Resume
Name: Mohammad Jamal Uddin
Contact Address: S/O Mohammad Sadruddin
Moh-Bari Dargah
Bihar Sharif, Post
Nalanda (Dist.)
Bihar, India – 803101
Mob: - +974-******** (DOHA QATAR)
Phone: +919********* (INDIA)
E mail: **************@*****.***
Education
S.S.C Passed from B.S.E.B (Patna) in the year of 1997
Diploma Instrumentation in the year of 2007.
Advanced Application Programming. 2003
Summary
I have had 9 years’ experience in the field of instrumentation & Fire & Gas Maintenance. I am familiar with advanced instruments like SMART instruments. Furthermore, I have great trouble shooting skills and also work well either alone or with a group. I have worked in construction and maintenance fields.
Post Applied for: Fire and Gas Sr.Technician
Objectives
I am looking for a position at this Company where I can maximize my Field instrumentation & Fire and Gas skills, trouble shooting skills and leadership skill.
Personal Details
Name : Mohammad Jamal Uddin
Father’s Name : Mohammad Sadruddin
Date of Birth : 05th Jan 1983.
Place of Birth : Bihar Sharif (Nalanda)
Nationality : Indian.
Religion : Islam.
Marital Status : Single.
Languages : English, Hindi, Urdu.
Passport No : L6651566
Date of Issue : 11/11/2014
Date of expiry : 10/11/2024
Place of Issue : DOHA(QATAR)
Employment History
(1)25 April 2014 to till date
Company : Qatar petroleum (QP NGL)
Project : Call Off Contract For Maintenance of Fire & Gas System at QP NGL Mesaieed.
Employer : Tyco Qatar fire & security
Designation : Instrument Technician / fire & gas technician
Industries : natural gas to liquid Project
Responsibility : Involved in day-to-day corrective and preventive Maintenance of Electronics and Pneumatic
Instrument .fire and gas detector
(2) April 2010 to 25 July 2010
Company : ORYX-GTL
(Ras Laffan Qatar)
Employer : Tyco Qatar fire & security
Industries : Gas to liquid Project
Responsibility : Installation, maintenance, repair and calibration of a wide range of similar instrumentation, Fire & Gas equipment and systems within the Petrochemical Industry.
Good communication skills in English language.
(3)28 July 2010 to 25 December 2011
Company : Qatar petroleum(QP.NGL)Project (Qatar)
(mesaieed)
Employer : Tyco Qatar fire & security
Designation : Instrument Technician / fire & gas technician
Industries : natural gas to liquid Project
Responsibility: Calibration of pressure Transmitter. Flow Transmitter. Level Transmitter. R.T.D and Thermocouple .Control Valve. Pressure Switch. PDT Pressure differential transmitter. Deluge valve Servicing and replacing for diaphragms pilot & rubber sleeves. Pressure Switch Low Calibration. Pressure Switch high Calibration.
(4)25 Dec 2011 to 5 Feb 2012
. Company : ORYX-GTL( Ras Laffan Qatar)
Employer : Tyco Qatar fire & security
Designation : Instrument Commissioning Technician
Industries : Gas to liquid Project
Responsibility : Calibration, loop checking, Trouble shooting off all field instruments
(5)08 Feb 2012 to 20 April 2012
Company Qatar-gas,(RASLAFAN,QATAR)
Employer : Tyco Qatar fire & security
Designation : condition monitoring
Industries natural gas to liquid Project
Responsibility : vibration taken in three direction horizontal, vertical, axial parallel to shaft vibration is taken very close to the Bering. ) Temperature
(6)02nd August ’2007 - 15th March ’2010
Company : Barauni refinery Ltd.
Barauni refinery, Begusarai (Behar)
Employer : Hofincons
Designation : Instrument Technician
Industries : Oil & Gas Plant
Responsibility : Involve in Maintenance Work, Calibratio of Transmitters, Vibration Probe, Pressure Gauges Loop Checking, Functional Test, Control Monitoring Instrumentation. ESD Valve Timing checking.
Professional Skills
Instrumentation, Fire & Gas Trouble shooting – Expert
The jobs undertaken at the above mentioned organizations are as follows: -
Submission of reports of daily activities.
Working in the Oil and Gas industry, installing related instruments and working safely under the permit to work system.
Experienced In The Field of Instrumentation, Fire & Gas In Refinery, Petrochemical, Gas & Oil Plant Dealing with Erection, Calibration, Loop Checking, Pre-Commissioning, Commissioning, troubleshooting Of Pneumatic, Electro Pneumatic & Smart Types of Process Instruments.
VALVES: On-Off Valves, Control Valves with Digital (HART) Valve Positioner of Fisher Rosemount DVC 6010, 6020 & 6030, Siemens, Adamas, Neles Jamesbury ND-800/900, Valtake, Masonelian SVI, Severn Glocon. Antisurge Control Valves (CCI Drag, Fisher).Sequence Ball Valves (Orbit Valves).MOV’s Of Rotork, Biffi. (Changing Trim Kits, Lapping Overhauling, Allowable Leak Check, Bench set Calibration and Stroke Checking).
TRANSMITTERS: Pressure, Flow, Level, Temperature. SMART Transmitters Of Foxboro with HHT, Rosemount, Yokogawa Endress + Hausser Druck, H&B with Hart Communicator 268, 275, 375,475 Elsag Bailey with STT-04E, Honey Well, ABB with SFC, Vortex Flow Meters, Electromagnetic Flow Meters, and Turbine Meters. Commissioning Of Wet Leg Type Level Transmitter (D/P) With Filling Sealing Liquid.
LEVEL TROLL :( Displacement Transmitters) Of Magnetrol, Masonelian, Foxboro Eckardt, & Tokyo Kaesio.
SWITCHES: Pressure, Temperature, Level of Asco, Ashcroft, ITT Barton, Sor, Switzer, Magnetrol, Spirax Sarco, Tokyo Keiso.
Flammable gas detector
Heat detector tests
Smoke detector tests
Inergen Systems and CO2 system
FM 200 Suppression System
Manual call point tests.
Hydrogen Sulphide gas detector
Hydrogen supplied gas detector tests
Field warning system tests
VESDA system tests
Building Fire Alarm system tests
Flame detector test
Deluge valve test
Sprinkler system test
Foam fire suppression system
Simplex Fire Alarm Panel.
Safety Showers.
Simplex Network / Other F&G Plant-wide Networks.
DCS communication interlink test
Toxic gas detector test
Linear Heat Detectors
Open Path Gas Detectors
Flame Detectors (UV/IR)
Job Description :
Carry out general day to day Preventive Maintenance Job, Break down Job, Condition Based Jobs shut down jobs and pre-commissioning & Start up activities.
Understand and Interpret approved for Construction drawings of consultant for field installation of Instruments, Impulse tubing, Cable Junction boxes, Support etc.
Carryout calibration of instruments and prepare test certificate.
Carryout megger and continuity test of instrument/electrical cables.
Lay and Terminate instrument and power cables in field and control room.
Experienced in the installation & Calibration of speed sensor (Voith Turbo).
Familiar with the mechanical inspection of newly installed instrument as per client requirement.
Carryout cross-wing and inter panel wiring in the control room panels for signal marshalling, Relay logic, Fire & Gas Panels, Operator Control Desk etc.
Gained Experience in Calibration of smart Transmitter for Pressure, Differential pressure, Temperature, Level Measurement of reputable manufacturers such as Rosemount (Model 3051 C), Yokogawa (EJA Series), Honeywell (300 Series). Familiar with use and application of communicators using HART protocol (275) and Yokogawa BT-200 of EIA Series, SFC – Honeywell.
Familiar with installation of Ultrasonic flow meter for Gas/Oil measurement in header line.
Experience in installation & checking various types’ smoke detectors, heat detectors, LEL detectors and toxic gas detectors. Flame detector.
(SD) Smoke Detectors for troubleshooting
(HD) Heat Detectors for troubleshooting & Alarm testing
& Alarm testing,
(FD) Flame detector for troubleshooting & Alarm testing
(MAC) Manual call point for troubleshooting & Alarm testing
(XL) Beam. Indicator & Hotter for troubleshooting & Alarm testing
Analogue and Addressable Fire Control Panels and
(HSSD) VESDA air sampling smoke detection system.
(GDT) Toxic gas detector for troubleshooting & calibration,
(GDF) Flammable gas detector for troubleshooting & calibration
Point, open path, IR type gas beam detector,
(DV) Deluge Valve and Deluge Skid, troubleshooting & calibration for pressure switches (PSL, PSLL, PSH, PSHH )
Fire & Gas System:
HC & Toxic Gas Detectors: Dragger, General Monitor, Honeywell, Detcon, Crowcon. Oldham, Honeywell optima+
Fire & Smoke Detectors : Tyco, Cerberus, Kidde, Autronica etc
HSSD Systems : Vesda and Stratos.
Fire Fighting System : Deluge Valve and Deluge Foam Skid (Fusible bulb, Springular system), Functional test & servicing of valves. Closed Tank Rim seal nitrogen system, Fire Fighting System
old
Fixed fire and Gas detection products:
Manufacturer
Type of detector
Models
DRAEGER SAFETY - UK
Flammable Gas detectors
1). Polytron 2 IR – 334 & 340
2). Polytron IR EX
3). Polytron 2 XP EX
4). Polytron FX
5). Polytron IR 7000
6). Polytron IR 3000
7). Polytron EX
OPEN PATH - Flammable Gas detector
1). Open Path Pulsar 1
2). Open Path Pulsar 2
Toxic Gas detectors
1).Polytron 2 XP TOX
2). Polytron 3000
3). Polytron 8000
4). Polytron TX
Flame detector
1). IR Flame detector
2). UV Flame detector
3). UVIR Flame detector
Attend Meetings With Clients And Subcontractors Regarding Work Progress And Technical Aspects As Required. Resolve Technical Queries On Discrepancies That May Occur On Site And Make FDM (Field Design Modification).
P&ID, Instrument Location And General Operating Floor Plant Prepares Turn-Over Packages Documents For Mechanical Completion That Consists Of All Engineering And Construction Disciplines Such As As-Built, Test Reports, Punch Lists. Vendor Drawing & Other Related Documents
Working with following Master Instrument
Druck DPI 601
Decade Resistance Box 1051,8000
Hand pump Transcat Hyraulic
GE Druck DPI 812 RTD Loop Calibrator
GE Druck DPI 822 Thermocouple
Hart Communicator 375&475
Fluke & Duck Calibrator, Digital Pressure Indicator (DPI-610)
Dead weight tester,
ABB Communicator (HT-691)
Fluke MultiMate
Training & Semin
1. Emergency Breathing System (EBS)
Safety Training
2. iosh (Institution of Occupational Safety and Health) 2019
3. Onshore Safety Induction.
4. Permit to work System (PTW).
5. Confined space Entry
6. Working at Height
7. Fire & safety watch
8. H2s/BA awareness
Present Address : Post Box # 47679
: Doha, Qatar.
: Mobile no 009**********
: Mohammad Jamal Uddin