VETRI RAJAMANICKAM
Avvai nagar, choolaimedu Chennai Tamil nadu India
Mobile: +91-733*******,+965-********(Whatsapp) Email: adwuc9@r.postjobfree.com
Career Objective
“I am seeking an opportunity to merge my initiative, enthusiasm, and 15 years of proficiency to add value, both to the organization and myself. I aim at expanding my horizons and developing skills in the Maintenance Engineer- Electrical to work in a dynamic environment, which provides opportunities for my growth.” Maintenance Oil and Gas Refinery, Railway Projects, and Petrochemical Industries.
S.no
Company Name
Project Name
Position
Duration
1
M/s.Alghanim International General Trading & Contracting Co-Kuwait
KOC Water Knockout Project-4082 under the contract number-17051670
Commissioning and Maintenance of Electrical Equipments such as Breaker, MCCB,Panel Modules,UPS,Battery Charger, Battery and Generator, Transformer
Commissioning Engineer -Electrical
Dec-2021
to Present
2
M/s. Petrofac international limited(Rajasthan-Barmer)
Integrated Gas Development Projects- Commissioning and Maintenance of Electrical Equipments such as Breaker, MCCB,Panel Modules,UPS,Battery Charger,Battery and Generator,Transformer and Overall
incharge of Electrician, Technician A/C Mechanic and Plumbers.
Lead Commissioning and Maintenance Engineer
June 2020 to Feb- 2021
3
M/s. Petrofac international limited(Kuwait)
KOC New Gathering Centre
GC-29 Phase-2- North Kuwait
KOC Approved Commissioning and Maintenance Engineer
Mar 2017
to Mar 2019
4
M/s. Larsen and toubro limited,(Qatar)
Doha Metro Project-Qatar
Maintenance Engineer
Jul 2015
to
Jan 2017
5
M/s.Voltech engineers pvt ltd-international location (Qatar, UAE)
Larsen and Toubro limited (PT&D)-Kahramaa Power and water authority
SPIE -Oil & Gas UAE
Maintenance Engineer
May 2012
to
April 2015
6
M/s.Voltech engineers pvtltd-domestic location (India)
1.Cairn Energy India Limited (CEIL) through M/s L&T
2.Mangalore Refinery and petrochemical limited (MRPL) Through M/s L&T
3.Indian oil corporation limited (Vadodara-Gujarat) Through M/S VEPL 4.Indian oil corporation limited (Mathura-UP)
Indian oil corporation limited (Panipat)
Commissioning Engineer
Aug 2008
to
April 2012
Resume of VETRI.R 1 P a g e
Having a good experience and knowledge in projects, Maintenance, Testing and Commissioning of Railways, power plant, substation and process plant.
Successfully Completed ETAP (ETAP 115 Power System Analysis) training from ETAP Automation Pvt Ltd.
Successfully Completed Electrical Design and Detailed Engineering
Area of Interest
400,220,132KV Switch yards
Protection relays testingfor
LV & MV Motors,VSDtesting
Equipment testing and
Incomers feeder,
and pre-commissioning
functional check
Transformerfeeder,motorsfee
activities and solo run test
der for All make
,load test (upto 2000KW)
400V to 33KV Switchgear
Equipment testing and
Power Transformer testing
Pre-Commissioning
functional check
with RTCC/OLTC and stability
andvendor coordinationFor
test (up to 315MVA)
DCS,SCS& SCADA (DI&DO)
11KV RMU & 22KVRMGGas
insulated switchgear
Battery and UPS systems Pre-
High voltage test (hipot) for
Equipment testing and
Commissioning and vendor
Cable, breaker, bus bar
functional check
coordination
Upto33KV
Operation & maintenance of electrical Equipment’s in Main Substation, Sub-Centre& Trouble shooting of Electrical equipment’s in Process plants
Operation & maintenance of Switchgear’s 33KV, 11KV, 6.6 KV, 3.3 KV, 440V
Functional test of HT and LT Switchgears such as Power & Distribution Transformers and Motors
Operation & maintenance& Trouble Shooting of UPS Systems Up to 40KVA - 415V/ 230V AC, 110VAC
Preventive maintenance of the UPS batteries, Switchgear, MCC, Motors.
Preparation & Updating of Maintenance Schedule for Preventive Maintenance of all electrical Motors
Preparation and Updating of Daily, Weekly, Monthly Reports for Breakdown
Conditional Monitoring of Switchgears, Transformers & Motors
Operation & maintenance of Lighting System, Photocell, Timer Controls, Fire Alarm System, Extinguishing Systems with Smoke & Heat Detectors, EOT crane Control System
Following Work Permit System with Job Safety Analysis Worksheet in Plant and field environments
Checking and Upgrading the Single Line, Three Line Schematic and Control Drawings
Handling of BDV test, Oil Purification for Transformer RTCC, OLTC, MOG, OTI, WTI, PRV Control Circuits
Electrical panel management for Machines & utilities to minimize the break down time
HVAC System and Mechanical related such as Fire Fighting system, PAGA, MEP related activities.
Preventive & predictive maintenance of production machines and its documentations
Planned Maintenance Schedule and timely attendance to Breakdown.
ERP system for various Maintenance & Spares procurement activities.
Complaint management system for internal customers and take of corrective action with in time.
Preparation of Maintenance Schedule
Coordinating with Testing Engineers, Manufacturer, OEM, and Vendor, QA/QC,
Coordinating with Consultant and Clients
Preparation and implementation of Field Change Request and SOP/SMPs (Standard Operating
/Maintenance Procedures).
Red Mark-Up drawings verification
Preparation of MR and EMR
Preparation of Maintenance schedule plan
Attending Progress Meeting & Site related issue
Coordinating Design related issues and Identify & develop alternate vendors for repairs other than OEM
Nature of work
Operation & maintenanceof all Electrical equipment from 415 volts to 765 KV (AIS & GIS) System,
Testing, Diff Stability and REF Stability of Power Transformer (100MVA).
Operation & maintenanceof Motors (2000KW), L.T, MV, and H.T Switchgears, Switchyard (CT, CVT, CB, Busbar, Disconnector, and Earth switch).
Testing and commissioning of Control & Protection panel and Protective Relays (Numerical- Areva, ABB, Siemens and, Electromagnetic) for
Transformer, Generator, and Motor Protection relays (Differential, over current & Earth fault, REF and Stability and schemes.
Feeder Protection and Busbar Stability with Bus transfer scheme
Inspection of control and relay panel, preparation of Test Report, cable schedule, As built Drawings, Method of statement for shutdown jobs and Operation & Maintenance for sub- station, power plant, and process plant.
Switchgears
Switchgears ratings up to 380KV,132KV,33KV,11KV,13.8KV,415V ABB, Hyundai, Schneider,132KV Control Wiring Modification with New System
Medium Voltage & Low Voltage-Isolated Phase Bus duct, Non-Segregated Phase bus duct, Busbar Contact Resistance Test, IR Test, Torque check, AC High-Pot test, Current/Voltage Transformer IR, Winding Resistance Test, Ratio Check, Saturation test, Flick On Test
HV, MV and LV Circuit Breaker IR, Contact Resistance Test, Breaker Timing Test, High-Pot Test
Checking and Testing the Interlock Intertrip Systems between Up and Down Stream Breakers, Earthing Interlock Systems for Busbar & Feeders, Transformer, Motor Feeders 380KV,132KV,33KV,11KV,13.8KV,415V Systems
Functional test of Extra High Voltage, Medium Voltage, Low Voltage Switchgears, Circuit breakers, Transformers and Motors
Functional Test of High-Speed Bus Transfer System, Auto Transfer Schemes
Testing and Calibration, Trouble Shooting, Protective Relays, Transformer, Motor, Over Current and Ground Fault Relays, Under/Over Voltage Relay, Motor Protection Relays, Protective Relays, Preparation and Updating of Relay data sheet. Transformers Stability, Sensitivity and REF
Checking and Upgrading the Single Line, Three Line Schematic and Control Drawings for the Extra High Voltage, Medium Voltage, Low Voltage Switchgears, Generator Protection Control Panels, GIS Interface Panels, MCC& PMCC Panels,
Preparation and updating the Final as built drawings, Test Reports, Training Manuals
Transformers
Power Transformers, Auxiliary Transformers, Distribution Transformers with Two &Three winding rating up to 60MVA and Dry type Transformers-ABB, Hyundai
Factory Acceptance Test activities for Medium and Low Voltage Transformers
Transformers -IR Test, Polarization Index Test, Turns Ratio Test, Vector Group test, Oil BDV Test, Winding Resistance Test, PRV, MOG, ExcitationTest, Tan-Delta Test and Transformer Functional Check
Functional Test of OLTC with Automatic Voltage Regulator Panels,
VSD Drives & UPS
Maintenance and Troubleshooting of ABB make ACS-1000 Variable Speed Drive in Crude Export
Maintenance and Troubleshooting of Nidec make Variable Speed Drive in TV compressor
Maintenance and Troubleshooting of Nidec make Variable Speed Drive in Heater Blower’s
Maintenance and Troubleshooting of CEG make UPS and Battery charger with Battery
Maintenance and Troubleshooting of Shaft make UPS and Battery charger with Battery
Maintenance of Electrical Equipment’s (Power Transformers, Generators, Motors, CT, and CB, Disconnections, Earth switches and Protective Relays).
Scheme checks and Relay co-ordination as per specification.
Preparation of safety documents and method of statements for outages.
Preparation of as built drawings, cable schedule and Site acceptance test records according to the specifications.
Trouble shooting of all Electrical control and protection circuits.
Co-ordination of SCADA.
MiCOM P632 - Transformer Protection MiCOM P120, P127, P143, P142 - O/C & E/F Protection
MiCOM P220, P242 –P141 - Motor protection & Motor differential CDG, CAG - Current operated relays
MVAJ, MVAX, MVTT, MVT - Voltage Operated relays
RET 670 - Transformer Diff.Protection.
SPAJ, REF541 - O/C & E/F Protection.
SPAM and REM - Motor protection.
SPAU - U/V and O/V relay.
SPAJ 115c - SEF and REF.
REL 670 - Distance protection relay
REF-615 - Feeder Protection relay
REM-615 - Motor Protection relay
T-series- T/F - Protection
M-series - Motor protection
7SJ6005, 7SJ6225 - O/C & E/F Protection.
7UT612 - Transformer Diff.Protection.
7SJ62, 63,64 - Multi function Relay
SEL 751 A - O/C & E/F Protection.
M-comp - Motor Protection relay
Bachelor of Electrical & Sapthagiri college of Engineering (ANNA UNIVERSITY) 2008 78%
Electronics Engineering (Tamil Nadu)
Office Packages MS-Office
Operating Systems Windows XP, 7, 8
Name
VETRI.R
Languages
Tamil, English, Hindi
Father’s Name
RAJAMANICKAM.K
Date of Birth
09.05.1986
Sex
Male
Marital Status
Married
Nationality
Indian
Passport No
N2955829
Age
36
Native Place
CHIDAMBARAM
Declaration
I hereby declare that the above information given by me is true to the best of my knowledge. Place: Yours Sincerely,
Date: (R.VETRI)
Technical Skills
Personal Details