PROJECT
APT RENOVATION
2 2ND BOARD SUBMITTAL 7/29/22
# ISSUE DESCRIPTION DATE
3 FOR CLIENT REVIEW 8/28/22
4 FINAL BID SET 9/29/22
A-000
GENERAL SHEET
PROJECT INFORMATION
DRAWINGS INDEX
GENERAL
A-000 - GENERAL SHEET
A-001 - SPECIFICATIONS
DEMOLITION
D-101 - DEMO PLAN
ARCHITECTURAL
A-101 - ARCHITECTURAL PLAN
A-601 - ENLARGED BATH-1
A-602 - ENLARGED BATH-2
A-603 - ENLARGED KITCHEN
A-604 - MISC MILLWORK
A-901 - CONSTRUCTION DETAILS
A-902 - CONSTRUCTION DETAILS
MECHANICAL
M-101 - MECHANICAL PLAN
PLUMBING PLAN
P-101 - PLUMBING PLAN
(D) - DEPTH / DEEP
(E) - EXISTING
(H) - HEIGHT / HIGH
(L) - LENGTH / LONG / WIDE
(N) - NEW
AFF - ABOVE FINISHED FLOOR
B.O. - BOTTOM OF
CL - CENTERLINE
CLG - CEILING
CLR - CLEAR (FINISH TO FINISH)
DBL - DOUBLE
DR - DOOR
DHW - DOMESTIC HOT WATER
DN - DOWN
FF - FINISH FLOOR
FPSC - FIRE PROTECTED W/ SELF CLOSER
F.O. - FACE OF
F.O.F. - FACE OF FINISH
FR - FIRE RATED
GWB - GYPSUM WALL BOARD
HDR - HEADER
IGU - INSULATED GLASS UNIT
LT - LIGHT
MTL - METAL
OC - ON CENTER
OFCI - OWNER FURNISH / CONTRACTOR INSTALL
OPP - OPPOSITE
PT - PRESSURE TREATED
SIM - SIMILAR
SS - STAINLESS STEEL
SW - STORMWATER
T.O. - TOP OF
UNO - UNLESS NOTED OTHERWISE
VIF - VERIFY IN FIELD
W/ - WITH
ABBREVIATIONS
PROJECT ADDRESS
111 FULTON ST PH110
NEW YORK, NY 10038
SCOPE OF WORK
INTERIOR RENOVATION OF PRIVATE
APARTMENT AND MISCELLANEOUS EXTERIOR
WORK ON PRIVATE TERRACE.
(1) WORK SHALL BE COMPLETED IN
ACCORDANCE WITH THE FOLLOWING CODES OR
THE MOST UPDATED VERSION IN ADDITION TO
ALL CODES, RULES REGULATIONS, OF NEW YORK
CITY, NEW YORK STATE, AND ADA CODE:
2014 NYC MUNICIPAL BUILDING CODE
2014 NYC MECHANICAL CODE
2014 NYC PLUMBING CODE
2011 NYC ELECTRICAL CODE
2014 NYC FIRE CODE
ANSI 117.5 2007 ACCESSIBILITY CODE
(2) THESE DRAWINGS INDICATE THE GENERAL
SCOPE OF THE PROJECT, BUT DO NOT
NECESSAIRLY INDICATE OR DESCRIBE ALL ITEMS
REQUIRED FOR FULL PERFORMANCE AND
COMPLETION OF THE WORK. ITEMS NOT SHOWN
OR SPECIFIED, BUT NECESSARY FOR PROPERY
CONSTRUCTION OF ANY PART OF THE WORK,
SHALL BE INCLUDED AS IF THEY WERE
INDICATED ON THE DRAWINGS.
(3) CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING ALL DIMENSIONS AND EXISTING
CONDITIONS BEFORE STARTING WORK. REPORT
ANY DISCREPANCIES TO THE ARCHITECT.
CONTRACTOR SHALL NOT MAKE MODIFICATIONS
TO THE DESIGN TO ACCOMODATE FIELD
CONDITIONS, OR FOR ANY OTHER REASON
WITHOUT CONSULTING THE ARCHITECT.
CONTRACTOR SHALL NOTIFY ARCHITECT OF
EXISTING FIELD CONDITIONS DISCOVERED THAT
DIFFER THAN THEN THE REQUIREMENTS HEREIN.
(4) IT IS THE CONTRACTOR'S RESPONSIBILITY TO
ENSURE THAT EVERY ASPECT OF THE
CONSTRUCTION IS PERFORMED IN STRICT
CONFORMANCE WITH THE PLANS,
SPECIFICATIONS, AND CODE REQUIREMENTS.
ANY NON-COMPLIANT WORK SHALL BE REMOVED
AND REPLACED AT THE CONTRACTOR'S OWN
COST.
(5) CONTRACTOR SHALL BE RESPONSIBLE FOR
THE PROTECTION OF ALL EXISTING AND NEW
BUILDING COMPONENTS, FINISHES, AND
MATERIALS WITHIN THE CONSTRUCTION AREA.
DAMAGE WILL BE REPAIRED OR REPLACED TO
THE SATISFACTION OF THE OWNER AT THE
CONTRACTOR'S COST.
(6) CONTRACTOR SHALL BE RESPONSIBLE FOR
OBTAINING ALL PERMITS AND INSPECTIONS FOR
CONSTRUCTION, INCLUDING BUT NOT LIMITED TO
BUILDING/DEMOLITION, FIRE, PLUMBING,
SPRINKLER, MECHANICAL, AND ELECTRICAL
PERMITS. CONTRACTOR TO PAY FOR ALL
APPLICABLE FEES. CONTRACTOR TO OBTAIN
SIGN-OFFS FROM THE AUTHORITIES HAVING
JURISDICTION AS REQUIRED BY CODE.
(7) CONTRACTOR SHALL CONFIRM THAT
BUILDING OPENING CLEARANCES ARE
SUFFICIENT FOR DELIVERY AND INSTALLATION
OF WORK.
(8) CONTRACTOR SHALL HAVE SOLE
RESPONSIBILITY FOR ANY DAMAGE OR INJURIES
CAUSED BY OR DURING THE EXECUTION OF THE
WORK. SAFETY, MEANS, AND METHODS IS THE
SOLE RESPONSIBILITY OF THE CONTRACTOR.
(9) CONTRACTOR TO PROTECT ALL PUBLIC
SPACES DURING CONSTRUCTION AND
DEMOLTION WHEN DELIVERING MATERIALS AND
EQUIPMENT AND REMOVING REFUSE, RUBBISH,
AND REQUIPMENT.
(10) THE CONSTRUCTION AREA PREMISES MUST
BE MAINTAINED IN A NEAT AND ORDERLY
CONDITION AND BE KEPT FREE FROM
ACCUMULATION OF DUST AND DEBRIS DURING
THE ENTIRE CONSTRUCTION PERIOD.
GENERAL NOTES
(11) CONTRACTOR SHALL COORDINATE AND
CONFIRM CLEARANCE REQUIREMENTS FOR
INSTALLATION OF ALL TRADES AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT PRIOR TO
COMMENCING WORK.
(12) RESERVED
(13) CONTRACTOR SHALL RETAIN, COMPILE, AND
ISSUE ALL MANUALS, WARRANTIES, AND SERIAL
NUMBERS TO THE OWNER.
(14) CONTRACTOR SHALL INQUIRE WITH
BUILDING SUPERVISOR OR PROPERTY MANAGER
REGARDING CONSTRUCTION CONDITIONS,
BUILDING RULES AND REGULATIONS PRIOR TO
COMMENCEMENT OF WORK. CONTRACTOR
SHALL INQUIRE WITH SUPERINTENDENT FOR
REVIEW PRIOR TO COMMENCEMENT OF
CONCEALING WORK.
(15) CONTRACTOR TO ADHERE TO ALL CITY AND
STATE GUIDELINES FOR WORKING UNDER COVID
RESTRICTIONS.
(16) CONTRACTOR SHALL PROHIBIT THE USE OF
AIRBONE ODOR AND FUME EMITTING
CHEMICALS. FINISHING PRODUCTS MUST MEET
STATE VOC REGULATIONS AND STANDARDS.
BID REQUIREMENTS
(1) ONLY THE FOLLOWING MATERIALS ARE
OWNER-FURNISHED, CONTRACTOR-INSTALLED
AND ARE NOT TO BE INCLUDED IN THE BID:
(A) WALL AND FLOOR TILE
(B) SOLID STONE / QUARTZ SLAB MATERIAL
(C) EXTERIOR FINISH PAVERS
(D) INTERIOR LIGHTING AND IN-CABINET LIGHTING
(E) PLUMBING FIXTURES
(F) BATHROOM ACCESSORIES
(G) KITCHEN APPLIANCES
THE CONTRACTOR'S BID AMOUNT SHALL
INCLUDE THE INSTALLATION COST FOR THESE
MATERIALS IN ACCORDANCE WITH THE
DRAWINGS AND SPECIFICATIONS. THE
CONTRACTOR'S BID AMOUNT SHALL INCLUDE ALL
GENERAL PROJECT EXPENSES SUCH AS
OVERHEAD AND PROFIT. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR COORDINATING
AND RECEIVING THE OFCI MATERIALS. THE
CONTRACTOR'S BID SHALL INCLUDE
MISCELLANEOUS MATERIALS AND LABOR
REQUIRED FOR A COMPLETE INSTALLATION:
ITEMS SUCH AS ADHESIVES, GASKETS, WIRING,
SUBSTRATES, FASTENERS, GROUT, AND
MANUFACTURER RECOMMENDED FINISH
COATINGS ARE TO BE INCLUDED.
(2) THE CONTRACTOR'S BID SHALL PROVIDE
ITEMIZED AMOUNTS FOR THE FOLLOWING SCOPE
OF WORK, INCLUSIVE OF PROFIT AND OVERHEAD:
(A) EXTERIOR ALUMINUM SCREEN WALL
(B) SPA PLATFORM AND STAIRS
(C) MILLWORK CABINETRY AND WOOD PANELING
(D) MECHANICAL DUCTWORK AND DIFFUSERS
(3) CONTRACTOR'S BID SHALL INCLUDE ITEMIZED
PRICING FOR ADD-ALTERNATE #1 AND #2 AND
DEDUCT-ALTERNATE #1. REFER TO SKETCHES
FOR ADDITIONAL INFORMATION.
ILLUSTRATIVE IMAGE OF KITCHEN FOR REFERENCE ONLY - DO NOT BID OR BUILD THIS IMAGE ILLUSTRATIVE IMAGE OF BATH-1 FOR REFERENCE ONLY - DO NOT BID OR BUILD THIS IMAGE ISSUE TITLE
FINAL BID SET SEPTEMBER 29TH, 2022
PERMIT REQUIREMENTS
CONTRACTOR SHALL BE RESPONSIBLE FOR
FILING FOR AN ELECTRICAL WORK PERMIT
AND A LIMITED ALTERATION APPLICATION FOR
PLUMBING WORK WITH THE NYC DEPARTMENT
OF BUILDINGS.
2
2
2
2
1 BID SET 6/1/22
139 FULTON STREET #810 NY, NY 10038
******@*****************.***
ANDREARCHITECTURE.COM
(PH) 917-***-****
ARCHITECT
ANDRE ARCHITECTURE DPC
© 2021 ANDRE ARCHITECTURE
111 FULTON STREET PH110
NEW YORK, NY 10003
PROJECT
APT RENOVATION
2 2ND BOARD SUBMITTAL 7/29/22
# ISSUE DESCRIPTION DATE
3 FOR CLIENT REVIEW 8/28/22
4 FINAL BID SET 9/29/22
A-001
SPECIFICATIONS
DIVISION 8
GLAZING
(1) ALL INTERIOR GLAZING TEMPERED OR
LAMINATED. REFER TO DRAWINGS.
DIVISION 7
DRYWALL
(1) ALL NEW DRYWALL TYPE (X) 5/8" THICK. USE
5/8" FIRE RATED WHERE NOTED ON DRAWINGS.
USE 5/8" MOISTURE RESISTANT DRYWALL IN
BATHROOMS AND LAUNDRY ROOM.
(2) USG LEVEL 4 FINISH THROUGHOUT.
(3) OUTSIDE CORNERS SHALL HAVE METAL
CORNER BEADS. METAL CASING BEADS SHALL BE
INSTALLED WHERE DRYWALL ADJOINS OTHER
MATERIALS AND JOINT IS NOT CASED.
(4) DO NOT ATTACH GYPSUM WALL BOARD TO TOP
TRACK OF METAL FRAMING, ONLY TO VERTICAL
STUDS
FLEXIBLE GYPSUM BOARD (FGB)
(1) FURNISH AND INSTALL FLEXIBLE GYPSUM
BOARD WHERE NOTED ON DRAWINGS. BASIS-OF-
DESIGN GOLD BOND HIGH FLEX GYPSUM BOARD,
1/4" THICKNESS. INSTALL ACCORDING TO
MANUFACTURER'S INSTRUCTION TO ACHIEVE
BENDING RADIUS AS INDICATED ON DRAWINGS.
WETTING MAY BE REQUIRED.
PAINTING
(1) ALL PAINTING TO CONTAIN ZERO VOLATILE
ORGANIC COMPOUNDS (VOC). NO INTERIOR OIL-
BASED PAINT WILL BE PERMITTED.
WOOD FLOOR FINISH (WDFF)
(1) FURNISH AND INSTALL UV-CURED
WATERBORNE FINISH, PROCOAT, RADCOAT IN
ULTRAMATTE SHEEN IN ACCORDANCE WITH
MANUFACTURER REQUIREMENTS AND WRITTEN
INSTRUCTIONS. SUBSTITUTIONS NOT PERMITTED.
(2) THIS PRODUCT REQUIRES UV CURING
EQUIPMENT, SPECIAL EQUIPMENT MUST BE
PROVIDED BY CONTRACTOR. A KNOWN LOCAL
SUBCONTRACTOR WITH SPECIALITY EQUIPMENT
AND APPLICABLE EXPERIENCE IS LISTED BELOW.
(3) PREFERRED CONTACT FOR LOCAL INSTALLER:
BRIAN PRUSIK, RETAILER FLOORING SOLUTIONS,
CELL NUMBER IS 315-***-****. EMAIL ADDRESS IS
*****@**********.***
TILE FINISH TRIM (TFT)
(1) FURNISH AND INSTALL TILE EDGE TRIM WHERE
INDICATED ON DRAWINGS. BASIS-OF-DESIGN
SCHLUTER-SCHIENE, FINISH AS NOTED ON
DRAWINGS. NO PRODUCT SUBSITUTIONS
PERMITTED.
(2) FINISH EDGE FLUSH TO TILE, CONTRACTOR TO
COORDINATE PROFILE HEIGHT REQUIREMENTS.
DIVISION 6
INTERIOR TRIM AND CARPENTRY
(1) ALL MATERIAL DOUGLAS FIR OR MDF, NON
FINGER JOINTED, UNLESS NOTED OTHERWISE. NO
SPLICES ALLOWED ON RUNS LESS THAN
FOURTEEN FEET (14') IN LENGTH.
CUSTOM MILLWORK
(1) CUSTOM MILLWORK INCLUDES CABINETRY,
SHELVING, BUILT-IN FURNITURE, AND SIMILAR
WOODWORK ITEMS NOT INDICATED AS NIC OR
OWNER-FURNISHED. ALL MATERIALS AND FINISHES
TO BE PROVIDED AS NOTED ON PLANS. ALL
MATERIALS AND FINISHES TO BE SEALED AND
FINISHED ON ALL SIDES. ALL NAILS, SCREWS,
GLUE, OR ANY OTHER MEANS OF ASSEMBLING THE
CABINETRY NOT TO BE VISIBLE. ALL MILLWORK
FORMALDEHYDE FREE.
(2) 1/8" MAX BUTT JOINT TYPICAL. END SHIMS,
SPACERS, AND GAPS NOT TO EXCEED 1/4".
(3) ALL CABINETRY TO BE PLYWOOD, FRAMLESS
BOX CONSTRUCTION. FINISH EXPOSED EDGES OF
PLYWOOD BOX TO MATCH INTERIOR.
(4) DRAWER FRONTS AND DOOR FRONTS TO BE
MINIMUM 3/4" THICK, FINISH TO MATCH EXTERIOR
ON ALL SIDES.
(5) ALL DRAWER BOXES TO BE MINIMUM 3/4" THICK
PLYWOOD WITH EASED EDGES AND CORNERS,
DOVETAIL CONSTRUCTION. FURNISH BLUMOTION,
SELF-CLOSING, UNDERMOUNT DRAWER GLIDES.
(6) ALL DOOR FRONTS TO BE FURNISHED WITH
INSET EUROPEAN STYLE HINGES, SOFT-CLOSE.
(7) WHERE SHOP APPLIED LACQUER IS NOTED ON
DRAWINGS, FINISH TOP COAT TO BE SOLVENT-
BASED PRE CATALYZED LACQUER, CATALYZED
LACQUER, OR CONVERSION VARNISH. FINISH TO BE
APPLIED AFTER DOORS HINGES AND HARWARE
HAS BEEN SET. NO RAW WOOD LEFT UNFINISHED.
(8) PROVIDE SHOP DRAWINGS, PRODUCT AND
MANUFACTURER CUT SHEETS, AND SAMPLES OF
EXPOSED METALS INCLUDING HARDWARE.
COMPOSITE DECK (TREX)
(1) FURNISH AND INSTALL COMPOSITE DECKING
WHERE NOTED ON DRAWINGS. BASIS-OF-DESIGN,
TREX SELECT - WINCHESTER GREY. PROFILE IS A
COMBINATION OF SQUARE AND GROOVED WITH
CONCEALED FASTERNERS, REFER TO DRAWINGS.
WHERE FASTENERS OCCUR, PROVIDE OIL-RUBBED
STAINLESS STEEL OR SIMILAR.
(2) ALUMINUM FRAMED SUPPORT SPACING NOT TO
EXCEED 16" ON CENTER, WITH THERMOPLASTIC
SHIMS WHEREVER FRAME IS IN CONTACT WITH
GROUND SURFACE.
(3) THIS SPECIALITY CUSTOM FURNITURE MUST BE
MADE REMOVABLE WITHOUT THE USE OF SPECIAL
TOOLS AND EQUIPMENT, CONFIRM DESIGN INTENT
WITH ARCHITECT AND OWNER PRIOR TO
COMMENCEMENT OF WORK.
DIVISION 1
RESERVED
(1) RESERVED
DIVISION 9
DIVISION 2
DIVISION 3
DIVISION 4
DIVISION 5
RESERVED
(1) RESERVED
RESERVED
(1) RESERVED
RESERVED
(1) RESERVED
METAL FRAMING (NON-BEARING)
(1) ALL METAL FRAMING TO BE TRUE, LEVEL,
AND PLUMB. INSTALL FRAMING MEMBERS
PLUMB WITHIN 1/4" IN 10'. INSTALL EACH
FRAMING MEMBER SO FASTENING SURACES
DO NOT VARY MORE THAN 1/8".
(2) DESIGN LOADS: 5 PSF MINIMUM OR AS
REQUIRED BY THE INTERNATIONAL BUILDING
CODE. DESIGN FRAMING SYSTEM TO
ACCOMODATE DEFLECTION OF PRIMARY
BUILDING STRUCTURE AND CONSTRUCTION
TOLERANCES.
(3) PROVIDE SLIP-TYPE HEAD JOINTS:
SINGLE LONG-LEG RUNNER SYSTEM, TOP
RUNNER WITH 2" DEEP FLANGES IN
THICKNESS NOT LESS THAN INDICATED FOR
STUDS, INSTALLED WITH THE STUDS FRICTION
FIT INTO TOP RUNNER AND WITH
CONTINUOUS BRIDGING LOCATED WITHIN 12
INCHES OF THE TOP OF STUDS TO PROVIDE
LATERAL BRACING.
DEFLECTION TRACK, STEEL SHEET TOP
RUNNER MANUFACTUED TO PREVENT
CRACKING OF FINISHES APPLIED TO INTERIOR
PARTITION FRAMING RESULTING FROM
DEFLECTION OF STRUCTURE ABOVE; IN
THICKNESS NOT LESS THAN INDICATED FOR
STUDS AND IN WIDTH TO ACCOMODATE
DEPTH OF STUDS.
(4) BRIDIGING MEMBERS NOT LESS THAN .054"
THICK WITH MINIMUM FLANGE NOT LESS THAN
1/2" WIDE. CLIP ANGLES NOT LESS THAN 1-1/2"
X 1-1/2".
(5) PROVIDE ISOLATION STRIPS WHERE METAL
FRAMING IS IN CONTACT WITH EXTERIOR
WALLS.
(6) FOR DOOR FRAMING SECURELY FASTERN
VERTICAL STUDS AT JAMBS TO JAMB ANCHOR
CLIPS ON DOOR FRAMES; INSTALL RUNNER
TRACK SECTION (FOR CRIPPLE STUDS) AT
HEAD AND SECURE TO JAMB STUDS. INSTALL
TWO STUDS AT EACH JAMB. EXTEND JAMB
STUDS TO UNDERSIDE OF OVERHEAD
STRUCTURE.
(7) DO NOT BRIDGE BUILDING CONTROL AND
EXPANSION JOINTS.
SMOKE/CARBON MONOXIDE DETECTORS
(1) SMOKE/CARBON MONOXIDE DETECTORS OR
DEVICES SHALL BE INSTALLED IN ORDINANCE
WITH THE HOUSING MAINTENANCE CODE,
MULTIPLE DWELLING LAW, THE NEW YORK CITY
BUILDING CODE, THE NEW YORK CITY
ELECTRICAL CODE AND THE NFPA 72.
(2) SMOKE DETECTORS AND CARBON MONOXIDE
DETECTORS MAY BE COMBINED PROVIDING THE
DEVICES COMPLY WITH THE PROVISIONS OF
TITLE 28 OF THE ADMINISTRATIVE CODE OF THE
CITY OF NEW YORK AND ANY APPLICABLE RULES
PROMULGATED THEREUNDER.
(3) EACH SMOKE/CARBON MONOXIDE DETECTOR
SHALL BE INSTALLED IN ACCORDANCE WITH
REFERENCE STANDARD UL 2034 AND UL 2075 OF
THE NEW YORK CITY BUILDING CODE.
(4) EACH SMOKE/CARBON MONOXIDE DETECTOR
SHALL BE INSTALLED OUTSIDE OF EACH
SLEEPING ROOM IN THE IMMEDIATE VICINITY OR
WITHIN 15'-0" OF THE ENTRANCE TO A SLEEPING
ROOM; INSIDE EACH SLEEPING ROOM; AND ON
EACH STORY WITHIN A DWELLING UNIT,
INCLUDING BELOW GRADE STORIES AND
PENTHOUSES AS PER 908.7.1.1.1
(5) EACH SMOKE/CARBON MONOXIDE DETECTOR
SHALL BE OF A TYPE THAT ALLOWS FOR READILY
TESTING OF SUCH DEVICE.
(6) DUPLEX UNITS SHALL HAVE A DEVICE
LOCATED ON EACH LEVEL IF ONLY ONE MEANS
OF EGRESS IS PROVIDED FOR EACH LEVEL.
(7) CEILING MOUNTED DEVICES SHALL BE A
MINIMUM DISTANCE OF 4" FROM ANY WALL. WALL
MOUNTED DEVICES SHALL BE A MINIMUM OF 4"
TO A MAXIMUM OF 12" FROM THE CEILING.
(8) EACH DWELLING UNIT SHALL BE EQUIPPED
WITH AN APPROVED TYPE SMOKE/CARBON
MONOXIDE DETECTOR DEVICE RECEIVING
PRIMARY POWER FROM THE BUILDING WIRING
WITH NO SWITCHES IN THE CIRCUIT OTHER THAN
THE OVER CURRENT DEVICE PROTECTING THE
BRANCH CIRCUIT AS PER NEW YORK CITY
BUILDING CODE SEC. 907.2.10.2 THROUGH
907.2.10.4
(9) EXISITNG BUILDINGS THAT ARE NOT
EQUIPPED WITH HARDWIRED CONENCTIONS
SHALL BE SUPPLIED WITH BATTERY OPERATED
DEVICES.
(10) SUCH SMOKE/CARBON MONOXIDE
DETECTOR MUST BE EITHER THE IONIZATION
CHAMBER TYPE OR THE PHOTOELECTRIC
DETECTOR TYPE AS PER NEW YORK CITY
BUILDING CODE SECTION 907 AND 908.
(11) A "CERTIFICATE OF SATISFACTORY
INSTALLATION FOR SMOKE/CARBON MONOXIDE
DETECTORS" MUST BE FILED WITH THE DIVISION
OF CODE ENFORCEMENT HPD 10 DAYS AFTER
INSTALLATION.
(12) WRITTEN INFORMATION OF TESTING AND
MAINTENANCE OF THE DEVICES SHALL BE
PROVIDED TO THE DWELLING UNIT OWNER.
(13) IN MULTIPLE DWELLINGS (R-2) SMOKE
ALARMS SHALL BE ABLE TO SUPPORT VISIBLE
ALARM PER ANSI A117.1
DIVISION 28
MINERAL WOOL INSULATION
(1) PROVIDE MINERAL STONE WOOL INSULATION
AT ALL NEW INTERIOR WALLS. FILL ENTIRE
CAVITY BETWEEN STUDS, NO GAPS PERMITTED.
(2) FURNISH ROCKWOOL OR THERMAFIBER
PEDESTAL PAVER SYSTEM (PPS)
(1) PROVIDE SHIM AND LEVEL SYSTEM WHERE
NEW PAVERS OCCUR, REF TO DRAWINGS.
BASIS-OF-DESIGN, SCHLUTER TROBA-LEVEL LV3
AND PL 10 WITH 1/8" TAB SPACING. SYSTEM
MUST BE RATED FOR AT LEAST 1000 LBS.
PRODUCT SUBSTITUTIONS ARE ACCEPTABLE
WITH ARCHITECT APPROVAL.
(3) HEIGHT INSTALLATION WILL VARY BUT IS
APPROXIMATELY 7/8", REFER TO DRAWINGS
FOR ADDITIONAL INFORMATION.
(4) PROVIDE COMPLETE SYSTEM INCLUDING
TABS, LEVELERS, AND SHIMS AS NEEDED FOR
COMPLETE LEVEL AND FLUSH INSTALLATION.
BONDED WATERPROOFING MEMBRANE (WP1)
(1) INSTALL SCHLUTER KERDI BONDED
WATERPROOFING SYSTEM PER MANUFACTER
REQUIREMENTS. FURNISH ALL INSTALLATION
AND TRANSITION DETAILS FOR COMPLETE
SYSTEM.
(2) INSTALL AT SHOWER FLOOR AND FULL-
HEIGHT AT SHOWER WALLS.
(3) PROVIDE A 24 HOUR FLOOD TEST AT
SHOWER PAN BEFORE SETTING TILE TO
DETERMINE WATERTIGHTNESS. DOCUMENT
WITH PHOTOS AND WRITTEN REPORT.
LIQUID WATERPROOFING MEMBRANE (WP2)
(1) FURNISH AND INSTALL LATICRETE 9235
WATERPROOFING MEMBRANE PER
MANUFACTURER REQUIREMENTS.
(2) INSTALL AT BATHROOM FLOOR AND UP 4"
MIN AT PERIMETER WALLS AND SHOWER CURB.
LIGHTING
(1) NOT LESS THAN 90 PERCENT OF THE
PERMANENTLY INSTALLED LIGHTING FIXTURES
SHALL USE LAMPS WITH AN EFFICACY OF AT
LEAST 65 LUMENS PER WATT, OR HAVE A TOTAL
LUMINAIRE EFFICACY OF AT LEAST 45 LUMENS
PER WATT.
DIVISION 26
2
PLUMBING
1) ALL COLD & HOT WATER SUPPLY PIPING
SHALL BE COPPER TUBING, TYPE "L" PER ASTM
B88 WITH WROUGHT COPPER FITTING PER ANSI
B16.22 JOINED WITH SOLDER CONFORMING TO
ASTM B32 (95% TIN/ 5% ANTIMONY)
(2) ALL SANITARY DRAINAGE AND VENT PIPING
SHALL BE NO HUB CAST IRON SOIL PIPE PER
ANSI 112-5-71.
(3) ALL POTABLE PIPING SHALL BE INSULATED
WITH OWENS CORNING FIBERGLASS PIPE
INSULATION ASJ/SSL-11. INSULATION THICKNESS
SHALL BE 1" FOR PIPE SIZES 2" AND SMALLER
AND SHALL BE 1-1/2" THICK FOR PIPE SIZES 2-1/2"
THROUGH 4". ALL PIPING, FITTINGS, VALVES, ETC.
SHALL BE PROPERLY INSULATED TO PREVENT
SWEATING AND/OR HEAT LOSS.
(4) CHANGES IN DIRECTION IN DRAINAGE PIPING
SHALL BE MADE WITH THE APPROPRIATE USE OF
45 DEGREE WYES, LONG SWEEPS, SHORT
SWEEPS, SIXTH, QUARTER, EIGHTH OR
SIXTEENTH BENDS, OR BY A COMBINATION OF
THESE OR EQUIVALENT FITTINGS.
(5) SANITARY TEES AND QUARTER BENDS MAY
BE USED IN DRAINAGE LINES ONLY WHERE THE
DIRECTION OF FLOW IS FROM THE HORIZONTAL
TO THE VERTICAL.
(6) SHORT SWEEPS WILL BE PERMITTED IN
DRAINAGE PIPING 3 INCHES DIAMETER OR
LARGER FOR ANY OFFSETS EITHER HORIZONTAL
OR VERTICAL.
(7) ALL PIPING SHALL BE PROPERLY AND
SECURELY FASTENED AND/OR HUNG SO AS NOT
TO COME IN CONTACT WITH NOR BE SUPPORTED
BY ANYTHING OTHER THAN THE PROPER AND
INTENDED SUPPORTS MENTIONED.
(8) ALL WASTE LINES SHALL BE PROPERLY
PITCHED MINIMUM 1/4" PER FOOT AND PIPED TO
INSURE TOTAL DRAINAGE AND SO AS NOT TO
CREATE NOR FORM TRAPS.
(9) NO SUPPLY WATER LINES SHALL USE
FLEXIBLE OR BENDABLE FITTINGS.
(10) PROVIDE ANTI-SCALD VALVES FOR TUB &
SHOWERS. VERIFY & COORDINATE WITH
ARCHITECT'S FIXTURE SELECTION PRIOR TO
ORDER, PURCHASE & INSTALLATION OR
TUB/SHOWER MIXING VALVES.
(11) ALL DOMESTIC WATER LINES LOCATED IN
NON-HEATED AREAS ARE TO BE HEAT TRACED &
INSULATED TO AVOID FREEZING (ATTICS,
CRAWLSPACES, EXTERIOR WALL, ETC.)
LEAK DETECTION SYSTEM (LDS)
(1) WATTS INTELLIFLOW SERIES A2C-M1
AUTOMATIC WASHING MACHINE WATER SHUTOFF
VALVE WITH LEAK SENSOR. AUTOMATIC VALVES
OPEN WHEN ELECTRICAL CURRENT IS DETECTED
AND CLOSE WHEN NO CURRENT IS DETECTED
(THE MACHINE IS TURNED OFF). SENSOR TO BE
MOUNTED IN PAN BELOW CLOTHES WASHER TO
SHUT VALVES OFF INCASE OF A LEAK. DEVICE
AND SENSOR TO BE LOCATED SUCH THAT THEY
CAN BE ACCESSED WITHOUT REMOVAL OF
WASHING MACHINE.
DIVISION 22
2
2
DIVISION 12
ROLLER SHADE POCKET (RSP)
(1) FURNISH AND INSTALL 6X9 ROLLER SHADE
ALUMINUM ROLLERSHADE POCKET WITH 3"
POCKET CLOSURE FLAP. BASIS-OF-DESIGN
LUTRON, NO SUBSTITIONS PERMITTED.
(2) FURNISH FULL-LENGTH, WALL TO WALL, REFER
TO DRAWINGS FOR ADDITIONAL INFORMATION.
2
2
DIVISION 10
SHOWER DOOR HINGE (SHWRHNG)
(1) FURNISH AND INSTALL, ADJUSTABLE, DOUBLE
ACTING HINGE FOR GLASS-TO-GLASS CONDITION.
FINISH TO MATCH PLUMBING FIXTURE. CONFIRM
WITH OWNER/ARCHITECT PRIOR TO ORDER.
2
COUNTERTOP RECEPTACLE (CR)
(1) FURNISH AND INSTALL 15-AMP HUBBEL
COUNTERTOP RECEPTACLE, RCT200NI IN
BRUSHED NICKEL FINISH. COUNTERBORE
COUNTERTOP FOR FLUSH INSTALLATION.
DIVISION 26 (CONT) 2
2
2
2
S4
S4
S4 S4
S4
A-601
1
6' - 0" 3' - 0" 3' - 0" 6' - 0"
4' - 4"
5' - 10" 4' - 2" 4' - 2" 3' - 9"
REF TO MECH PLAN
2' - 0" 1' - 2"
DL1 (A) DL1 (A)
DL1 (A) DL1 (A) DL1 (A)
DL2 (B) DL1 (A)
DL2 (B)
PL2D
(C2)
(A)-(C2)
TL2 (D) TL1 (D)
TL1 (E)
DL1 (E) DL1 (E)
SL1 (E)
PL3 (F)
(E)-(F)
DL3 (I)
DL4 (I)
DL4 (I)
DL4 (I)
DL4 (I)
DL4 (I)
3' - 11" 2' - 2" 2' - 4"
DL1
(G)
(G)
PL3 (H)
DL1B
(O)
DL3 (J)
DL3 (J)
DL3 (J)
SB
DL1B
(Q)
(J)
DL1B (L)
(D)
DL4(K)
(K-L)
(K-L)
2' - 0" 2' - 8" 2' - 8" 2' - 0"
REF TO MECH PLAN
PL3 (F) PL3 (F)
TL1 (E)
16' - 8" COVE
(E)-(F)
SL1
REF TO MECH PLAN
DL4(K)
REPLACE ALUM
DOOR FRAME
WHERE DAMAGED
PROVIDE AIR
TRANSFER
OPENING IN
WALL ABV
CEILING FROM
CABINET TO
PLENUM
3
A-901
3
A-901
3
A-901
(N) SOFFIT,
MATCH OPP
A-603
1
A-602
1
(N) DOOR, REF TO CALLOUT
(E) SPA
(N) SCHLUTER-TROBA-LEVEL
PEDESTAL PAVER SHIMS, TYP
ALL JOINT INTERSECTIONS
(N) PORCELAIN PAVERS
3/4" THICKNESS, 24X48
6
A-901
6
A-901
6
A-901
(N) ALUM FIN SCREEN WALL
SL1
SL1
(M)
SL1
(M)
CONVERT (E) SINGLE
HOSE BIBB TO DOUBLE
BIBB OUTLET
A-901
8
A-901
8 A-901
8
EXISTING CABINETRY,
REMOVE (E) DRAWERS AND
RETROFIT W/ (N) DRAWER
BOXES, HARDWARE AND
FACE PANELS. PROTECT (E)
COUNTERTOP
SHEET METAL CLADDING
ATTACHED TO METAL FRAME,
POWDERCOATED BLACK.
MATCH HEIGHT OF SCREEN WALL
+48"
DL4 (N)
DL4 (N)
(H/I/N)
+36"
COORD
FRAMING
AND POWER
W/ AV
CONSULT
FOR DROP
PROJECTION
SCREEN (NIC)
SPLICE POWER AT (E)
OUTLET AND RUN (N)
CONDUIT BELOW PAVERS
TO OPP SIDE FOR NEW
ELECTRICAL WORK
(N) OUTLET AT 9"
DL2 (B)
DL2 (B)
2' - 10 1/2" 2' - 11" 2' - 10 1/2" 2' - 7"
PL2A
(C1)
3' - 6" 3' - 6"
DL1
(G)
DL1
(G)
DL1
(G)
DL1
(G)
DL1
(G)
3' - 5" 4' - 6"
2
2
COORD POWER FOR
AV PROJECTOR (NIC)
+66"
SL1
SL1
X3
SL1
X2
(P)
(P)
(O-P)
SL1 (E)
2
REFER TO ENLARGED KITCHEN PLAN
FOR ADDITIONAL INFORMATION
(N) WATER SHUT-OFF VALVES W/ LEAK
DETECTION SYSTEM TECHNOLOGY
2
2' - 0"
ROLLER SHADE
POCKER, REF
ROLLER SHADE TO DETAIL
POCKER, REF
TO DETAIL 2
2
PL2C
(C1)
PL2B (C1)
NEW 2-1/2" METAL FRAMING, 6" O.C.
W/ FLEXIBLE GYPSUM BOARD,
BEND AS INDICATED
R 1' - 2"
2
A-901
8
REF TO MECH PLAN
TO CL
10' - 0"
2' - 4"
5' - 11"
(N) OUTLET AT 9"
2' - 4"
EQ EQ
DL1B
(R)
1' - 0"
1' - 0"
2' - 6" 2' - 6"
SL1 X4
(Q)
DL1B
(O)
DL1B (O)
DL1B (O)
FLOOR PLAN LEGEND
NEW WALL W/ 2X4
METAL STUD FRAMING AND
MINERAL WOOL INSULATION AND
1/2" CEMENT BOARD (WET SIDE)
PAINTED GWB (OPP)
EXISTING WALL TO REMAIN
DUPLEX RECEPTACLE OUTLET
QUADPLEX RECEPTACLE OUTLET
CASETA WIRELESS IN-WALL
DIMMER PRO, 120V
4-BUTTON PICO WIRELESS SCENE
CONTROLLER: PROGRAM W/ OWNER
PRIOR TO PROJECT CLOSE-OUT
SB CASETA SMART BRIDGE
CT
DW
EH
ICE
MW
OV
ELECTRIC INDUCTION COOKTOP
RECESS FOR FLUSH INSTALLATION
DISHWASHER - CUSTOM PANEL
RECIRCULATING EXHAUST HOOD INSERT
CUSTOM PANEL AND HOUSING
ICE MAKER
CUSTOM PANEL REQUIRES DRAIN
MICROWAVE SPEED OVEN
CONVECTION OVEN
EQUIPMENT LEGEND
REF
SNK
SNKF
SO
VS
WS
FRIDGE/FREEZER
CUSTOM PANEL
KITCHEN SINK
KITCHEN SINK FAUCET
STEAM OVEN
VACCUM SEAL DRAWER
CUSTOM PANEL
WINE STORAGE
CUSTOM PANEL
CONSTRUCTION NOTES
(1) REFINISH ENTIRE APARTMENT FLOOR
INCLUDING UNDERNEATH FURNITURE (I.E.
CABINETS AND ISLAND). SAND (E) WOOD FLOOR TO
REMOVE COLOR. REFINISH WITH CLEAR, UV-CURED
WATER-BASED ULTRA MATTE SEALER. UV-CURED
SEALER IS FIELD-APPLIED AND REQUIRES SPECIAL
EQUIPMENT. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION. PERFORM A MOCK-UP
TEST FOR ARCHITECT AND OWNER REVIEW PRIOR
TO PROCEEDING WITH WORK.
(2) NEW BASEBOARD INSTALLED THROUGH ENTIRE
APARTMENT, REFER TO CONSTRUCTION DETAILS
FOR ADDITIONAL INFORMATION.
(3) PROVIDE NEW PAINT THROUGHOUT ENTIRE
APARTMENT ON ALL WALLS AND CEILINGS. SATIN
FINISH AT WALLS AND BASEBOARD AND MATTE
FINISH ON CEILING. CUSTOM COLOR TO BE
DETERMINED. PATCH AND REPAIR BATHROOM-1
CEILING FOR LEVEL 4 FINISH.
(4) PROVIDE DIMMING WIRE (NEUTRAL WIRE) FOR
ALL NEW LIGHTING.
(5) ALL LIGHTING WITHIN ROOM IS ON A SINGLE
SWITCH IF ZONING LETTER IS NOT INDICATED
(6) ROUTE ALL REMOTE DRIVERS TO AV CLOSET.
(7) RESERVED - REFER TO MECH PLAN.
(8) PROVIDE NEW WATERPROOFING AT
BATHROOMS. FURNISH AND INSTALL SCHLUTER
KERDI AT SHOWER PAN AND FULL-HEIGHT AT
WALLS AND LATICRETE 9235 AT ENTIRE FLOOR
AREA AND UPTURN 6" MINIMUM AT BASE OF WALL
WALL. LAP SCHLUTER KERDI OVER TOP OF
SHOWER CURB IN ACCORDANCE WITH
MANUFACTURER RECOMMENDATIONS.
(9) CONTRACTOR TO COORDINATE WORK WITH
OWNER'S AUDIO-VISUAL CONTRACTOR. AUDIO-
VISUAL CONTRACTOR WILL PULL THEIR OWN WIRE.
CONTRACTOR TO ASSUME MISCELLANEOUS PATCH
AND REPAIR.
(10) REFER TO ELEVATIONS FOR ADDITIONAL
REQUIREMENTS INCLUDING ELECTRICAL OUTLETS
NOT SHOWN ON PLAN.
(11) LED STRIP LIGHTING WITHIN CABINETRY AND
AT LAUNDRY CLOSET TO BE PROVIDED WITH
OCCUPANCY SENSOR SWITCH. CONTRACTOR TO
COORDINATE POWER AND WIRING REQUIREMENTS
WITH MILLWORKER. EXPOSED WIRING WILL NOT BE
PERMITTED.
(12) CONTRACTOR SHALL SUBMIT AN ELECTRICAL
LOAD LETTER TO ARCHITECT AND OWNER PRIOR
TO COMMENCEMENT OF WORK. NO ELECTRICAL
WORK PERMITTED OUTSIDE OF THE APARTMENT.
(13) INTERIOR DOOR PANELS ARE CURRENTLY
OBSERVED TO BE WARPED 1/2" OUT OF PLANE.
CONTRACTOR SHALL REMOVE ALL INTERIOR WOOD
DOOR PANELS, VERIFY STRAIGHTNESS AND
CORRECT AS NEEDED TO ACHIEVE 1/8" PLANAR
TOLERANCE. REPLACE EXISTING GLASS LITE WITH
LAMINATED PRIVACY GLASS AND PVB INTERLAYER
(GL2). SET HINGES AND HARDWARE, REMOVE, AND
FIELD-PAINT DOOR. CUSTOM COLOR TO BE
DETERMINED.
(14) ALL LIGHTING CONTROLS MOUNTED 44" TO
CENTERLINE, ABOVE FINISH FLOOR, U.N.O.
2
2
2
N
LIGHTING LEGEND
LED STRIP, COVE
MIN 3.5 W PER FT AVG 2700K 90 CRI
LUMINII OR APPROVED EQUAL
3" MINI LED RECESSED ROUND DN LIGHT (DL1)
15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-55-S-WH-NCE-UNV-D22-DEV
WHITE TRIMLESS FLANGE
8" BOLA SPHERE PENDANT (BRASS)
0-10v DIMMER OR ELV
MOUNT BOTTOM OF LIGHT 6'-0" ABV FF
OFCI
DECORATIVE WALL SCONCE
OFCI
SL1
DL1
DL3
TL1 TRACK LIGHT W/ (1) 12" ADJ MED SPOTLIGHT HEADS (TL1) LENGTH AS NOTED ON PLAN
11 WATT PER MODULE 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING CORONET MAGR-TRK-XX"-DR60-UNV-NT-BLK-DEV
CORONET MAG-SPMD-27-MED-BLK-FL-HEX-DEV
MUD-IN FLANGE W/ BLANK OFF
1" LED RECESSED ROUND DN LIGHT (DL3)
9 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI Z1RDL-09X1M-27KH-35-M0-BL-NC-RPD01-UNV-D6A-DEV WHITE COORD ACCESS FOR REMOTE DRIVER
WL1
PL1
DL4
1" LED RECESSED ROUND DN LIGHT, WALL WASHER (DL4)
9 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI Z1RWL-09X1M-27KH-W2-D1-BL-NC-RPD01-UNV-D6A-DEV WHITE COORD ACCESS FOR REMOTE DRIVER
TL2 TRACK LIGHT W/ (2) 12" ADJ MED SPOTLIGHT HEADS (TL2) LENGTH AS NOTED ON PLAN
11 WATT PER MODULE 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING CORONET MAGR-TRK-XX"-DR60-UNV-NT-BLK-DEV
CORONET MAG-SPMD-27-MED-BLK-FL-HEX-DEV
MUD-IN FLANGE W/ BLANK OFF
3" MINI LED RECESSED ROUND DN LIGHT, WALL WASHER (DL2) 15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-W2-S-WH-NCE-UNV-D22-DEV
WHITE TRIMLESS FLANGE
DL2
FOSCARINI RITUAL SERIES
CONFIRM DIMMING CAPABILITIES
MOUNTING HEIGHT VARIES FIELD-VERIFY
OFCI
PL2
ABCD
3" MINI LED RECESSED ROUND DN LIGHT (DL1)
15 WATT 2700K 90 CRI D3 LUTRON 2-WIRE DIMMING USAI B3RDL-15L2-27KH-65-S-WH-NCE-UNV-D22-DEV
WHITE TRIMLESS FLANGE
DL1
PL3 LED PENDANT
OFCI
1 BID SET 6/1/22
139 FULTON STREET #810 NY, NY 10038
******@*****************.***
ANDREARCHITECTURE.COM
(PH) 917-***-****
ARCHITECT
ANDRE ARCHITECTURE DPC
© 2021 ANDRE ARCHITECTURE
111 FULTON STREET PH110
NEW YORK, NY 10003
PROJECT
APT RENOVATION
2 2ND BOARD SUBMITTAL 7/29/22
# ISSUE DESCRIPTION DATE
3 FOR CLIENT REVIEW 8/28/22
4 FINAL BID SET 9/29/22
A-101
ARCHITECTURAL
PLAN
1/4" = 1'-0"
1
ARCHITECTURAL PLAN
CLR
4' - 5 1/4"
7' - 3"
FULL-WIDTH
SHOWER NICHE, T1
ST1
GLASS
MOUNTED
TOWEL BAR,
OFCI
2' - 6"
4" (H) CURB
ST1 CLAD ALL SIDES
UNDERMOUNT
SINK, OFCI
TUB
MATCH
2 A-601 5
3
A-601
4
1' - 2"
4-1/2" CLR
6
PROVIDE
POWER OUTLET
IN BOTOM
DRAWER OF
BASE CABINET
60X24
60X48
NUHEAT STANDARD ELECTRIC HEATING
MAT 120V W/ PROGRAMMABLE
THERMOSTAT AND WIFI-ENABLED,
STANDARD SIZES AS INDICATED
ST1
PONY WALL - ST1
CLAD ALL SIDES
T3
(E) DRAIN TO
REMAIN IN
PLACE
SAWCUT SURFACE
TREATMENT FOR
SLIP RESISTANCE
SHWRHNG
1' - 2"
CUSTOM
VANITY
MIRROR
115
CLR
3' - 6"
(E) TUB
9"
3' - 0 1/4" 4 1/4"
EQ EQ EQ
LED TAPE LIGHT AND
POWER RECEPTACLES
FOR LIGHTING DRIVER
LED TAPE LIGHT AND
POWER RECEPTACLES
FIXED MIRRORED GLASS
W/ CUSTOM LIGHT BOX
INTEGRAL GROOVED
EDGE PULL
7' - 3"
1"
7' - 1" 3' - 2 3/4"
T1
3' - 8" 3' - 0"
CUSTOM MILLWORK
EXT - WD1
INT - PL1
IN-DRAWER POWER RECEPTACLES
MIN 4-OUTLETS.
NO EXPOSED WIRING PERMITTED.
CUSTOM MIRROR CABINET
4 INT - PL1
A-604
LED TAPE LIGHT
5
A-604
2
REF TO DETAIL CALLOUTS
FOR ADDITIONAL POWER
REQUIREMENTS
WALL MOUNTED FAUCET,
OFCI
6' - 4"
GAP FILLER, 1" REVEAL
W/ MIRROR FINISH
1"
1' - 3"
8
A-902
2 1/4"
T1
3' - 8" 3' - 0" 3' - 2"
4' - 0" 1' - 9"
GL1
ST1
GLASS SWING
DOOR, GL1
(E) TUB
2' - 4"
8' - 0"
GLASS MOUNTED TOWEL BAR
OFCI
3' - 9"
PAINTED GWB
2' - 4"
EQ EQ
GLASS SWING DOOR
GL1
GL1
T1
ST1
GLASS MOUNTED DOOR HANDLE
OFCI
4' - 0"
3' - 8"
CHROME TILE TRIM
2' - 1" 1' - 9"
3' - 8" 3' - 0" 3' - 2"
T1
SHOWERHEAD
OFCI
SHOWER COLUMN W/ HAND WAND
OFCI
DIVERTER VALVE
OFCI
SHOWER CONTROLS
OFCI
4' - 0"
3' - 8"
T1
PAINTED GWB
LIGHTING CONTROLS
PC1
BATH
CONTROLS
OFCI
CHROME
TILE TRIM CHROME TILE TRIM
CONSTRUCTION NOTES
(1) ALL FIXTURES AND APPLIANCES ARE OWNER
FURNISHED, CONTRACTOR INSTALLED.
CONTRACTOR SHALL COORDINATE
MANUFACTURER REQUIREMENTS FOR COMPLETE
INSTALLATION INCLUDING POWER, WATER, AND
DRAINAGE. CONTRACTOR SHALL FURNISH AND
INSTALL CUSTOM