CURRICULUM VITAE

STATEMENT OF PURPOSE

CONTACT INFORMATION: I aspire to have a successful career in Electrical engineering and I crave

for challenging and motivating work in the field of Electrical.

Nilesh Lakhabhai Zala

ACADEMIC RECORD

Mobile : +91-982*******

Home : +91-635*******

I have completed I.T.I. from NCVT Rajkot with 66.65 % in

E-MAIL: 2011.

adztkj@r.postjobfree.com I have completed my S.S.C with 58.72% from GUJARAT

SECONDARY EDUCATION BOARD in 2008.

ADDRESS:

EXPERIENCE

At. Vadodara Zala,

Ta. Sutrapada, I Working as Sr.Technician in Thermal power plant

Dist. Gir Somnath. (45mw) of Electrotherm India Ltd at Samkhiyali-Kutch

Pin (362275) Gujarat. since 1st August 2022 to

h till date.

PERSONAL DETAILS:

I worked as Sr Technician In Thermal power plant (2*30

MW) of Shreeyam Power th and Steel Industries Ltd at

Ghandhidham since 11th November 2021 to 25th July 2022.

PERSONAL DETAILS:

DATE OF BIRTH : 7th May 1993 I worked as a Sr. Technician in Captive Thermal power

plant (25 MW, 18 MW & 8 MW) of Gallant Metal Ltd.

SEX: MALE (Gallant TMT Bars) at Samakhiyali Ta. Bhachau Dist. Kutch

since 16th Nov 2020 30 Oct 2021 & 10th Aug 2013 to 02nd

NATIONALITY : INDIAN May 2018.Technical Tasks are as below,

MARITAL STATUS : MARRIED Operation and maintenance of three units of TG sets

respectively 25 MW (ANDRITZ make) Rated voltage: 11 KV,

Rated current: 1640 A, Rated power factor: 0.8 lagging, 18

LANGUAGES KNOWN: MW (TDPS make) Rated voltage: 11 KV, Rated current: 1181

A, Rated power factor: 0.8 lagging & 8 MW (TDPS make)

Gujarati Rated voltage: 11 KV, Rated current: 525 A, Rated power

Hindi factor: 0.8 lagging and Protection Scheme of each generators

by SIEMENS SIPROTEC 7UM62 and 5 nos of WHRS boilers and

a 150 TPH of ISGEC make CFBC boiler with 107 kg/cm

PREFERED LOCATION: pressure and a 100 TPH of Thermax make AFBC boiler with

105 kg/cm and their auxiliaries.

Anywhere in Gujarat. Synchronization of all generators and grid using manual

system as well as Woodward Load Sharing Auto sync system.

EXPERIENCE IN YEAR:

Day to day maintenance of Elect Inst like HT / LT Circuit

Total 11 year Experience in Breakers, DOL-RDOL / Star Delta Starters, Different kinds of

power Plant. relays & Variable Frequency Drives, HT/LT Underground cable

joints and Termination etc.

Looking after 500 KVA Emergency DG set along with

auto/manual system.

Operation and maintenance of Power Plant utilities like RO &

DM Plant, Compressors & Driers, Cooling Tower, and Coal

Handling Plant etc.

I have worked as a Sr. Technician in Thermal power plant

(10 MW) of Abellon Clean Energy Ltd. at Savarkundla Dist.

Amreli from 5th may 2018 to 14th Nov 2020.

Operation and maintenance of SJPEF china make and its

auxiliary

O & M of VCB 1250A ABB make.

O & M of all switch yard based equipment's like LA, CT, PT,

Transformer, Isolator.

Ability to attend emergency like system failure, load failure,

station blackout, etc.

O&m of all type of breakdown of HT panel, LT panel, LAVT

panel, NGR etc.

Operation and maintenance of three units of TG sets

respectively 25 MW (ANDRITZ make) Rated voltage:

11 KV, Rated current: 1640 A, Rated power factor: 0.8

lagging, 8 MW (TDPS make) Rated voltage: 11 KV,

Rated current: 525 A, Rated power factor: 0.8 lagging and

Protection Scheme of each generators by SIEMENS

SIPROTEC 7UM62 a 100 TPH of Thermax make AFBC

boiler with 105 kg/cm and their auxiliaries.

Day to day maintenance of Elect Inst like HT / LT Circuit

Breakers, DOL-RDOL / Star Delta Starters, Different kinds

of relays & Variable Frequency Drives, Amtech & ABB make

AVR with BLDC, VCB up to 2500A, HT/LT Underground

cable joints and Termination etc.

I have worked as a Technician in Captive Thermal

power plant (2*6 MW) of Mono steel Ltd. At Bhachau,

Kutch from Aug 2011 to July 2013.

O&M of generator with 1500 RPM of TDPS make.

O&M of ACB upto 3000A of L&T make.

O&M of VCB upto 1200A of Siemens make.

O&M of power transformer with relay panel and control

panel.

SST – 1.5 MVA, 11KV/440v

ESP transformer 110 KV 1000 ma

O&M of MCC, PCC, Relay panel, AVR panel.

O&M of 10 MVA 66kv/11kv transformer with OLTC of T&R

make.

DECLARATION

I confirm that the information provided by me is true to the best of

my knowledge and belief.

Photo copies of all the objects mentioned above are attached with

this application.

Place:

Date:

Yours Sincerely,

Nilesh Zala