooting I & E system.
• Strong knowledge of Electrical & Instrumentation Codes and Standards (IEEE, ISA, NEC).
• Technical knowledge of instrument components and control systems
• Participates in QA audits of the project for all engineering elements.
• - Project engineering experience.
• Provides technical support, skills/consultation to various engineering and field personnel, including field troubleshooting when needed.
• Pursues improvements to the instrument and electrical system components and designs to improve their performance and increase plant availability.
• Knowledge on DCS and Plc control system.
• Performed small I/E design, Audited, review and approved I/E project for the Project and execution Department.
Islands Mechanical Contractor June 2008–Jan 2010
E&I Superintendent JHA Water/Energy Conservation Installation.
E&I Superintendent 24HRSG unit VIWAPA
Responsible for the erection, Construction, Pre Commissioning, Commissioning, start up and supervision of electrical and instrumentation on a new Heat Recovery Steam Generator unit in a 100MW Power Plant.
Job description & Responsibilities:
• Total cost of HRSG-24 was aprox. $70,000,000. Electrical/instrumentation job $20,000,000. Aprox.
• IMC subcontracted the foundation, but self-performed all structural, mechanical, electrical, instrumentation, boiler assembly and erection work including 0 accidents reported during project activities.
• E/I purchasing, installation, testing and troubleshoot. Scheduling E/I progress using Primavera to ensure cost vs. estimate and set -up an accurate Start-up date. Electrical and Instrumentation crew peaked at 50 technicians with three supervisors.
• Track installation/ calibration progress per client specification. Creation of Loops Folders and quality /loop-check/ calibration/commissioning and pre comissioning forms per client specification.
• Installation and calibration of instrument using hart protocol (Yarways level control, mass flow XMTr, pressure XMTr, temperature XMTr, level XMTr. DP cells, PH and conductivity xtmrs. Set up pneumatic system including control valve and pressure switch.). Calibration torque valve, Mov, Dampers, guillotine, isolation valve, positioners and feedback.
• Installation electrical equipment bldg., 13kv switch gear, substation, 4160 and 480 MCC. Auxiliary battery back –up including UPS, Bat charger and battery bank.
• Installation of fire protection system whit interface alarm on DCS.
• Installation of Plant loop system and data center communication, using fiber optic, geotropic system, cat5 and data hi-way cable to communicate between new unit-control room and plant main server.
• Installation of RMC conduit, s/s tubing, duck banks and marshaling/critical lighting panels, ground grids, EPA monitors, Process sampling panel and a chemical skid feed system
• Installation termination and testing of more than 85,000 lft of cable( control, communication, A/D signal & power cable up to 750mcm)
• Installation of DCS infi 90, programmed by ABB
• Installation of a 4160 feed pump system skid by WEG ( Isolation transformer, VFD and pumps)& a 480 condensate pump system By Siemens ( VFD and pumps)
Puertorican International Companies August 2006 – May-2008 Saint Croix, V.I.
E&I Superintendent Low Sulfur Gasoline, Hovensa Refinery (Oil & Gas refinery)
Responsible of supervision of 190 employees, including electrician, technicians, comb welders, pipe fitters, foreman and General foreman. In charge of the Execution , installation, testing, QA/QC and calibration of the LSG unit. Main gold to maintain the best schedule and hi quality of installation inside the client and refinery specifications.
Job description & Responsibilities:
• Project designed, developed and managed by Technip Italy, whit a base cost of $600,000,0000.aprox.( One of the biggest project on the Caribbean at that time)
• PIC was subcontracted to install, test and pre-commissioning the complete electrical/ instrumentation and some mechanical activities. The E/I cost for installation, testing and pre-commissioning activities was around $27,000,000 whit 0 incident reported.
• Responsible of change orders, cost and administrative activities involving a complex project.
• Supervise all field activities including the QA/QC department.
• Installation of more than 2500 instrument to ensure a safe and clean function on very hazard environments.
• Calibration of electric and pneumatics instrument and valve using hart protocol.
• Wire up a data center building whit servers, DCS. Plc and Pc station.
• Wire, test and commissioning two 13kv dual speed compressors feed by 12 ea special armored cable.
• Test and wire a variety of pumps and motors of 120 v to 4160v.
• Aluminum conduit and cable tray installation including a large amount of cabling.
• Installation and calibrate extended types of instruments to measure gas, condensate, vapors, pressure for hi and low pressure system.
• Fire and gas system installation (infrared cameras, smoke detect etc.)
• Cathodic protection installation for underground process ping ( setting By vendor)
• Installation of a large electrical equipment building modification the MCC. Per client specifications.
• Hi voltage termination
• DCS wiring and terminations.
• Responsible on QA/QC, and manage all instruments loops to be presented 100% finished whit no margin of error to the client.