Project Manager Electrical Engineer

Location:
Cairo, Cairo Governorate, Egypt
Posted:
June 14, 2023

Contact this candidate

Resume:

Curriculum Vitae

Personal data: -

Name : Wael Mohammad Rashad Ali

Religion : Muslim

Date of birth : 17/9/1978

Nationality : Egyptian

Marital Status : Married.

Address : Zagazig City- Al-sharqiyah

E-mail address : adxpa2@r.postjobfree.com

Telephone : 002**********

Mobile no : 002 010********

Studying file: -

Qualification : Faculty of Engineering – Zagazig University Grade : B.Sc on 2003 Electrical-Power Engineering

Experiences: -

PRESENT EXPERIENCE IN Egypt:

Electric Power Systems Engineering Company

From July 2017 till now

Position: Substations Section Head (Deputy Substations Sector Director)

- Receiving the Committee's decision from EETC regarding new substations construction and preparing Single Line Diagram, Study, make the complete package of the scope of work, Technical data schedules, materials price schedule and contract of each substation as the following below:

El-Eqtsadiya (2) 500/220/66/22 kV GIS S/S

El-Hawamdiya 500/220/66/11 kV GIS S/S

West Damietta 500/220/22 kV GIS S/S

Extension of Damietta (1) 220/66/11 kV GIS S/S.

PS4 66/11 kV AIS Substation

Water Filtration 66/11 kV AIS Substation

Responsibilities:

[Site visit], [Preparing the tender documents], [Technical and financial evaluation], [Design review during construction phase] Also, make the necessary letter for requirements such as Line protection and communication requirements at remote ends, soil investigation test report, substation location and four corners coordinates.

- Make the necessary analysis for the received technical offers and commercial offers of the proposal by the contractors.

- Make the analysis for the technical offers and commercial offers and after that finalized the final technical and financial report, then submitted to the Client after finish the bidding.

- Attending the factory acceptance test for the major materials.

- Review the base design and detail design for the final approval.

- Attending the factory acceptance test for three (3 Nos.) 175 MVA Power Transformers for Obour 5 220/66/22 kV GIS S/S from 20/10/2019 up to 31/10/2019 at Changzouh XD power transformers factory part of XD China, in Changzouh City – China.

- responsible for El Hawamdiya 500/220/66/11 kV GIS substation consulting work such as drawings, design, calculations and materials approvals review, monitoring the site progress and activities according to the overall time schedule of the contractor project.

- Technical Support consultant for West Bakr 220/33 kV GIS Substation for West Bakr Wind Farm on behalf with Lekela Advisor Limited from 15/8/2020 till 8/2/2021: Responsibility:

Review the technical guarantee with EETC according to BOO agreement.

Power Regulation Study review.

S4 Remote End Substation interfacing works with L&T contractor and canal electric zone

(Operating Committee).

220 kV OHTL Feeders Bays at S4 Substation allocation.

220 kV S4/West Bakr OHTL phasing arranging at the gantry in matching with West Bakr 220 kV Feeders bays Phasing according to the equipment Layout.

CT size calculations submission review for approval.

Necessary coordination with Protection Central Sector (EETC) for Final Setting issue.

33 kV Switchgear technical review after the waving from 33 kV AIS to 33 kV GIS SWGR due to covid 19 pandemic.

33 kV Switchgear short circuit current value in coordination with Operating Committee for confirmation.

220 kV Switchgear short circuit current value with Operating Committee for confirmation.

220 kV C.B numbers, C.T ratio and rating current (As-Build SLD) at S4 Remote Substation.

Telecommunications System technical review with EETC.

The standalone earthing resistance expected at the 6 towers closest to West Bakr Wind Farm Substation.

Identification of the interfacing works for each contractor Siemens EM and L&T.

Attending operating committee monthly meeting to close the technical related item.

Attending virtual visit for Nacelles & Hubs FAT at Siemens Gamesa Egypt office. EXPERIENCE IN SAUDI ARABIA:

Bin Omairah Co., LTD.

From June 2016 until June 15, 2017

Post. : Project Manager

Project: 115 KV Underground Cable Portion for Dammam Housing Substations Supply.

- Review and Follow up the technical approval from the base design stage up to getting IFC drawings.

- Preparing the invoices items with all supporting documents such as Clearance shipment certificate and materials inspection report.

- Monitoring the materials manufacturer and release up to getting material shipment certificate.

- Gassing and degassing preparations for 115 KV GIS of the cable feeder’s bay.

- Testing and commissioning preparation for the cable feeders at the remote substation.

- Remote End Modifications and interfacing for the line protection Panels.

- Sheath Voltage Limiter size selection and design. Professional Work Experience: Saudi Services For Electro Mechanic Works Company Limited (S.S.E.M) Owned by Al-Rashid Group Companies. P.O Box 6341 Riyadh-11442, Kingdom of Saudi Arabia.

From November 25, 2005 until June 2016

From June 2015 until June, 2016

Post. : Project Manager

Project: Installation of 115 KV Underground Cable for Az-Zuhoor-2 115/13.8 KV Substation in Dammam for National Grid, SA.

Following all response with National Grid for all activity like Base Design and Calculations for Power Cables, Joints, Terminations, Bonding/Grounding Cables and Soil Test Investigation. Also, the preparation for Execution work permit and necessary coordination with Municipality, Mobily, STC, Dammam Water Management and Saudi Electricity Company Maintenance for 380/230/115/69/13.8 KV Lines.

Review all Electrical Drawings and Interfacing drawings for 115 KV GIS Cables Head Box Dimensions of the existing 115 KV GIS.

Review the cable Ampacity and induced voltage from Power Cable Vendor. Review the existing facility such as Power Cables, Fiber Optic Cables, Water Pipes etc., coming on the cable route.

Finalized the detail design and approval for the above conditions and prepare Overall Plan and Testing Commissioning Plan.

From November 2013 until June 2015

Post. : Site Manager

Project: Construction of New 115 KV SADARA Substation for Marafiq SWRO in Jubail Responsible for all activities Civil, Mechanical and Electrical especially Remote End Modifications like SCADA, SOE, ANN., DFR and Tripping signal at 230/115 KV Jubail-2 S/S # 1. Also, Busbar Scheme check for the concern 115 KV Lines Feeders. From December 2010 to November 2013

Post : Protection Engineer and Acting Site Manager Project: Construction of New 380/115 KV Dhahran South BSP Substation Supervise115 KV GIS erections and testing up to High voltage test. Power Transformers erections and testing

Temporary Energization with West Khobar 115/13.8 KV Substation from our Remote End Half Moon 380/115 KV BSP Substation, all the modifications in the existing panels related to our feeder Dhahran South Line-2 SCADA, SOE, TFR, Ann., BB Protection and LCC panel. In addition review all schematic drawing for the new protection panel and update SCADA, SOE, ANN., TFR Point Lists and take approval from SEC-EOA plus control cable schedule updating and the work permit it was by my name after take SEC Permit work receiver certificate from Dammam Power Plant Also, I get permit clearance certificate to follow with master station. All interfacing drawing for this line updated as per the approved drawing in additional also, the interfacing with the communication panel and Fiber Optic interfacing panels for teleprotection system.

After Dhahran Substation finished completely we energized from Half Moon Line-1 and after that we getting outage Half Moon Line-2 re-routing and SCADA, SOE, TFR, ANN. Point Lists updated for Dhahran Line-2 and west Khobar re-energized from Dhahran South directly. From 2010 March to December 2010

Project: Construction of New 132/13.8kV King Saud University S/S 8137, Riyadh Post : Testing & Protection Engineer

Responsibilities:

In King Saud University Substation No. 8137 in Riyadh as Testing and commissioning Coordinator with SEC-COA, also follow up all snags and the modifications as per SEC-COA requirements like:

Busbar protection modification in DC circuit for Busbar CT Supervision relay.

The modification for GT-1 & GT-4 in differential relay CT Circuit for RMU-1 & RMU-2.

The interfacing between fire alarm system and each power transformer control panel also for common alarm system.

The proposal of NSD panels location in the telecom room at remote end Substations 8047S/S

& S/S 8012 (PP-5) to take approval from SEC.

The proposal of the front view for the relay panels at remote end Substations for the location of the main relay.

132 KV Relay Panels and Control Panels functional Check.

Review SCADA Point List as per the schematic drawing.

The interfacing between each 132 KV feeder protection panels and NSD panels.

Power Transformers TRMK panel functional check.

Fault recorder DC and AC functional check.

The interfacing between relay panel and NSD panel at the remote end substations.

The modification of SCADA point List for remote end substations. From 2009 June to 2010 March 2010

Project: Power factor Improvement

Post : Testing & Protection Engineer

At S/S No. 8106, Quortoba, Riyadh Area

Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(Merlin Grain Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

On Load Test after energization with SEC Witness Engr. At S/S No. 8040, Al-Orija’a, Riyadh Area

Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(Merlin Grain Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

On Load Test after energization with SEC Witness Engr. At S/S No. 8078, Al-Dera’ea, Riyadh Area

Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(ABB Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

Outdoor CT’s Test with SEC Witness Engr.

Outdoor VT’s test with SEC Witness Engr.

Outdoor Capacitor and Reactor Test with SEC Witness Engr.

13.8 KV SWGR capacitor bank feeder functional Test with SEC Witness Engr.

13.8 KV Surge Arresters Test with SEC Witness Engr. At S/S No. 8066, Al-shifa’a Riyadh Area

Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(ABB Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

13.8 KV SWGR capacitor bank feeder functional Test with SEC Witness Engr.

13.8 KV Auxiliary relays Test with SEC Witness Engr.

13.8 KV Surge Arresters Test with SEC Witness Engr. At S/S No. 8041, Al-Orija’a, Riyadh Area

Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(Merlin Grain Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

On Load Test after Energization with SEC Witness Engr. At S/S No. 8049, National Guard Compound, Riyadh Area Responsibilities:

Modification for the existing feeder which will be replaced because the old 13.8 KV Breaker

(Merlin Grain Make) it was Vacuum type with one Trip Circuit then modified with new 13.8 KV SF6 Breaker type with two trip Circuit.

The interfacing between 13.8 KV SWGR and new relay panels for tripping circuit.

The interfacing between 13.8 KV SWGR and ACCS Capacitor Bank Control panel for the alarm and binary input to PLC.

Modification in Stuck Breaker and Busbar Protection for the new 13.8 KV SWGR panels under load without shutdown with SEC Witness Engr.

Relay Panels and control Panel Functional test with SEC Witness Engr.

SCADA Point List Updating with SEC Witness Engr.

SCADA Final Commissioning with SEC Witness Engr. With master Station.

Final Trip Test with SEC Witness Engr.

13.8 KV VT Circuit Test.

On Load Test after Energization with SEC Witness Engr. From 2007 July to 2009 May

Project: Construction of New S/S 8118 AL-Nazeem, Riyadh Area Post : Testing & Protection Engineer

Responsibilities:

13.8 KV Over Current relay (GE, MIF III) for all panels Testing and final setting with SEC Witness Engr.

ACSE Panel function check with SEC Witness Engineer.

Final Trip Test at the remote end substation No. 9015 for our circuit which one connected to 8118 S/S with SEC Witness Engr.

SCADA Test with SEC Witness Engr. And With master Station.

End to End Test with SEC Witness Engr.

On Load test after energization for Circuit No. 9015 with SEC Witness Engr.

On Load End to End Test with SEC Witness Engr.

From 2006 March to 2007 May

Project: Construction of New S/S 8129, Ghurnattah, Riyadh Area Post : Testing & Protection Engineer

Responsibilities:

MV Switchgear functional test.

132 KV GIS Timing Test with SEC Witness Engr.

132 KV GIS gauges and C.B gauge calibration Test with SEC Witness Engineer.

SF6 Gas Dew Point Test for 132 KV GIS Compartments with SEC Witness Engr.

132 KV LCC Panels functional Test with SEC witness Engineer.

132 KV VT Circuits Test with SEC witness Engineer.

Control Panel and relay Panels functional Test.

Control Panels and AC/DC Panels Meters Test With SEC Witness Engineer.

MCCB’s and MCB’s test with SEC witness Engineer.

132 KV LCC Panels Annunciators Test and Setting with SEC witness Engineer.

13.8 KV Power Cable HV Test by Very low frequency equipment with SEC Witness Engr.

132/13.8 KV Power Transformer local control panel function check test with SEC Witness Engr.

From 2005 November to 2006 March

Project: Construction of New S/S 8097, Al-Aqeeq, Riyadh Area Post : Testing & Protection Engineer

Responsibilities:

13.8 KV Power Cable HV Test by Very low frequency equipment with SEC Witness Engr.

132 KV VT Circuits Test with SEC Witness Engr.

Pre-check for 132 KV LCC Panels.

MCB’s Test.

132 KV GIS LCC Panels functional check test with SEC witness Engineer. EXPERIENCE IN EGYPT:

Company Name: Al-Sharqiah Thread Waving Company, Zagazig City-Egypt. From January 2004 to July 2004

Post : Electrical Engineer

Responsibilities:

Handle all Electrical Maintenance activities.

- Training courses

1- Training in ABB Electrical industries CO., in 10 th

Ramadan industrial city, Egypt about

Distribution Transformers design and commissioning, Earth fault detector test, Battery Chargers, MV Switchgear Breakers design and commissioning from 1/7/2001 to 1/8/2001. 2- Training in North Cairo Electricity Production Company, Egypt about Generation systems and Protection from 15/7/2002 to 25/8/2002.

3-Training in ABB High Voltage industries CO., in 10 th

Ramadan industries City, Egypt about

Outdoor VT, CT and Surge Arresters design and Commissioning from 25/6/2003 to 24/7/2003. 4- Training in Technology and information center related to Telecommunication Ministry in Egypt about Computer Courses.

Skills

1. Language skills: -

1- Arabic: - Mother language

2- English: - Very Good

2. Computer skills :-

1- Windows XP.

2- Excel & Power Point.

3- MS project and Planning.

4- C++ and Visual C

5- Mat lab.

6- Fuzzy Logic Applications.

3. Testing Equipment’s Skills:

Omicron CPC-100, Omicron CMC-156, Omicron CMC 256, FREJA 300, SVERKER 760 ISA ART3, Low Frequency High Voltage Equipment’s, KOKOS (CB Analyzer). Other Skills:

* Hathaway Computer Software using (fault recorder), DIGSI 4.7 Siemens.

* ABB RTU, Harris GE RTU and Microsol RTU all of them for SCADA.

* AutoCAD 2015.