Post Job Free

Resume

Sign in

Power Plant Electrical Engineer

Location:
Nagpur, MH, India
Salary:
3.2 LPA
Posted:
October 25, 2012

Contact this candidate

Resume:

Mukesh Kumar Sawner Mailing Address Permanent Address

Email: kdc7re@r.postjobfree.com C/O Mr.Pandharinath L. 355/1 Khedi,New Harsud

Contact No : +91-997******* Barapatre,Vinayal Layout, Dist. Khandwa (M.P.)

Plot.174, Warora, Dist.

Chandrapur(M.S.) Pin.450117

CURRICULUM VI AE

Career Objective :

Looking for a career which demands the best of my professional abilities, technical and analytical skills. A job which will help me in upgrade my current skills and knowledge, where I can have a good scope for learning and work on new technologies.

Professional Experience :

Total 4 year, 2 months of extensive functional experience in Commissioning,Operation & Maintenance and Testing,in Thermal Power Plant and Manufacturing,Qualities of conceptualizing, analyzing and problem solving are inherent

Academic Qualification:

B.E. in : [Electrical Engineering] with : 65.28 % First Division.

From- [Rajiv Gandhi Proudyogiki Vishwavidyalaya Bhopal ] (June 2008. ]

Diploma in : [Electrical Engineering] with : 68.16 % First Division

From-[Rajiv Gandhi Proudyogiki Vishwavidyalaya Bhopal ] (June 2005. ]

HSSC Passed with : [62.08%] from -[M.P.Board] First Division

SSC Passed from -: [M.P. Board]

Presently Working Experience :

From February. 2010 to till date

Organization

:Wardha Power Company Ltd.] KPS ., 540(4X135) MW Coal based Thermal Power Plant IPP

STG 4 nos. : 158.8 MVA, 13.8kV, Static Excitation, make: Harbin Electric Co. Ltd, CHINA.

GT : 170MVA, 13.8/220kV, OCTC, make: TBEA- China.

Steam Turbine: 135 MW, 13.73 MPa, 537 C,31 stages, double cylinder, reheator type, Condensating turbine.

Boiler : 450 tph, 14.29 MPa, 540 C, PF Boiler.

Switch Yard : 220kV, Double Bus System along with TBC with tripolar SF6 Circuit Breakers.

Department : Electrical Commissioning, Testing and Operation & Maintenance.

Designation : Electrical Engineer.

Work Exposure :

Transformers, HT & LT Switch Gear PCC and MCC, Circuit Breakers

(i.e. VCBs, ACBs, SF6 CBs, ),220kV Switch-yard equipments LA, CT, PT, OLTC, isolators,

Multi Microprocessor Protection Relay(i.e. FMR,TMR,MMR AFMR, TJ,HJ,YJ,ZJ ),

HT& LT motors, UPS, DCDB Battery charger,MOV,VFD

Multi Microprocessor Relay’s Setting and Protection Testing .

HT & LT indoor and outdoor Breakers Maintenance and Testing,

VFD Setting,Testing and Operating Maintenance,

MOV Setting,Testing and Operating Maintenance,

DCDB Battery charger earth fault voltage testing and Predictive,preventive and breakdown maintenance,

HT & LT Motors Rutting,Type and Commissioning Testing’s Predictive,preventive and breakdown

maintenance, Having good hand on practice of HT & LT Motors bearing replacement,

Conducting test runs and field trials for various equipment before they are put in service.

Immediately attend tripping of running electrical equipment.

Responsible of Breakdown & Annual Maintenance of Switch-yard equipments Transformer LA, CT, PT, OLTC, isolators,

Responsible of Annual Maintenance of Generator cooler,NGT,NGR,PT LA. Generator carbon Brushes,

Responsible of Generator test Synchronizing and Grid Synchronizing Activities .

Responsible for ESP control panel and field maintenance .

Prepared the major & minor punch items list.

Drawings study & defects finding with existing system,-

Prepared the Daily work progress report.

Previous Work Experience :

July 2008 to January 2010 date,

Organization:

‘YASHMUN EGINEERS LIMITED-Associates TATA POWER COMPANY LIMITED’

ISO 9001 :2000 COMPANY

YEL is a manufacturing and Commissioning &Testing company dealing in HT Motor, DC

Motor,Alternator,Turbo Generators installation, Commissioning and Testing on national

scale in power plant..

Department : Electrical Testing

Designation : Electrical Testing Engineer

Work Exposure :

To carry out all the routine factory acceptance tests, including the site testing and fault analysis of HV

and LV motors of all types and DC motors. Reporting to Testing Manager/Division Manager.

The initial tests of the motors i.e. Coil BDV test, HV test,tan delta, capacitance,CFT,induced

Voltage,Surge comparison Test, Dummy rotor test,Megger, winding Resistance test,

Check the working of RTD’s, BTD’s etc during the initial tests

Preparation of electrical test reports with recommendations and finalizing the repair scope with

QA and Production

Perform the stage tests on the motors

Perform No load tests on the motors

Measurement of Vibration and noise level of motors during the no load test and on site

measurements

Perform RLA studies on the motors at site and in factory

Co-ordinate with marketing and planning for customer inspections and tests

Ensure safety precautions are taken during the testing activities in factory

Ensure safe working environment at site and ensure that all the PPE’s are followed by the

technician and workmen at site.

Computer Knowledge :

Design software : AutoCAD, PLC, SCADA, AC DRIVES,

Operating systems : Windows XP/ Vista/ 07

Software knowledge : IFS,MS Office, MS Project

Skill Summary:

Excellence in electrical Operation & Maintenance and Testing

Competent leadership quality

Ability to work in team and independently

Confident, highly self-motivated and capable to work under pressure

Analyzing and problem solving.

Manpower handling

Knowledge of industry standards -- ISO 9001 :2000, .

Skill Summary:

Father Name : Late C.L Sawner

Motor Name : Late Tara Sawner

DOB : 23rd February 1983

Gender : Male

Marital status : Married

Mukesh Kumar Sawner