Post Job Free

Resume

Sign in

Wind Turbine Renewable Energy

Location:
Morbi, Gujarat, India
Salary:
30% hike
Posted:
September 30, 2023

Contact this candidate

Resume:

SHUBHAM BHAWSAR

Sr.Engineer at Siemens Gamesa Renewable Energy

PVT.LTD.Gujarat Mobile: 999-***-****

E-Mail:adz2c7@r.postjobfree.com

Bachelor of Engineering Electrical &

Electronic

Looking forward for a challenging position, where I can utilize my engineering and interpersonal skills, which avail me anopportunity to learn new things and explore future career possibilities. PROFESSIONAL PROFILE

B.E. in Electrical and Electronic Engineering with over 7 years 1 month of experience.

Currently associated as Sr.Engineer with Siemens Gamesa Renewable Energy PVT. LTD.

Different kind of Work shop attended like Management and Team Building, etc.

Detail oriented with an analytical bent of mind and a positive attitude. ORGANISATIONAL EXPERIENCE

Siemens Gamesa Renewable Energy PVT.LTD

Designation: Sr. Engineer

Department: Operation & Maintenance Service

Duration : May 2022 to Till Date.

Troubleshooting and perform root cause analysis to prevent re-occurrence

Ensuring safety and manual handling tools and material on Wind turbine operations

Experience in commissioning of new projects and taking it over to Operations

Pre-commissioning & Commissioning done in G114 & G97

Maintaining the wind turbine generators to operate at its optimum standards

Planning with the teams and department for smooth operation of the site.

Operation & Maintenance of DFIG 2.1 MW

Accountable for conducting TBTs for contractors and on-role employees

Well Known in Operation and maintenance & Troubleshooting of Hydraulic system.

Operation and maintenance of dry type transformer of 2350 KVA.

Well known in software Installation on PLC & Ingeteam and other WTG software programming.

Trouble shooting of PLC system and various I/O modules

SCADA monitoring with analysis and OFC network trouble shooting

Major Activity done with team “Generator replacement, Gearbox replacement & Transformer replacement donethrough crane.

Generator alignment taken through laser kit & Mechanical Alignment Kit. SUZLON GOBAL SERVICE LTD

Designation: OMS Quality Auditor Sr. Engineer

Department: Operation Maintenance Service Quality

Duration : October 2021 to April 2022.

Auditing, analysis, MIS, Documentation, Validation, Quality Management

350KW to 2100 KW wind turbine generator, 33KV Electric Line & Grid Sub Station technical Auditcarried out

Audit NC data analysis and Solve repetitive NC problems using 8D

Aware Employs by Training Serious impact of NCs on turbine health using 80/20 analysis

Maintain, Sustain & Improve Turbine health & its Performance by 100% tracking & NC Closing by OMSteam

Resolve Customer Query with CRM MOM & Provide immediate CAPA SUZLON GOBAL SERVICE LTD.RAJASTHAN

Designation: OMS Engineer

Department: Operation Maintenance & Service

Duration : Jan 2018 to October 2021 date.

O&M at TEJUWA 100.8MW Plant Tejuva Site Jaisalmer (2.1 MW S9x DFIG V2- 48WTG)(Raj)..

Job Profile: -Work mainly focused on Operation and Maintenance of Wind Turbine Generator. Performance monitoring of equipment, Asset Management, Safety adherence of man & machine, Manpower management,Materialmanagement, Maintaining ISO documentation, Maintaining SCADA system and Customer interaction,MTBF, Maintenance Planning for WTG,Material Planning, Monthly Presentation Site performance& review(Machine Availability, UA/UC,PPE,s Details, MRS vs NCR, MTBF & MTTR,Power Curve,PM NC material,Site Manpower details,Kaizen,5S details,LIFT,Winch FTU certificate,Thermography details etc.).

Functional Role:

Daily POD of site & same conformation in Evening Plan Vs Actual. 1. Maintenance Supervising

2. Maintenance Planning

3. Daily maintenance Report

4. Man power planning shift wise & material handling 5. TOOL BOX TALK-Every Day

6. Availability of stock i.e. man. Machine & material for continues production & smoothmaintenance activity 7. Maintenance Process

8. work order in SAP

9. PM NC details & Material availability at site

10. Take care of corrective action & preventive action (CA/PA) in the report of investigation 11. Knowledge of electrical drawing (Top, bottom, DFIG & Hub All type), found out failure component & replace.Detection and rectification of fault of PLC based. 12. Managing the functions of troubleshooting and preventive / breakdown maintenance ofWTG. 13. MTBF

14. MRS VS NCR

15. Power Curve Analysis & Predictive Analysis

16. WTG under running in Reduce power rectification work 17. Less than 96% WTG analysis

18. Knowledge of Power & communication Slip Ring, Motor(1.1 / 1.8 KW, 3.2 KW, 5.2 KW ), DFIG Chock,Powerstack DFIG, Contactor, relay,MCB / MPCB, 80,125,710 A Fuse,Panel fan, Convertor, Capacitor in WTG.

19. Working knowledge of CAN protocol & Ethernet.

20. Knowledge of different types of sensor likes temperature sensor, limit switch, Proximitysensor, vibration sensor andwind sensor.

21. Transformer BDV Test, IR Value, WTI,OTI, MOG & Buchholz relay testing .8 transformer 2500 KVA changing WTG.

Major Work.

Generator DE & NDE Bearing change, Take generator alignment reading by laser alignment, Generator fanmotor change.

Gear Box -Gear box check by endoscopy, check Gear box radiator working, GB Hose pipe oil leakagearrest

,gear box Oil change work, Radiator cooler motor change

Transformer –BDV Test, IR Value, WTI, OTI, MOG & Buchholz relay testing .8 transformer 2500 KVAchange in WTG.

24 HPCL wind Project HOTO complete & STPT complete with in record one month.

GEAR Box, Main bearing, Generator, Transformer, Blade, Yaw drive, Pitch Drive, Pressure plateRepaired/Change work

CLS- central lubrication system must be required for rotating part with well working Slew Ring lubber, Pinion Lubber, Main Bearing Lubber & Generator lubber Its working, grease full fill, Lubber componentchange work

ACB,VCB,DFIG LSC & MSC,Chock,check & change work Siemens Gamesa Renewable Power Pvt ltd.

(JAAC SERVICE)

Designation: OMS Engineer

Department: Operation Maintenance & Service

Duration : August 2016 to January 2018 date.(Radhanpur Gujarat) Turbine Services

Total Site Capacity 206 MW

Worked On G5x and G9x DFIG Model (850 and 2MW)

Plan and Execute Maintenance and Service of wind farm.

Strong command on Fault finding and Troubleshooting of Electrical, Mechanical & Hydraulics.

Holding accountability towards customers and Investors regarding Profit and Generation.

Single Point of contact whether for technical issue and Management as well.

Look after Material Management and Accounts.

Pre-commission & commission.

MAJOR WORK

Pitch cylinder replacement.

Oil seal replacement for pitch cylinder.

TC marking.

PROFESSIONAL & ACADEMIC QUALIFICATION

2011: 12th 55%from SVM Soyat Kalan.

2009: 10th 56%from SSVM Soyat Kalan

PERSONAL INFORMATION

Father’s Name : Vijay Kumar Bhawsar

Date of Birth : February 20, 1994

Permanent Address : Makan No.04, Ward NO.08, Bhawsar Maholla soyat kalan Dist. Aagar Malwa (M.P) Linguistic Abilities. : English & Hindi.

Hobbies : Cooking, Chess, Internet, Technical Troubleshooting. Declaration

I declare that all the information and facts stated above are true and correct to the best of my knowledgeand belief.

Date: - 2 8 /09/2023 SHUBHAM BHAWSAR

Place

2015 Bachelor Degree in Electrical & Electronic Engineering (5.84) from Chameli Davi Groupof institutions in INDORE, (RGPV).



Contact this candidate