PROJECT

APT RENOVATION

2 2ND BOARD SUBMITTAL 7/29/22

# ISSUE DESCRIPTION DATE

3 FOR CLIENT REVIEW 8/28/22

4 FINAL BID SET 9/29/22

A-000

GENERAL SHEET

PROJECT INFORMATION

DRAWINGS INDEX

GENERAL

A-000 - GENERAL SHEET

A-001 - SPECIFICATIONS

DEMOLITION

D-101 - DEMO PLAN

ARCHITECTURAL

A-101 - ARCHITECTURAL PLAN

A-601 - ENLARGED BATH-1

A-602 - ENLARGED BATH-2

A-603 - ENLARGED KITCHEN

A-604 - MISC MILLWORK

A-901 - CONSTRUCTION DETAILS

A-902 - CONSTRUCTION DETAILS

MECHANICAL

M-101 - MECHANICAL PLAN

PLUMBING PLAN

P-101 - PLUMBING PLAN

(D) - DEPTH / DEEP

(E) - EXISTING

(H) - HEIGHT / HIGH

(L) - LENGTH / LONG / WIDE

(N) - NEW

AFF - ABOVE FINISHED FLOOR

B.O. - BOTTOM OF

CL - CENTERLINE

CLG - CEILING

CLR - CLEAR (FINISH TO FINISH)

DBL - DOUBLE

DR - DOOR

DHW - DOMESTIC HOT WATER

DN - DOWN

FF - FINISH FLOOR

FPSC - FIRE PROTECTED W/ SELF CLOSER

F.O. - FACE OF

F.O.F. - FACE OF FINISH

FR - FIRE RATED

GWB - GYPSUM WALL BOARD

HDR - HEADER

IGU - INSULATED GLASS UNIT

LT - LIGHT

MTL - METAL

OC - ON CENTER

OFCI - OWNER FURNISH / CONTRACTOR INSTALL

OPP - OPPOSITE

PT - PRESSURE TREATED

SIM - SIMILAR

SS - STAINLESS STEEL

SW - STORMWATER

T.O. - TOP OF

UNO - UNLESS NOTED OTHERWISE

VIF - VERIFY IN FIELD

W/ - WITH

ABBREVIATIONS

PROJECT ADDRESS

111 FULTON ST PH110

NEW YORK, NY 10038

SCOPE OF WORK

INTERIOR RENOVATION OF PRIVATE

APARTMENT AND MISCELLANEOUS EXTERIOR

WORK ON PRIVATE TERRACE.

(1) WORK SHALL BE COMPLETED IN

ACCORDANCE WITH THE FOLLOWING CODES OR

THE MOST UPDATED VERSION IN ADDITION TO

ALL CODES, RULES REGULATIONS, OF NEW YORK

CITY, NEW YORK STATE, AND ADA CODE:

2014 NYC MUNICIPAL BUILDING CODE

2014 NYC MECHANICAL CODE

2014 NYC PLUMBING CODE

2011 NYC ELECTRICAL CODE

2014 NYC FIRE CODE

ANSI 117.5 2007 ACCESSIBILITY CODE

(2) THESE DRAWINGS INDICATE THE GENERAL

SCOPE OF THE PROJECT, BUT DO NOT

NECESSAIRLY INDICATE OR DESCRIBE ALL ITEMS

REQUIRED FOR FULL PERFORMANCE AND

COMPLETION OF THE WORK. ITEMS NOT SHOWN

OR SPECIFIED, BUT NECESSARY FOR PROPERY

CONSTRUCTION OF ANY PART OF THE WORK,

SHALL BE INCLUDED AS IF THEY WERE

INDICATED ON THE DRAWINGS.

(3) CONTRACTOR SHALL BE RESPONSIBLE FOR

VERIFYING ALL DIMENSIONS AND EXISTING

CONDITIONS BEFORE STARTING WORK. REPORT

ANY DISCREPANCIES TO THE ARCHITECT.

CONTRACTOR SHALL NOT MAKE MODIFICATIONS

TO THE DESIGN TO ACCOMODATE FIELD

CONDITIONS, OR FOR ANY OTHER REASON

WITHOUT CONSULTING THE ARCHITECT.

CONTRACTOR SHALL NOTIFY ARCHITECT OF

EXISTING FIELD CONDITIONS DISCOVERED THAT

DIFFER THAN THEN THE REQUIREMENTS HEREIN.

(4) IT IS THE CONTRACTOR'S RESPONSIBILITY TO

ENSURE THAT EVERY ASPECT OF THE

CONSTRUCTION IS PERFORMED IN STRICT

CONFORMANCE WITH THE PLANS,

SPECIFICATIONS, AND CODE REQUIREMENTS.

ANY NON-COMPLIANT WORK SHALL BE REMOVED

AND REPLACED AT THE CONTRACTOR'S OWN

COST.

(5) CONTRACTOR SHALL BE RESPONSIBLE FOR

THE PROTECTION OF ALL EXISTING AND NEW

BUILDING COMPONENTS, FINISHES, AND

MATERIALS WITHIN THE CONSTRUCTION AREA.

DAMAGE WILL BE REPAIRED OR REPLACED TO

THE SATISFACTION OF THE OWNER AT THE

CONTRACTOR'S COST.

(6) CONTRACTOR SHALL BE RESPONSIBLE FOR

OBTAINING ALL PERMITS AND INSPECTIONS FOR

CONSTRUCTION, INCLUDING BUT NOT LIMITED TO

BUILDING/DEMOLITION, FIRE, PLUMBING,

SPRINKLER, MECHANICAL, AND ELECTRICAL

PERMITS. CONTRACTOR TO PAY FOR ALL

APPLICABLE FEES. CONTRACTOR TO OBTAIN

SIGN-OFFS FROM THE AUTHORITIES HAVING

JURISDICTION AS REQUIRED BY CODE.

(7) CONTRACTOR SHALL CONFIRM THAT

BUILDING OPENING CLEARANCES ARE

SUFFICIENT FOR DELIVERY AND INSTALLATION

OF WORK.

(8) CONTRACTOR SHALL HAVE SOLE

RESPONSIBILITY FOR ANY DAMAGE OR INJURIES

CAUSED BY OR DURING THE EXECUTION OF THE

WORK. SAFETY, MEANS, AND METHODS IS THE

SOLE RESPONSIBILITY OF THE CONTRACTOR.

(9) CONTRACTOR TO PROTECT ALL PUBLIC

SPACES DURING CONSTRUCTION AND

DEMOLTION WHEN DELIVERING MATERIALS AND

EQUIPMENT AND REMOVING REFUSE, RUBBISH,

AND REQUIPMENT.

(10) THE CONSTRUCTION AREA PREMISES MUST

BE MAINTAINED IN A NEAT AND ORDERLY

CONDITION AND BE KEPT FREE FROM

ACCUMULATION OF DUST AND DEBRIS DURING

THE ENTIRE CONSTRUCTION PERIOD.

GENERAL NOTES

(11) CONTRACTOR SHALL COORDINATE AND

CONFIRM CLEARANCE REQUIREMENTS FOR

INSTALLATION OF ALL TRADES AND REPORT ANY

DISCREPANCIES TO THE ARCHITECT PRIOR TO

COMMENCING WORK.

(12) RESERVED

(13) CONTRACTOR SHALL RETAIN, COMPILE, AND

ISSUE ALL MANUALS, WARRANTIES, AND SERIAL

NUMBERS TO THE OWNER.

(14) CONTRACTOR SHALL INQUIRE WITH

BUILDING SUPERVISOR OR PROPERTY MANAGER

REGARDING CONSTRUCTION CONDITIONS,

BUILDING RULES AND REGULATIONS PRIOR TO

COMMENCEMENT OF WORK. CONTRACTOR

SHALL INQUIRE WITH SUPERINTENDENT FOR

REVIEW PRIOR TO COMMENCEMENT OF

CONCEALING WORK.

(15) CONTRACTOR TO ADHERE TO ALL CITY AND

STATE GUIDELINES FOR WORKING UNDER COVID

RESTRICTIONS.

(16) CONTRACTOR SHALL PROHIBIT THE USE OF

AIRBONE ODOR AND FUME EMITTING

CHEMICALS. FINISHING PRODUCTS MUST MEET

STATE VOC REGULATIONS AND STANDARDS.

BID REQUIREMENTS

(1) ONLY THE FOLLOWING MATERIALS ARE

OWNER-FURNISHED, CONTRACTOR-INSTALLED

AND ARE NOT TO BE INCLUDED IN THE BID:

(A) WALL AND FLOOR TILE

(B) SOLID STONE / QUARTZ SLAB MATERIAL

(C) EXTERIOR FINISH PAVERS

(D) INTERIOR LIGHTING AND IN-CABINET LIGHTING

(E) PLUMBING FIXTURES

(F) BATHROOM ACCESSORIES

(G) KITCHEN APPLIANCES

THE CONTRACTOR'S BID AMOUNT SHALL

INCLUDE THE INSTALLATION COST FOR THESE

MATERIALS IN ACCORDANCE WITH THE

DRAWINGS AND SPECIFICATIONS. THE

CONTRACTOR'S BID AMOUNT SHALL INCLUDE ALL

GENERAL PROJECT EXPENSES SUCH AS

OVERHEAD AND PROFIT. THE CONTRACTOR

SHALL BE RESPONSIBLE FOR COORDINATING

AND RECEIVING THE OFCI MATERIALS. THE

CONTRACTOR'S BID SHALL INCLUDE

MISCELLANEOUS MATERIALS AND LABOR

REQUIRED FOR A COMPLETE INSTALLATION:

ITEMS SUCH AS ADHESIVES, GASKETS, WIRING,

SUBSTRATES, FASTENERS, GROUT, AND

MANUFACTURER RECOMMENDED FINISH

COATINGS ARE TO BE INCLUDED.

(2) THE CONTRACTOR'S BID SHALL PROVIDE

ITEMIZED AMOUNTS FOR THE FOLLOWING SCOPE

OF WORK, INCLUSIVE OF PROFIT AND OVERHEAD:

(A) EXTERIOR ALUMINUM SCREEN WALL

(B) SPA PLATFORM AND STAIRS

(C) MILLWORK CABINETRY AND WOOD PANELING

(D) MECHANICAL DUCTWORK AND DIFFUSERS

(3) CONTRACTOR'S BID SHALL INCLUDE ITEMIZED

PRICING FOR ADD-ALTERNATE #1 AND #2 AND

DEDUCT-ALTERNATE #1. REFER TO SKETCHES

FOR ADDITIONAL INFORMATION.

ILLUSTRATIVE IMAGE OF KITCHEN FOR REFERENCE ONLY - DO NOT BID OR BUILD THIS IMAGE ILLUSTRATIVE IMAGE OF BATH-1 FOR REFERENCE ONLY - DO NOT BID OR BUILD THIS IMAGE ISSUE TITLE

FINAL BID SET SEPTEMBER 29TH, 2022

PERMIT REQUIREMENTS

CONTRACTOR SHALL BE RESPONSIBLE FOR

FILING FOR AN ELECTRICAL WORK PERMIT

AND A LIMITED ALTERATION APPLICATION FOR

PLUMBING WORK WITH THE NYC DEPARTMENT

OF BUILDINGS.

2

2

2

2

1 BID SET 6/1/22

139 FULTON STREET #810 NY, NY 10038

******@*****************.***

ANDREARCHITECTURE.COM

(PH) 917-***-****

ARCHITECT

ANDRE ARCHITECTURE DPC

© 2021 ANDRE ARCHITECTURE

111 FULTON STREET PH110

NEW YORK, NY 10003

PROJECT

APT RENOVATION

2 2ND BOARD SUBMITTAL 7/29/22

# ISSUE DESCRIPTION DATE

3 FOR CLIENT REVIEW 8/28/22

4 FINAL BID SET 9/29/22

A-001

SPECIFICATIONS

DIVISION 8

GLAZING

(1) ALL INTERIOR GLAZING TEMPERED OR

LAMINATED. REFER TO DRAWINGS.

DIVISION 7

DRYWALL

(1) ALL NEW DRYWALL TYPE (X) 5/8" THICK. USE

5/8" FIRE RATED WHERE NOTED ON DRAWINGS.

USE 5/8" MOISTURE RESISTANT DRYWALL IN

BATHROOMS AND LAUNDRY ROOM.

(2) USG LEVEL 4 FINISH THROUGHOUT.

(3) OUTSIDE CORNERS SHALL HAVE METAL

CORNER BEADS. METAL CASING BEADS SHALL BE

INSTALLED WHERE DRYWALL ADJOINS OTHER

MATERIALS AND JOINT IS NOT CASED.

(4) DO NOT ATTACH GYPSUM WALL BOARD TO TOP

TRACK OF METAL FRAMING, ONLY TO VERTICAL

STUDS

FLEXIBLE GYPSUM BOARD (FGB)

(1) FURNISH AND INSTALL FLEXIBLE GYPSUM

BOARD WHERE NOTED ON DRAWINGS. BASIS-OF-

DESIGN GOLD BOND HIGH FLEX GYPSUM BOARD,

1/4" THICKNESS. INSTALL ACCORDING TO

MANUFACTURER'S INSTRUCTION TO ACHIEVE

BENDING RADIUS AS INDICATED ON DRAWINGS.

WETTING MAY BE REQUIRED.

PAINTING

(1) ALL PAINTING TO CONTAIN ZERO VOLATILE

ORGANIC COMPOUNDS (VOC). NO INTERIOR OIL-

BASED PAINT WILL BE PERMITTED.

WOOD FLOOR FINISH (WDFF)

(1) FURNISH AND INSTALL UV-CURED

WATERBORNE FINISH, PROCOAT, RADCOAT IN

ULTRAMATTE SHEEN IN ACCORDANCE WITH

MANUFACTURER REQUIREMENTS AND WRITTEN

INSTRUCTIONS. SUBSTITUTIONS NOT PERMITTED.

(2) THIS PRODUCT REQUIRES UV CURING

EQUIPMENT, SPECIAL EQUIPMENT MUST BE

PROVIDED BY CONTRACTOR. A KNOWN LOCAL

SUBCONTRACTOR WITH SPECIALITY EQUIPMENT

AND APPLICABLE EXPERIENCE IS LISTED BELOW.

(3) PREFERRED CONTACT FOR LOCAL INSTALLER:

BRIAN PRUSIK, RETAILER FLOORING SOLUTIONS,

CELL NUMBER IS 315-***-****. EMAIL ADDRESS IS

*****@**********.***

TILE FINISH TRIM (TFT)

(1) FURNISH AND INSTALL TILE EDGE TRIM WHERE

INDICATED ON DRAWINGS. BASIS-OF-DESIGN

SCHLUTER-SCHIENE, FINISH AS NOTED ON

DRAWINGS. NO PRODUCT SUBSITUTIONS

PERMITTED.

(2) FINISH EDGE FLUSH TO TILE, CONTRACTOR TO

COORDINATE PROFILE HEIGHT REQUIREMENTS.

DIVISION 6

INTERIOR TRIM AND CARPENTRY

(1) ALL MATERIAL DOUGLAS FIR OR MDF, NON

FINGER JOINTED, UNLESS NOTED OTHERWISE. NO

SPLICES ALLOWED ON RUNS LESS THAN

FOURTEEN FEET (14') IN LENGTH.

CUSTOM MILLWORK

(1) CUSTOM MILLWORK INCLUDES CABINETRY,

SHELVING, BUILT-IN FURNITURE, AND SIMILAR

WOODWORK ITEMS NOT INDICATED AS NIC OR

OWNER-FURNISHED. ALL MATERIALS AND FINISHES

TO BE PROVIDED AS NOTED ON PLANS. ALL

MATERIALS AND FINISHES TO BE SEALED AND

FINISHED ON ALL SIDES. ALL NAILS, SCREWS,

GLUE, OR ANY OTHER MEANS OF ASSEMBLING THE

CABINETRY NOT TO BE VISIBLE. ALL MILLWORK

FORMALDEHYDE FREE.

(2) 1/8" MAX BUTT JOINT TYPICAL. END SHIMS,

SPACERS, AND GAPS NOT TO EXCEED 1/4".

(3) ALL CABINETRY TO BE PLYWOOD, FRAMLESS

BOX CONSTRUCTION. FINISH EXPOSED EDGES OF

PLYWOOD BOX TO MATCH INTERIOR.

(4) DRAWER FRONTS AND DOOR FRONTS TO BE

MINIMUM 3/4" THICK, FINISH TO MATCH EXTERIOR

ON ALL SIDES.

(5) ALL DRAWER BOXES TO BE MINIMUM 3/4" THICK

PLYWOOD WITH EASED EDGES AND CORNERS,

DOVETAIL CONSTRUCTION. FURNISH BLUMOTION,

SELF-CLOSING, UNDERMOUNT DRAWER GLIDES.

(6) ALL DOOR FRONTS TO BE FURNISHED WITH

INSET EUROPEAN STYLE HINGES, SOFT-CLOSE.

(7) WHERE SHOP APPLIED LACQUER IS NOTED ON

DRAWINGS, FINISH TOP COAT TO BE SOLVENT-

BASED PRE CATALYZED LACQUER, CATALYZED

LACQUER, OR CONVERSION VARNISH. FINISH TO BE

APPLIED AFTER DOORS HINGES AND HARWARE

HAS BEEN SET. NO RAW WOOD LEFT UNFINISHED.

(8) PROVIDE SHOP DRAWINGS, PRODUCT AND

MANUFACTURER CUT SHEETS, AND SAMPLES OF

EXPOSED METALS INCLUDING HARDWARE.

COMPOSITE DECK (TREX)

(1) FURNISH AND INSTALL COMPOSITE DECKING

WHERE NOTED ON DRAWINGS. BASIS-OF-DESIGN,

TREX SELECT - WINCHESTER GREY. PROFILE IS A

COMBINATION OF SQUARE AND GROOVED WITH

CONCEALED FASTERNERS, REFER TO DRAWINGS.

WHERE FASTENERS OCCUR, PROVIDE OIL-RUBBED

STAINLESS STEEL OR SIMILAR.

(2) ALUMINUM FRAMED SUPPORT SPACING NOT TO

EXCEED 16" ON CENTER, WITH THERMOPLASTIC

SHIMS WHEREVER FRAME IS IN CONTACT WITH

GROUND SURFACE.

(3) THIS SPECIALITY CUSTOM FURNITURE MUST BE

MADE REMOVABLE WITHOUT THE USE OF SPECIAL

TOOLS AND EQUIPMENT, CONFIRM DESIGN INTENT

WITH ARCHITECT AND OWNER PRIOR TO

COMMENCEMENT OF WORK.

DIVISION 1

RESERVED

(1) RESERVED

DIVISION 9

DIVISION 2

DIVISION 3

DIVISION 4

DIVISION 5

RESERVED

(1) RESERVED

RESERVED

(1) RESERVED

RESERVED

(1) RESERVED

METAL FRAMING (NON-BEARING)

(1) ALL METAL FRAMING TO BE TRUE, LEVEL,

AND PLUMB. INSTALL FRAMING MEMBERS

PLUMB WITHIN 1/4" IN 10'. INSTALL EACH

FRAMING MEMBER SO FASTENING SURACES

DO NOT VARY MORE THAN 1/8".

(2) DESIGN LOADS: 5 PSF MINIMUM OR AS

REQUIRED BY THE INTERNATIONAL BUILDING

CODE. DESIGN FRAMING SYSTEM TO

ACCOMODATE DEFLECTION OF PRIMARY

BUILDING STRUCTURE AND CONSTRUCTION

TOLERANCES.

(3) PROVIDE SLIP-TYPE HEAD JOINTS:

SINGLE LONG-LEG RUNNER SYSTEM, TOP

RUNNER WITH 2" DEEP FLANGES IN

THICKNESS NOT LESS THAN INDICATED FOR

STUDS, INSTALLED WITH THE STUDS FRICTION

FIT INTO TOP RUNNER AND WITH

CONTINUOUS BRIDGING LOCATED WITHIN 12

INCHES OF THE TOP OF STUDS TO PROVIDE

LATERAL BRACING.

DEFLECTION TRACK, STEEL SHEET TOP

RUNNER MANUFACTUED TO PREVENT

CRACKING OF FINISHES APPLIED TO INTERIOR

PARTITION FRAMING RESULTING FROM

DEFLECTION OF STRUCTURE ABOVE; IN

THICKNESS NOT LESS THAN INDICATED FOR

STUDS AND IN WIDTH TO ACCOMODATE

DEPTH OF STUDS.

(4) BRIDIGING MEMBERS NOT LESS THAN .054"

THICK WITH MINIMUM FLANGE NOT LESS THAN

1/2" WIDE. CLIP ANGLES NOT LESS THAN 1-1/2"

X 1-1/2".

(5) PROVIDE ISOLATION STRIPS WHERE METAL

FRAMING IS IN CONTACT WITH EXTERIOR

WALLS.

(6) FOR DOOR FRAMING SECURELY FASTERN

VERTICAL STUDS AT JAMBS TO JAMB ANCHOR

CLIPS ON DOOR FRAMES; INSTALL RUNNER

TRACK SECTION (FOR CRIPPLE STUDS) AT

HEAD AND SECURE TO JAMB STUDS. INSTALL

TWO STUDS AT EACH JAMB. EXTEND JAMB

STUDS TO UNDERSIDE OF OVERHEAD

STRUCTURE.

(7) DO NOT BRIDGE BUILDING CONTROL AND

EXPANSION JOINTS.

SMOKE/CARBON MONOXIDE DETECTORS

(1) SMOKE/CARBON MONOXIDE DETECTORS OR

DEVICES SHALL BE INSTALLED IN ORDINANCE

WITH THE HOUSING MAINTENANCE CODE,

MULTIPLE DWELLING LAW, THE NEW YORK CITY

BUILDING CODE, THE NEW YORK CITY

ELECTRICAL CODE AND THE NFPA 72.

(2) SMOKE DETECTORS AND CARBON MONOXIDE

DETECTORS MAY BE COMBINED PROVIDING THE

DEVICES COMPLY WITH THE PROVISIONS OF

TITLE 28 OF THE ADMINISTRATIVE CODE OF THE

CITY OF NEW YORK AND ANY APPLICABLE RULES

PROMULGATED THEREUNDER.

(3) EACH SMOKE/CARBON MONOXIDE DETECTOR

SHALL BE INSTALLED IN ACCORDANCE WITH

REFERENCE STANDARD UL 2034 AND UL 2075 OF

THE NEW YORK CITY BUILDING CODE.

(4) EACH SMOKE/CARBON MONOXIDE DETECTOR

SHALL BE INSTALLED OUTSIDE OF EACH

SLEEPING ROOM IN THE IMMEDIATE VICINITY OR

WITHIN 15'-0" OF THE ENTRANCE TO A SLEEPING

ROOM; INSIDE EACH SLEEPING ROOM; AND ON

EACH STORY WITHIN A DWELLING UNIT,

INCLUDING BELOW GRADE STORIES AND

PENTHOUSES AS PER 908.7.1.1.1

(5) EACH SMOKE/CARBON MONOXIDE DETECTOR

SHALL BE OF A TYPE THAT ALLOWS FOR READILY

TESTING OF SUCH DEVICE.

(6) DUPLEX UNITS SHALL HAVE A DEVICE

LOCATED ON EACH LEVEL IF ONLY ONE MEANS

OF EGRESS IS PROVIDED FOR EACH LEVEL.

(7) CEILING MOUNTED DEVICES SHALL BE A

MINIMUM DISTANCE OF 4" FROM ANY WALL. WALL

MOUNTED DEVICES SHALL BE A MINIMUM OF 4"

TO A MAXIMUM OF 12" FROM THE CEILING.

(8) EACH DWELLING UNIT SHALL BE EQUIPPED

WITH AN APPROVED TYPE SMOKE/CARBON

MONOXIDE DETECTOR DEVICE RECEIVING

PRIMARY POWER FROM THE BUILDING WIRING

WITH NO SWITCHES IN THE CIRCUIT OTHER THAN

THE OVER CURRENT DEVICE PROTECTING THE

BRANCH CIRCUIT AS PER NEW YORK CITY

BUILDING CODE SEC. 907.2.10.2 THROUGH

907.2.10.4

(9) EXISITNG BUILDINGS THAT ARE NOT

EQUIPPED WITH HARDWIRED CONENCTIONS

SHALL BE SUPPLIED WITH BATTERY OPERATED

DEVICES.

(10) SUCH SMOKE/CARBON MONOXIDE

DETECTOR MUST BE EITHER THE IONIZATION

CHAMBER TYPE OR THE PHOTOELECTRIC

DETECTOR TYPE AS PER NEW YORK CITY

BUILDING CODE SECTION 907 AND 908.

(11) A "CERTIFICATE OF SATISFACTORY

INSTALLATION FOR SMOKE/CARBON MONOXIDE

DETECTORS" MUST BE FILED WITH THE DIVISION

OF CODE ENFORCEMENT HPD 10 DAYS AFTER

INSTALLATION.

(12) WRITTEN INFORMATION OF TESTING AND

MAINTENANCE OF THE DEVICES SHALL BE

PROVIDED TO THE DWELLING UNIT OWNER.

(13) IN MULTIPLE DWELLINGS (R-2) SMOKE

ALARMS SHALL BE ABLE TO SUPPORT VISIBLE

ALARM PER ANSI A117.1

DIVISION 28

MINERAL WOOL INSULATION

(1) PROVIDE MINERAL STONE WOOL INSULATION

AT ALL NEW INTERIOR WALLS. FILL ENTIRE

CAVITY BETWEEN STUDS, NO GAPS PERMITTED.

(2) FURNISH ROCKWOOL OR THERMAFIBER

PEDESTAL PAVER SYSTEM (PPS)

(1) PROVIDE SHIM AND LEVEL SYSTEM WHERE

NEW PAVERS OCCUR, REF TO DRAWINGS.

BASIS-OF-DESIGN, SCHLUTER TROBA-LEVEL LV3

AND PL 10 WITH 1/8" TAB SPACING. SYSTEM

MUST BE RATED FOR AT LEAST 1000 LBS.

PRODUCT SUBSTITUTIONS ARE ACCEPTABLE

WITH ARCHITECT APPROVAL.

(3) HEIGHT INSTALLATION WILL VARY BUT IS

APPROXIMATELY 7/8", REFER TO DRAWINGS

FOR ADDITIONAL INFORMATION.

(4) PROVIDE COMPLETE SYSTEM INCLUDING

TABS, LEVELERS, AND SHIMS AS NEEDED FOR

COMPLETE LEVEL AND FLUSH INSTALLATION.

BONDED WATERPROOFING MEMBRANE (WP1)

(1) INSTALL SCHLUTER KERDI BONDED

WATERPROOFING SYSTEM PER MANUFACTER

REQUIREMENTS. FURNISH ALL INSTALLATION

AND TRANSITION DETAILS FOR COMPLETE

SYSTEM.

(2) INSTALL AT SHOWER FLOOR AND FULL-

HEIGHT AT SHOWER WALLS.

(3) PROVIDE A 24 HOUR FLOOD TEST AT

SHOWER PAN BEFORE SETTING TILE TO

DETERMINE WATERTIGHTNESS. DOCUMENT

WITH PHOTOS AND WRITTEN REPORT.

LIQUID WATERPROOFING MEMBRANE (WP2)

(1) FURNISH AND INSTALL LATICRETE 9235

WATERPROOFING MEMBRANE PER

MANUFACTURER REQUIREMENTS.

(2) INSTALL AT BATHROOM FLOOR AND UP 4"

MIN AT PERIMETER WALLS AND SHOWER CURB.

LIGHTING

(1) NOT LESS THAN 90 PERCENT OF THE

PERMANENTLY INSTALLED LIGHTING FIXTURES

SHALL USE LAMPS WITH AN EFFICACY OF AT

LEAST 65 LUMENS PER WATT, OR HAVE A TOTAL

LUMINAIRE EFFICACY OF AT LEAST 45 LUMENS

PER WATT.

DIVISION 26

2

PLUMBING

1) ALL COLD & HOT WATER SUPPLY PIPING

SHALL BE COPPER TUBING, TYPE "L" PER ASTM

B88 WITH WROUGHT COPPER FITTING PER ANSI

B16.22 JOINED WITH SOLDER CONFORMING TO

ASTM B32 (95% TIN/ 5% ANTIMONY)

(2) ALL SANITARY DRAINAGE AND VENT PIPING

SHALL BE NO HUB CAST IRON SOIL PIPE PER

ANSI 112-5-71.

(3) ALL POTABLE PIPING SHALL BE INSULATED

WITH OWENS CORNING FIBERGLASS PIPE

INSULATION ASJ/SSL-11. INSULATION THICKNESS

SHALL BE 1" FOR PIPE SIZES 2" AND SMALLER

AND SHALL BE 1-1/2" THICK FOR PIPE SIZES 2-1/2"

THROUGH 4". ALL PIPING, FITTINGS, VALVES, ETC.

SHALL BE PROPERLY INSULATED TO PREVENT

SWEATING AND/OR HEAT LOSS.

(4) CHANGES IN DIRECTION IN DRAINAGE PIPING

SHALL BE MADE WITH THE APPROPRIATE USE OF

45 DEGREE WYES, LONG SWEEPS, SHORT

SWEEPS, SIXTH, QUARTER, EIGHTH OR

SIXTEENTH BENDS, OR BY A COMBINATION OF

THESE OR EQUIVALENT FITTINGS.

(5) SANITARY TEES AND QUARTER BENDS MAY

BE USED IN DRAINAGE LINES ONLY WHERE THE

DIRECTION OF FLOW IS FROM THE HORIZONTAL

TO THE VERTICAL.

(6) SHORT SWEEPS WILL BE PERMITTED IN

DRAINAGE PIPING 3 INCHES DIAMETER OR

LARGER FOR ANY OFFSETS EITHER HORIZONTAL

OR VERTICAL.

(7) ALL PIPING SHALL BE PROPERLY AND

SECURELY FASTENED AND/OR HUNG SO AS NOT

TO COME IN CONTACT WITH NOR BE SUPPORTED

BY ANYTHING OTHER THAN THE PROPER AND

INTENDED SUPPORTS MENTIONED.

(8) ALL WASTE LINES SHALL BE PROPERLY

PITCHED MINIMUM 1/4" PER FOOT AND PIPED TO

INSURE TOTAL DRAINAGE AND SO AS NOT TO

CREATE NOR FORM TRAPS.

(9) NO SUPPLY WATER LINES SHALL USE

FLEXIBLE OR BENDABLE FITTINGS.

(10) PROVIDE ANTI-SCALD VALVES FOR TUB &

SHOWERS. VERIFY & COORDINATE WITH

ARCHITECT'S FIXTURE SELECTION PRIOR TO

ORDER, PURCHASE & INSTALLATION OR

TUB/SHOWER MIXING VALVES.

(11) ALL DOMESTIC WATER LINES LOCATED IN

NON-HEATED AREAS ARE TO BE HEAT TRACED &

INSULATED TO AVOID FREEZING (ATTICS,

CRAWLSPACES, EXTERIOR WALL, ETC.)

LEAK DETECTION SYSTEM (LDS)

(1) WATTS INTELLIFLOW SERIES A2C-M1

AUTOMATIC WASHING MACHINE WATER SHUTOFF

VALVE WITH LEAK SENSOR. AUTOMATIC VALVES

OPEN WHEN ELECTRICAL CURRENT IS DETECTED

AND CLOSE WHEN NO CURRENT IS DETECTED

(THE MACHINE IS TURNED OFF). SENSOR TO BE

MOUNTED IN PAN BELOW CLOTHES WASHER TO

SHUT VALVES OFF INCASE OF A LEAK. DEVICE

AND SENSOR TO BE LOCATED SUCH THAT THEY

CAN BE ACCESSED WITHOUT REMOVAL OF

WASHING MACHINE.

DIVISION 22

2

2

DIVISION 12

ROLLER SHADE POCKET (RSP)

(1) FURNISH AND INSTALL 6X9 ROLLER SHADE

ALUMINUM ROLLERSHADE POCKET WITH 3"

POCKET CLOSURE FLAP. BASIS-OF-DESIGN

LUTRON, NO SUBSTITIONS PERMITTED.

(2) FURNISH FULL-LENGTH, WALL TO WALL, REFER

TO DRAWINGS FOR ADDITIONAL INFORMATION.

2

2

DIVISION 10

SHOWER DOOR HINGE (SHWRHNG)

(1) FURNISH AND INSTALL, ADJUSTABLE, DOUBLE

ACTING HINGE FOR GLASS-TO-GLASS CONDITION.

FINISH TO MATCH PLUMBING FIXTURE. CONFIRM

WITH OWNER/ARCHITECT PRIOR TO ORDER.

2

COUNTERTOP RECEPTACLE (CR)

(1) FURNISH AND INSTALL 15-AMP HUBBEL

COUNTERTOP RECEPTACLE, RCT200NI IN

BRUSHED NICKEL FINISH. COUNTERBORE

COUNTERTOP FOR FLUSH INSTALLATION.

DIVISION 26 (CONT) 2

2

2

2

S4

S4

S4 S4

S4

A-601

1

6' - 0" 3' - 0" 3' - 0" 6' - 0"

4' - 4"

5' - 10" 4' - 2" 4' - 2" 3' - 9"

REF TO MECH PLAN

2' - 0" 1' - 2"

DL1 (A) DL1 (A)

DL1 (A) DL1 (A) DL1 (A)

DL2 (B) DL1 (A)

DL2 (B)

PL2D

(C2)

(A)-(C2)

TL2 (D) TL1 (D)

TL1 (E)

DL1 (E) DL1 (E)

SL1 (E)

PL3 (F)

(E)-(F)

DL3 (I)

DL4 (I)

DL4 (I)

DL4 (I)

DL4 (I)

DL4 (I)

3' - 11" 2' - 2" 2' - 4"

DL1

(G)

(G)

PL3 (H)

DL1B

(O)

DL3 (J)

DL3 (J)

DL3 (J)

SB

DL1B

(Q)

(J)

DL1B (L)

(D)

DL4(K)

(K-L)

(K-L)

2' - 0" 2' - 8" 2' - 8" 2' - 0"

REF TO MECH PLAN

PL3 (F) PL3 (F)

TL1 (E)

16' - 8" COVE

(E)-(F)

SL1

REF TO MECH PLAN

DL4(K)

REPLACE ALUM

DOOR FRAME

WHERE DAMAGED

PROVIDE AIR

TRANSFER

OPENING IN

WALL ABV

CEILING FROM

CABINET TO

PLENUM

3

A-901

3

A-901

3

A-901

(N) SOFFIT,

MATCH OPP

A-603

1

A-602

1

(N) DOOR, REF TO CALLOUT

(E) SPA

(N) SCHLUTER-TROBA-LEVEL

PEDESTAL PAVER SHIMS, TYP

ALL JOINT INTERSECTIONS

(N) PORCELAIN PAVERS

3/4" THICKNESS, 24X48

6

A-901

6

A-901

6

A-901

(N) ALUM FIN SCREEN WALL

SL1

SL1

(M)

SL1

(M)

CONVERT (E) SINGLE

HOSE BIBB TO DOUBLE

BIBB OUTLET

A-901

8

A-901

8 A-901

8

EXISTING CABINETRY,

REMOVE (E) DRAWERS AND

RETROFIT W/ (N) DRAWER

BOXES, HARDWARE AND

FACE PANELS. PROTECT (E)

COUNTERTOP

SHEET METAL CLADDING

ATTACHED TO METAL FRAME,

POWDERCOATED BLACK.

MATCH HEIGHT OF SCREEN WALL

+48"

DL4 (N)

DL4 (N)

(H/I/N)

+36"

COORD

FRAMING

AND POWER

W/ AV

CONSULT

FOR DROP

PROJECTION

SCREEN (NIC)

SPLICE POWER AT (E)

OUTLET AND RUN (N)

CONDUIT BELOW PAVERS

TO OPP SIDE FOR NEW

ELECTRICAL WORK

(N) OUTLET AT 9"

DL2 (B)

DL2 (B)

2' - 10 1/2" 2' - 11" 2' - 10 1/2" 2' - 7"

PL2A

(C1)

3' - 6" 3' - 6"

DL1

(G)

DL1

(G)

DL1

(G)

DL1

(G)

DL1

(G)

3' - 5" 4' - 6"

2

2

COORD POWER FOR

AV PROJECTOR (NIC)

+66"

SL1

SL1

X3

SL1

X2

(P)

(P)

(O-P)

SL1 (E)

2

REFER TO ENLARGED KITCHEN PLAN

FOR ADDITIONAL INFORMATION

(N) WATER SHUT-OFF VALVES W/ LEAK

DETECTION SYSTEM TECHNOLOGY

2

2' - 0"

ROLLER SHADE

POCKER, REF

ROLLER SHADE TO DETAIL

POCKER, REF

TO DETAIL 2

2

PL2C

(C1)

PL2B (C1)

NEW 2-1/2" METAL FRAMING, 6" O.C.

W/ FLEXIBLE GYPSUM BOARD,

BEND AS INDICATED

R 1' - 2"

2

A-901

8

REF TO MECH PLAN

TO CL

10' - 0"

2' - 4"

5' - 11"

(N) OUTLET AT 9"

2' - 4"

EQ EQ

DL1B

(R)

1' - 0"

1' - 0"

2' - 6" 2' - 6"

SL1 X4

(Q)

DL1B

(O)

DL1B (O)

DL1B (O)

FLOOR PLAN LEGEND

NEW WALL W/ 2X4

METAL STUD FRAMING AND

MINERAL WOOL INSULATION AND

1/2" CEMENT BOARD (WET SIDE)

PAINTED GWB (OPP)

EXISTING WALL TO REMAIN

DUPLEX RECEPTACLE OUTLET

QUADPLEX RECEPTACLE OUTLET

CASETA WIRELESS IN-WALL

DIMMER PRO, 120V

4-BUTTON PICO WIRELESS SCENE

CONTROLLER: PROGRAM W/ OWNER

PRIOR TO PROJECT CLOSE-OUT

SB CASETA SMART BRIDGE

CT

DW

EH

ICE

MW

OV

ELECTRIC INDUCTION COOKTOP

RECESS FOR FLUSH INSTALLATION

DISHWASHER - CUSTOM PANEL

RECIRCULATING EXHAUST HOOD INSERT

CUSTOM PANEL AND HOUSING

ICE MAKER

CUSTOM PANEL REQUIRES DRAIN

MICROWAVE SPEED OVEN

CONVECTION OVEN

EQUIPMENT LEGEND

REF

SNK

SNKF

SO

VS

WS

FRIDGE/FREEZER

CUSTOM PANEL

KITCHEN SINK

KITCHEN SINK FAUCET

STEAM OVEN

VACCUM SEAL DRAWER

CUSTOM PANEL

WINE STORAGE

CUSTOM PANEL

CONSTRUCTION NOTES

(1) REFINISH ENTIRE APARTMENT FLOOR

INCLUDING UNDERNEATH FURNITURE (I.E.

CABINETS AND ISLAND). SAND (E) WOOD FLOOR TO

REMOVE COLOR. REFINISH WITH CLEAR, UV-CURED

WATER-BASED ULTRA MATTE SEALER. UV-CURED

SEALER IS FIELD-APPLIED AND REQUIRES SPECIAL

EQUIPMENT. REFER TO SPECIFICATIONS FOR

ADDITIONAL INFORMATION. PERFORM A MOCK-UP

TEST FOR ARCHITECT AND OWNER REVIEW PRIOR

TO PROCEEDING WITH WORK.

(2) NEW BASEBOARD INSTALLED THROUGH ENTIRE

APARTMENT, REFER TO CONSTRUCTION DETAILS

FOR ADDITIONAL INFORMATION.

(3) PROVIDE NEW PAINT THROUGHOUT ENTIRE

APARTMENT ON ALL WALLS AND CEILINGS. SATIN

FINISH AT WALLS AND BASEBOARD AND MATTE

FINISH ON CEILING. CUSTOM COLOR TO BE

DETERMINED. PATCH AND REPAIR BATHROOM-1

CEILING FOR LEVEL 4 FINISH.

(4) PROVIDE DIMMING WIRE (NEUTRAL WIRE) FOR

ALL NEW LIGHTING.

(5) ALL LIGHTING WITHIN ROOM IS ON A SINGLE

SWITCH IF ZONING LETTER IS NOT INDICATED

(6) ROUTE ALL REMOTE DRIVERS TO AV CLOSET.

(7) RESERVED - REFER TO MECH PLAN.

(8) PROVIDE NEW WATERPROOFING AT

BATHROOMS. FURNISH AND INSTALL SCHLUTER

KERDI AT SHOWER PAN AND FULL-HEIGHT AT

WALLS AND LATICRETE 9235 AT ENTIRE FLOOR

AREA AND UPTURN 6" MINIMUM AT BASE OF WALL

WALL. LAP SCHLUTER KERDI OVER TOP OF

SHOWER CURB IN ACCORDANCE WITH

MANUFACTURER RECOMMENDATIONS.

(9) CONTRACTOR TO COORDINATE WORK WITH

OWNER'S AUDIO-VISUAL CONTRACTOR. AUDIO-

VISUAL CONTRACTOR WILL PULL THEIR OWN WIRE.

CONTRACTOR TO ASSUME MISCELLANEOUS PATCH

AND REPAIR.

(10) REFER TO ELEVATIONS FOR ADDITIONAL

REQUIREMENTS INCLUDING ELECTRICAL OUTLETS

NOT SHOWN ON PLAN.

(11) LED STRIP LIGHTING WITHIN CABINETRY AND

AT LAUNDRY CLOSET TO BE PROVIDED WITH

OCCUPANCY SENSOR SWITCH. CONTRACTOR TO

COORDINATE POWER AND WIRING REQUIREMENTS

WITH MILLWORKER. EXPOSED WIRING WILL NOT BE

PERMITTED.

(12) CONTRACTOR SHALL SUBMIT AN ELECTRICAL

LOAD LETTER TO ARCHITECT AND OWNER PRIOR

TO COMMENCEMENT OF WORK. NO ELECTRICAL

WORK PERMITTED OUTSIDE OF THE APARTMENT.

(13) INTERIOR DOOR PANELS ARE CURRENTLY

OBSERVED TO BE WARPED 1/2" OUT OF PLANE.

CONTRACTOR SHALL REMOVE ALL INTERIOR WOOD

DOOR PANELS, VERIFY STRAIGHTNESS AND

CORRECT AS NEEDED TO ACHIEVE 1/8" PLANAR

TOLERANCE. REPLACE EXISTING GLASS LITE WITH

LAMINATED PRIVACY GLASS AND PVB INTERLAYER

(GL2). SET HINGES AND HARDWARE, REMOVE, AND

FIELD-PAINT DOOR. CUSTOM COLOR TO BE

DETERMINED.

(14) ALL LIGHTING CONTROLS MOUNTED 44" TO

CENTERLINE, ABOVE FINISH FLOOR, U.N.O.

2

2

2

N

LIGHTING LEGEND

LED STRIP, COVE

MIN 3.5 W PER FT AVG 2700K 90 CRI

LUMINII OR APPROVED EQUAL

3" MINI LED RECESSED ROUND DN LIGHT (DL1)

15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-55-S-WH-NCE-UNV-D22-DEV

WHITE TRIMLESS FLANGE

8" BOLA SPHERE PENDANT (BRASS)

0-10v DIMMER OR ELV

MOUNT BOTTOM OF LIGHT 6'-0" ABV FF

OFCI

DECORATIVE WALL SCONCE

OFCI

SL1

DL1

DL3

TL1 TRACK LIGHT W/ (1) 12" ADJ MED SPOTLIGHT HEADS (TL1) LENGTH AS NOTED ON PLAN

11 WATT PER MODULE 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING CORONET MAGR-TRK-XX"-DR60-UNV-NT-BLK-DEV

CORONET MAG-SPMD-27-MED-BLK-FL-HEX-DEV

MUD-IN FLANGE W/ BLANK OFF

1" LED RECESSED ROUND DN LIGHT (DL3)

9 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI Z1RDL-09X1M-27KH-35-M0-BL-NC-RPD01-UNV-D6A-DEV WHITE COORD ACCESS FOR REMOTE DRIVER

WL1

PL1

DL4

1" LED RECESSED ROUND DN LIGHT, WALL WASHER (DL4)

9 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI Z1RWL-09X1M-27KH-W2-D1-BL-NC-RPD01-UNV-D6A-DEV WHITE COORD ACCESS FOR REMOTE DRIVER

TL2 TRACK LIGHT W/ (2) 12" ADJ MED SPOTLIGHT HEADS (TL2) LENGTH AS NOTED ON PLAN

11 WATT PER MODULE 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING CORONET MAGR-TRK-XX"-DR60-UNV-NT-BLK-DEV

CORONET MAG-SPMD-27-MED-BLK-FL-HEX-DEV

MUD-IN FLANGE W/ BLANK OFF

3" MINI LED RECESSED ROUND DN LIGHT, WALL WASHER (DL2) 15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-W2-S-WH-NCE-UNV-D22-DEV

WHITE TRIMLESS FLANGE

DL2

FOSCARINI RITUAL SERIES

CONFIRM DIMMING CAPABILITIES

MOUNTING HEIGHT VARIES FIELD-VERIFY

OFCI

PL2

ABCD

3" MINI LED RECESSED ROUND DN LIGHT (DL1)

15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-65-S-WH-NCE-UNV-D22-DEV

WHITE TRIMLESS FLANGE

DL1

PL3 LED PENDANT

OFCI

1 BID SET 6/1/22

139 FULTON STREET #810 NY, NY 10038

******@*****************.***

ANDREARCHITECTURE.COM

(PH) 917-***-****

ARCHITECT

ANDRE ARCHITECTURE DPC

© 2021 ANDRE ARCHITECTURE

111 FULTON STREET PH110

NEW YORK, NY 10003

PROJECT

APT RENOVATION

2 2ND BOARD SUBMITTAL 7/29/22

# ISSUE DESCRIPTION DATE

3 FOR CLIENT REVIEW 8/28/22

4 FINAL BID SET 9/29/22

A-101

ARCHITECTURAL

PLAN

1/4" = 1'-0"

1

ARCHITECTURAL PLAN

CLR

4' - 5 1/4"

7' - 3"

FULL-WIDTH

SHOWER NICHE, T1

ST1

GLASS

MOUNTED

TOWEL BAR,

OFCI

2' - 6"

4" (H) CURB

ST1 CLAD ALL SIDES

UNDERMOUNT

SINK, OFCI

TUB

MATCH

2 A-601 5

3

A-601

4

1' - 2"

4-1/2" CLR

6

PROVIDE

POWER OUTLET

IN BOTOM

DRAWER OF

BASE CABINET

60X24

60X48

NUHEAT STANDARD ELECTRIC HEATING

MAT 120V W/ PROGRAMMABLE

THERMOSTAT AND WIFI-ENABLED,

STANDARD SIZES AS INDICATED

ST1

PONY WALL - ST1

CLAD ALL SIDES

T3

(E) DRAIN TO

REMAIN IN

PLACE

SAWCUT SURFACE

TREATMENT FOR

SLIP RESISTANCE

SHWRHNG

1' - 2"

CUSTOM

VANITY

MIRROR

115

CLR

3' - 6"

(E) TUB

9"

3' - 0 1/4" 4 1/4"

EQ EQ EQ

LED TAPE LIGHT AND

POWER RECEPTACLES

FOR LIGHTING DRIVER

LED TAPE LIGHT AND

POWER RECEPTACLES

FIXED MIRRORED GLASS

W/ CUSTOM LIGHT BOX

INTEGRAL GROOVED

EDGE PULL

7' - 3"

1"

7' - 1" 3' - 2 3/4"

T1

3' - 8" 3' - 0"

CUSTOM MILLWORK

EXT - WD1

INT - PL1

IN-DRAWER POWER RECEPTACLES

MIN 4-OUTLETS.

NO EXPOSED WIRING PERMITTED.

CUSTOM MIRROR CABINET

4 INT - PL1

A-604

LED TAPE LIGHT

5

A-604

2

REF TO DETAIL CALLOUTS

FOR ADDITIONAL POWER

REQUIREMENTS

WALL MOUNTED FAUCET,

OFCI

6' - 4"

GAP FILLER, 1" REVEAL

W/ MIRROR FINISH

1"

1' - 3"

8

A-902

2 1/4"

T1

3' - 8" 3' - 0" 3' - 2"

4' - 0" 1' - 9"

GL1

ST1

GLASS SWING

DOOR, GL1

(E) TUB

2' - 4"

8' - 0"

GLASS MOUNTED TOWEL BAR

OFCI

3' - 9"

PAINTED GWB

2' - 4"

EQ EQ

GLASS SWING DOOR

GL1

GL1

T1

ST1

GLASS MOUNTED DOOR HANDLE

OFCI

4' - 0"

3' - 8"

CHROME TILE TRIM

2' - 1" 1' - 9"

3' - 8" 3' - 0" 3' - 2"

T1

SHOWERHEAD

OFCI

SHOWER COLUMN W/ HAND WAND

OFCI

DIVERTER VALVE

OFCI

SHOWER CONTROLS

OFCI

4' - 0"

3' - 8"

T1

PAINTED GWB

LIGHTING CONTROLS

PC1

BATH

CONTROLS

OFCI

CHROME

TILE TRIM CHROME TILE TRIM

CONSTRUCTION NOTES

(1) ALL FIXTURES AND APPLIANCES ARE OWNER

FURNISHED, CONTRACTOR INSTALLED.

CONTRACTOR SHALL COORDINATE

MANUFACTURER REQUIREMENTS FOR COMPLETE

INSTALLATION INCLUDING POWER, WATER, AND

DRAINAGE. CONTRACTOR SHALL FURNISH AND

INSTALL CUSTOM