QA/QC
BAZEMLAL SAID
First name: SAID
Last name: BAZEMLAL
Date and place of birth: 09/01/1975 - BENI-ISGUEN-GHARDAIA
Address: *** ********* ******** ***** ********* Algeria
Nationality: Algerian
Family Situation: Married (03) Daughter
Driving license: Category B
Mobil no: +213-***-***-***
WhatsApp +1-514-***-****
Email: ****.********@*****.***
Professional Summary:
Certified Welding/NDT professional QC with more than 15 years’ experience in Oil and Gas field.
Brave and Proficient QA/QC in PQR, WQT, NDT and mechanical testing.
Quality control in welding: for carbon steel, stainless steel or allow steel in work shop and
Field joint, coating, branch connection, pipeline, Tie-in spools, tank, above ground and underground
Installation, flow line and export line.
QA/QC in pressure testing of pipeline; piping installation with required document (test package)
As per stander’s and specification.
Job objective:
The aim is to have a progression for the CWB welding inspector level 2 and this according to the position of welding inspector level 1 that I will occupy within your company
Educational Qualification
- 1994-Completed High School Education Degree in natural sciences. - 1994-1995 First year universities in exact sciences technology.
- Nov,14th –Nov,24th 2022 Training course for welding inspector level 1 CSA W178.2 Level 1
Technical Qualifications
-Feb 2023 Certified Welding Inspector CWB CSA W178.2 Level 1,ASME B31.3 endorsement ID: 5006737
-2017 Certification MT level II SNT-TC-1A.
-2017 Certification UT level II SNT-TC-1A.
-2016 Certification PT level II SNT-TC-1A.
-2016 Certification RT level II SNT-TC-1A.
-2013 Certification PT level II SNT-TC-1A.
-2013 Certification RT level II SNT-TC-1A.
-2012 Attestation of Radioprotection.
-2004 Certification RT level II SNT-TC-1A.
-2004 Certification PT level II SNT-TC-1A.
-2001-2002 Polyvalent NDT inspector level1 RT; PT; UT; MT; VT. -
Recommendation
-10/04/2011: Recommendation letter from UTE ABENER (FEDIRECO SANDOVAL) construction manager.
-31/08/2019: Recommendation letter from GS E & C DAELIM (Y.M.SHIN) Site manager.
Work experience: (2002-2023)
-Feb 2019-Feb 2023: WELDING INSPECTOR IN GS E&C DAELIM
- QA/QC ENGINEER LEVEL 2 PIPING, WELDING & MICHANICAL INSPECTOR WITH GS E&C DAELIM-Power plant with cycle combined KAIS (GE – CEEG -SONELGAZ)
-Jul 2016- Feb 2019: WELDING SUPERVISOR IN ENTREPOSE ALGERIA GROUP VINCI
-NDT inspector QA/QC level 2 with ENTREPOSE ALGERIA GROUP VINCI- Boosting LDBP4 & GAS LIFT HASSI MESSAOUD (-JGC- SONATRACH)
-Water Injection Pipeline project ROOM-BRN (AGIP-SONATRACH).
- SOUTH SATELLITE REVAMPING PROJECT (JGC-SONATRACH).
-Oct 2004 - Feb 2016: NDT Inspector in the society WELDTEST on plans:
-Feb 2014- Jan 2016: NDT inspector QA/QC level 2 Power plant 590MW HASSI R’MEL (ENTREPOSE-METKA-GE)
-Jan 2013- Jan 2014: NDT inspector QA/QC level 2 Gathering and gas treatment plan in IN SALAH Site – REG - (PETROFAC - ISG – SONATRACH).
NDT inspector QA/QC level 2 Gathering and gas treatment plan in IN AMINAS ZERZAITINE (SONATRACH – SINOPEC).
NDT inspector QA/QC level 2 Gathering and gas treatment plan in IN SALAH - HASI-MOUMENE (BONATTI–PETROFAC-ISG).
Dec2011 – Nov2012:Quality control inspector QA / QC level 2 Gathering and gas Treatment plan in GASSI TOUIL (BONATTI–JGC–SONATRACH)
Sep 2009 – Oct 2011:Quality control inspector QA/QC level 2 Power plant of exchange crosses150MW Including tow Boilers, gas turbine, steam turbine and tow champs solar
(UTE ABENER) HASSI R' MEL.
Jul 2007-Aug 2009:- Quality control inspector QA /QC level 2 Gathering and gas treatment plan. - Quality control inspector QA /QC level 2 shutdown 15 days in 2007
(GROUPEMENT TFT: SONATRACH, TOTAL, REPSOL)
May2006-June 2007: - inspector level 2 Power plant of BERROUAGHIA
(SAIPEM, SIMENS, SDEM, SECOMOC France)
- Inspector level 2 electric central plan of MECHERIA (ETTERKIB, SONELGAZ)
Mar 2005-Apr 2006:- inspector level 2 Helium recovery young plant (ETTERKIB, LINDY) SKIKDA
- Inspector level 2 Power plant with cycle combined by SKIKDA (SNC LAVALIN, ETTERKIB, LEAD, BENTINI)
- NDT inspector - station of recuperate associated gas. Sit of HASSI R' MEL (NOUVOPGNONE)
Oct 2004-Jan 2005: - NDT inspector-LT Flare project-on the site of
HBNS HASSI BERKINE (ANADARKO)
-NDT inspector centre enfûteur NAFTAL ARZEW (ANTRABELGE)
-NDT inspector thermal Power plant of MERSA EL HADJADJ (ETTERKIB, ANSALDO-
-Oct 2002 – Dec 2003: Welding Inspector Level 1 in ENGTP on plans:
- Welding & NDT inspector in EN GTP - INSALAH GAS PROJECT- in HASSI R' MEL (JK) In the fabrication shop assisting and inspection of a deferent welding process (SAW-GMAW-FCAW- GTAW-SMAW)
- Welding & NDT inspector in EN GTP - INSALAH GAS PROJECT- in INSALAH (JK)
Skills:
- Mastery in GE MLI gas turbine.
-shutdown 15 days in 2007
-Qualification of welding procedures, and approval of the welders in various plans
- welding inspection while the construction of deferent plans
- Document control (PQR, WPS, PIP Book, Examination Reports and preparation of test pack) - Verification of Isometric as built and checking of punch list.
-Reporting of all inspection activities (welding, NDT and NDE) - Reading films of radiographic testing
- Interpretation the resultants of dye liquid penetrate.
-sandblasting & Painting Inspection.
-Assistance of Holiday test.
-Preparation and conduct of hydrostatic testing: PIPLINE, PIPING and EQUIPMENT
-Good application of the international code (ASME IX; ASME V; ASME B31.3; ASME XIII) And API 1104 and DNV-OS- F101
-Monitoring all Quality Information in the WMS or DMS (welding or document management system) -Assistance mechanical test for welded joints (bend test and tensile test).
-Mechanical Inspection of steel structure (verticality and bolt tightening).
-Mechanical Inspection of static equipment (vessel; Drum; HRSG Module; Air duct).
-Reading blueprint drawing.
- Mechanical Inspection of rotate equipment (Pomp; Generator; Hoist crane).
- Thickness check by ultrasonic testing (corrosion test).
Computer Tools: Windows, WinWord, Excel XP.
Language: French, English, Arabic