EXPERIENCE: I have 15 years of progressively responsible experience at Onshore as an Instrument Technician/Instrument Foreman/Instrument Supervisor/Instrument E&I QC in Refinery, Oil & Gas sector and Power Plant qualifies me for this position. I have good exposure in Oil and Gas Plant, Petrochemicals and Power Plant. I have experience in Kuwait, Qatar, Kingdom of Saudi Arabia and Philippines.
I am very comfortable in an environment which demands a variety of task including such activity as routine maintenance of plant, project construction and commissioning with the safety standard of industry like Siemens, Shell, KNPC, Qatar Gas, RasGas, AramCo, Sabic, SOCC AG&P Bechtel Saipem and AG&P JG Summit.
I have knowledge in installing variety of system, such as Refrigeration and Air Conditioning and Ventilating duties like planning work, assigning task, supervising mechanics, ensuring system, and preparing repair cost estimate are often seen on HVAC.
SKILLS
Leading a team consists of Instrument Technician, Instrument fitters and Electrician for installation commissioning and maintenance of process control instrumentation field.
Having good knowledge of plant safety rules and regulations.
Good knowledge about Permit to work system (PWS) and several kinds of permit like cold work permit, hot work permit, limited space entry permit.
Familiarity of several kind of Perilous involved in work area and essential safety measure to be done for the safe work.
Capacity to do job alone by following Safety rules and regulation.
Good experience in Plant Maintenance and Commissioning.
Sound knowledge and good experienced in the management Plant Instrument Maintenance.
Experienced in the Boiler Management System (BMS).
Specialist in the installation and calibration of different types of the modern smart electronic and pneumatic instrument.
Skilled in PLC, DCS, ESD Plant Automation Control System.
Effective knowledge of the Lock out Tag out processes.
Operational knowledge in Fire and Gas Systems like HC Detectors and UB, H2S Detectors and Smoke detectors.
Sounds skills of all kind of rotating equipment maintenance, gas turbines compressors etc.
Operational knowledge in a Turbo-Tronic Turbine Control System.
Able job independently.
Skilled to read Engineering drawing, Loop Diagrams, P&ID drawing, Logic Diagrams and Hook-up Drawing.
Assessed customer service needs, repaired and installed appropriate components. Travelled extensively throughout assigned and existing customers.
Maintained professional customer relationships to update customer on project status.
Achieved high ratio of customer satisfaction and lowest rate of repeat service call for initial installation.
Installed repaired and maintained all HVAC equipment within assigned area of responsibility.
Planned and scheduled the teamwork assignment. Communicated status for work project senior.
Install compressors, evaporator’s motor duct and piping as well mechanicals/electrical controls: read and interpret blueprints/diagram.
WORK EXPERIENCE
AG&P/CTCI JG Summit Project
JG Summit Petrochemicals Expansion Project
Brgy. Simlong, Batangas City, Philippines
Position: Instrument and Electrical Foreman
From May 7, 2019 up to May 30, 2021
Construction
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Ensure compliance with the site cardinal safety rules and with all safety aspects in the execution of work.
Complete field level risk assessments.
Construction activities- Electrical/Instrument in my career. My major role is involved in electrical, installation and commissioning departments and familiar in carryout planned activities.
Handling different types of HV/MV, MV/LV transformers, switchgear, diesel generator. HV/MV/LV motor and associated switchgear/starter, MCC panel, UPS/battery chargers, batteries, catholic protection system, heat tracing system, lighting system, and plant earthing system.
Instrument air pipe line, instrument analyser house, bundle tube connection to the process line etc. in Petrochemical plant.
Installation of grounding cables/cad weld.
Do inspection of Electrical/Instrumentation installation as per ITP and testing activity at site.
Manage inspection test record in order to turn over system to client.
Coordinate with vendor for testing and modification activities at site.
Answer technical queries and provide continuous assistance to engineering to solve site related issue.
SAIPEM Sharjah-United Arab Emirates
Al Saadah Tower, Near Chambers of Commerse Al Mazar
Sharjah- United Arab Emirates
Position: Instrument Supervisor
From May 15, 2015 to May 10, 2018
Construction
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Ensure compliance with the site cardinal safety rules and with all safety aspects in the execution of work.
Complete field level risk assessments.
Use of calibration and testing instruments to inspect, test and perform troubleshooting and diagnose faults.
Successfully and safety installed various type of pressure transmitter, temperature transmitter, flow transmitter, and pneumatic instrumentation onto oil and gas module.
Exhibited safe tube bending and connection techniques using various size of stainless steel tubing for instrumentation; single and multiple tubing lines. Applied mathematical aptitude to ensure an accurate radius measurement for tube bending.
Installed pneumatic airlines using various sizes of carbon, galvanized, and stainless steel pipeline.
Displayed advanced knowledge of job safety analysis procedure and worked safety without incident in production area.
Do the installation of Airlines Pipelines.
Installation sample gas probes.
Installation of Thermox Flue Gas Analyzer,
Installation of different types of switches such as PSH pressure switch alarm high, PSL pressure alarm low, flow switch, manual alarm call point and pressure gauge.
AG&P Bechtel LNG Module Yard Project
Electrical & Instrumentation
San Roque, Bauan, Batangas Philippines
Position: E & I PBQ Inspector Hazardous
From July 24, 2013 up to July 2, 2014
Planning and manage the work load.
Implementation of quality plan for this project, which include inspection, testing and proper documentation and ensure that all works complied with client/contractor issued (IFC) drawing, applicable standards and specification.
Implementing coverage of proper installation, wiring and cable laying, cladding, termination, witnessing of insulation resistance test and hipot test.
Ensure that all related inspection and testing activities with regards to Environment, Health & Safety procedures and maintenance rules are respected.
Monitor the performance of construction to ensure the respect of work standards and project specifications.
Perform proactive surveillance inspection to minimize or avoid discrepancy and non-conformance rectification cost and time.
Coordinate and assist construction to resolve any encountered problems related to inspection and testing activities to meet schedule and avoid any delay of activities.
Initiate remedial or corrective action based on standard, code, and specification and verify the closure of NCR.
Inspect and witness the construction works as per their approved Inspection Test Plan.
Invite client/contractor for witness and hold points in Inspection/Test.
Ensure the effective coordination with the client related to inspection, testing activities and documentation.
Ensure the implementation of Contractual Inspection and Tests.
Prepare internal punch list and coordinate with the construction prior for inspection.
Coordinate with the client for punch list closure and final acceptance.
Witness and liaise with vendor/contractor for any related electrical equipment testing activities.
Maintain all Quality Control Report. Specification check on instruments i.e. temperature gauges, Thermocouples pressure gauges, control valves, transmitters, manifolds etc. Writes request for inspection (RFIs).
Issue NCR on instruments installed that does not conform to the standards specified by the client.
Inspect and witness impulse lines, manifold, airlines installed, checking its height, slope, services, etc. in line with the specification.
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Samsung Engineering – Saudi Arabia
Jubail- SOCC. AA Project
Saudi Organometallic Chemical Company
P.O. Box 35816, Jubail Industrial City 31961,
Kingdom of Saudi Arabia
Tel. No. +966-*-***-****
TeleFax: +966-*-***-****
Position: Instrument Supervisor
From December 25, 2011 up to May 15, 2013
Construction commissioning up to start up.
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Ensure compliance with the site cardinal safety rules and with all safety aspects in the execution of work.
Complete field level risk assessments.
Safely perform commissioning, testing, troubleshooting and diagnose faults on the following:
Calibration checks of field instrumentation.
Stroke test of pneumatic hydraulic and motor-operated valves.
Loop checks and troubleshooting I/O (Input/Output) checking and troubleshooting.
Fiber optic panels wiring against IFC (Issued for Construction) drawings and redlining/ as building as required.
Cause and Effect matrix checks
Interlocks, alarms and control performance verification.
Installation inspection against design documentation.
Completion of approved commissioning check sheets.
Use of calibration and testing instruments to inspect, test and perform troubleshooting and diagnose faults.
Communicate design discrepancies and design issues to the commissioning operations manager and the site project manager.
Successfully and safety installed various type of pressure transmitter, temperature transmitter, flow transmitter, and pneumatic instrumentation onto oil and gas module.
Exhibited safe tube bending and connection techniques using various size of stainless steel tubing for instrumentation; single and multiple tubing lines. Applied mathematical aptitude to ensure an accurate radius measurement for tube bending.
Installed pneumatic airlines using various sizes of carbon, galvanized, and stainless steel pipeline.
Displayed advanced knowledge of job safety analysis procedure and worked safety without incident in production area.
Samsung Engineering – Saudi Arabia
Jubail- ASU Project Gas Phase VIII Air Separation Unit
P.O. Box 35816, Jubail Industrial City 31961,
Kingdom of Saudi Arabia
Tel. No. +966-*-***-****
TeleFax: +966-*-***-****
Position: Instrument Supervisor
From April 18, 2011 to December 24, 2011
Installation of different type of switches such as PSH, pressure switches high. PSL pressure alarm low, flow switch manual alarm call point and pressure gauge.
Installation of process variable equipment transmitter flow, pressure, level and temperature instrument, as well as their stancion, cable tray, impulse line and installation tubing support.
Loop check.
Hook up work for analyzer and other instrument.
Tube connection for analyzer by using hook up.
Fabricating welding support for analyzer tube.
Installation cylinder calibration gas for analyzer.
Cable glanding and termination for analyzer junction box.
Calibration and setting for toxic gas and infrared gas.
Instrument loop test for fire and gas detector and functional loop test for analyzer transmitter.
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Construction commissioning up to start up. Ensure compliance with the site cardinal safety rules and with all safety aspects in the execution of work.
Complete field level risk assessments.
Safely perform commissioning, testing, troubleshooting and diagnose faults on the following:
Calibration checks of field instrumentation.
Stroke test of pneumatic hydraulic and motor-operated valves.
Loop checks and troubleshooting I/O (Input/Output) checking and troubleshooting.
Fiber optic panels wiring against IFC (Issued for Construction) drawings and redlining/ as building as required.
Cause and Effect matrix checks
Interlocks, alarms and control performance verification.
Installation inspection against design documentation.
Completion of approved commissioning check sheets.
Use of calibration and testing instruments to inspect, test and perform troubleshooting and diagnose faults.
Communicate design discrepancies and design issues to the commissioning operations manager and the site project manager.
Samsung Engineering – Saudi Arabia
Aramco (Saudi Arabian Oil Company) Project
P.O. Box 35816, Jubail Industrial City 31961,
Kingdom of Saudi Arabia
Tel. No. +966-*-***-****
TeleFax: +966-*-***-****
Position: Instrument Foreman
From February 11, 2010 to April 11, 2011
Do the installation of Airlines Pipelines.
Installation of sample gas probes.
Installation of Thermox Flue Gas Analyzer.
Installation of all types of transmitter using hook-up.
Installation of bundle tube for analyzer and connection for gas probe.
Calibration and installation of thermocouples, instrument LCP, EHS, field instrument, and process airlines pipe line.
Installation of different types of switches such as PSH pressure switch alarm high, PSL pressure alarm low, flow switch, manual alarm call point and pressure gauge.
Do the installation that includes instrument hook-ups, instrument termination, instrument calibration, and instrument loop checking.
Installation of process variables equipment transmitter– Flow, Pressure, Level and Temperature instrument, as well as their stanchion, cable tray and impulse tubing support.
Calibration and installation of fire, gas, and smoke detectors.
Installation of instrument panel analyzer, cable tray and fabricating welding of support.
Read and interpret drawings related to control, electrical and instrumentation systems such as P&IDs, loop drawings and other system documentation.
Construction commissioning up to start up.
Dae Myung Company – Qatar Gas
Laffan Refinery Project
P.O. Box 60977 Al Khor, Doha, Qatar
Position: Instrument Foreman
From November 9, 2007 – November 10, 2009
Calibration and installation of thermocouples, instrument LCP, EHS, field instrument, and process airlines pipe line.
Installation of different types of switches such as PSH pressure switch alarm high, PSL pressure alarm low, flow switch, manual alarm call point and pressure gauge.
Do the installation that includes instrument hook-ups, instrument termination, instrument calibration, and instrument loop checking.
Installation of process variables equipment transmitter– Flow, Pressure, Level and Temperature instrument, as well as their stanchion, cable tray and impulse tubing support.
Calibration and installation of fire, gas, and smoke detectors.
Installation of instrument panel analyzer, cable tray and fabricating welding of support.
Construction, commissioning up to start up.
Safety and Fire Expert
KNPC Project
Maintenance
Mina Abdullah, State of Kuwait
Position: Instrument Technician
From June 5, 2005 – June 7, 2007
Instrument loop test for fire and gas detector.
Calibration and testing for toxic gas and infrared gas detector.
Functional loop test for instrument detector.
Operational test procedure and start-up of fire water pump station from lower upper section.
Hook-up work for analyzer and other instrument.
Maintenance and calibration of control valves.
Lay-out and installation work for fire and gas detector.
Application for H2S gas 10-50% PPM for toxic gas methane gas 20-50% LEL for infrared gas detector.
Technical support for the instrumentation team.
Experience in flow meters configuring.
Experience in the field instrument and control system procurement activities.
RAE System
Service Level 1 Training
Dubai
January 26 & 27 2006
Calibration and setting for toxic gas and infrared gas detector.
Validation, Termination and Maintenance.
Application for H2S gas 10-50% PPM for toxic gas methane gas 20-50% LEL for infrared gas detector application
First Gas Power – Siemens Power Operation Inc. Project
I & E Industrial System Services, Inc.
76 Libjo Takad, Batangas City
Position: Instrument Technician
From November 08, 2003 – July 26, 2004
Calibration and repair of different instrumentation such as vessel and plant equipment.
Installation of process variables equipment – Flow, Pressure, Level and Temperature instrument, as well as their stanchion, cable tray and impulse tubing support.
Continuity test from point of field instrument cable in the control panel, termination of field instrument cable in the junction box of Flow, Pressure, Level, Temperature instrument and control valve.
Calibration of field instruments prior to clients request.
Prepare complete documentation and checklist.
Philip Morris Greenfield
Maintenance
Sto. Tomas, Batangas
Position: Instrument Technician
From May 31 to August 31, 2003
Engage in instrument maintenance, Calibration, Start-up, Loop checking, installation, troubleshooting and repairs of various type of instruments involve in Philips Morris.
Philip Morris Greenfield Project
Siemens Bldg. Technology
Sto. Tomas, Batangas
Position: Instrument Technician
From September 7, 2002 to May 7, 2003
Do the installation and pre-commissioning of BMS (Building Management System) using Siemens PLC, these includes instrument hook-ups, instrument termination, instrument calibration, instrument loop checking and assist in commissioning.
Shell Refinery Project
OSA Industries Phils. Inc.
Libjo Tacad, Batangas City
Position: Valve Technician
Shutdown May 11, 2002 – June 11, 2002
First Gas Power Corporation 1000MW CCPS Project
Siemens Inc.
Sta. Rita, Batangas City
Position: Instrument Technician
From November 16, 1999 – August 31, 2000
Calibration and setting for analog and digital instrument by using hand pump calibrator and digital monometer and manometer gauge test equipment.
Cable glanding and termination for field instrument junction box.
Hook-up working for field instrument.
Pre-commissioning test and start for field instrument.
ON THE JOB TRAINING
EEI Corporation
Sta. Maria, Bauan Batangas
Draftman Trainee
April 26, 1998 – August 1998
Coordinates with one who involves in the preparation of the piping spools for field fabrication/ installation and performs other related works as field verification and gather technical data that maybe required. Prepared piping standard details and isometric drawing base in the plan by using AutoCAD.
Prepare and encode fabrication schedule, monitoring sheets and miscellaneous form.
EDUCATIONAL BACKGROUND
Certificate : National Certificate II
Instrumentation and Control Servicing
Concept Institute for Career Enhancement, Inc.
August 28, 2018 to August 27, 2023
: Blue Dog Training
CPC10108 Certificate I in Construction
Card Number 1635716 (31/01/2013)
: RAE Systems
Service Level I Training
Dubai January 26-27, 2006
Course : Industrial Instrumentation Course
I & E Industrial System Services Inc.
TESDA, P. Herrera St., Batangas City
From February 2002 to April 2002
Module 1 : Basic Instrumentation
Module 2 : Process Variables
Module 3 : Validation, Calibration and Maintenance of Industrial Equipment
College : University Of Batangas
Hilltop, Batangas City
Drafting Technology and Computer Aided Design
1996 to 1999