Post Job Free

Resume

Sign in

Electrical Engineer Quality

Location:
New Delhi, Delhi, India
Posted:
April 28, 2023

Contact this candidate

Resume:

BINAY KUMAR

Mobile: +91-748*******

Email: adws1f@r.postjobfree.com

Contact add: Madhu vihar Delhi

CAREER OBJECTIVE

Electrical Engineer with 12.5 years’ Experience in successfully handle Electrical, Utility, MEP & infra project with Quality including Equipment Load calculation, project management, project coordination, site execution and erection as Transformer, all Electrical panel, APFC panel Circuit breaker, Earth pit, Diesel Generator, fire Fighting, Fire detector system, HVAC, STP, WTP, Metro rail, Airport, single line diagram, AUTOCAD, Cable, Oil & gas, Ups, battery bank & solar panel.

ACADEMICS

Completed B.E ELCTRICAL ENGINEER from SSBTCOET BAMNHORI JALGAON affiliated to NORTH MAHARASTRA UNIVERSITY JALGAON and achieved 67% (2010).

Completed Intermediate from B.I.E.C PATNA BIHAR with 61.5%.

Schooling from B.S.E.B PATNA BIHAR with 53.5%

PROFESSIONAL EXPERIENCE:

SR UTILITY ENGINEER AT SYSTEMATIC CONSCOM LTD (MOTHERSON GROUP) Oct-2021 to till now

Responsible of Project Execution, Erection, commissioning Green, Brown & Maintenance project & successfully hand over the project with Quality.

Review all MEP drawing as site plan & start the construction & installation Activity.

Erection, connection & testing of transformer, Vacuum circuit breaker & RTTC, All Electrical, Main panel, PBD, MCC, Lighting, Ups, AMF, DG synchronization & Air compressor panel.

Erection, Connection and testing of all Circuit Breaker Breaker, & distribution Board Dressing, Connection & thimble of all cable in circuit breaker (MCB, MCCB, RCCB & ELCB)

Erection of bus duct, HT & LT cable laying underground, overhead & Hume pipe.

Evacuation work and testing of plate, pipe & chemical earth pit & GI strip/Cable size connection of earthing all equipment as per fault current

Preparing drawing, Installation & Pressure testing & follow NFPA guideline, firefighting work, fire curtain system, hydrant line, sprinkler pipe line & all pump

Preparing drawing & installation as per NFPA Guideline & testing of addressable & conventional smoke, heat & beam detector & fire panel, hooter, MCP & control modules & response indicator.

Erection & testing of AHU, Air washer, cooler, FCU, TFA, VAV, VRV/VRF, indoor, outdoor unit, duct, CO2 sensor, CFM testing, as per CFM value duct size installation, pump, chiller pipe with insulation, Temp gauge, pressure gauge, differential pressure switch, &cooling tower.

Installation of Duct, insulation, sound acoustic, VCD, damper, motorize damper, motorize fire damper & axial fan.

Check as per drawing & Erection of mains (RAW) & Ups power lighting, street light, Highway light & power socket installation, cable routing, termination & connections.

As per drawing Installation of workstation raceway & power cable routing & connections.

Calculation of cable tray size & Installation of raceway, perforated & ladder type cable tray.

Erection & testing of STP & WTP plant pump, flite (ACF, DMF) & membrane RO.

Erection & testing of PA system & amplifier.

Installation of lighting protection & earthing grid.

Good knowledge of load calculation of transformer, HT, LT cable, circuit breaker, Ups, battery, DG, AC, Cable tray, Earth pit & all electrical material.

Attending inspection of project schedule plan and as per testing and commissioning.

Planning to evacuation work, Safety & Attending on daily basis meeting with contractor and preparing MOM.

Completed the project on time with MOM & timely handover the document to the plant/client.

Review and analysis all Utility/MEP drawing, BOQ material schedule of work.

Daily review meeting to contractor’s team all work should be done as per drawing & Quality

All activity completed during the fixed period of time. PROJECT ENGINEER AT LAKSHYA GLOBAL SOLUTION

Aug-2019 to Oct-2021

Responsible and monitoring of all electrical related work at site & successfully handle of Project.

Load calculation of all HT /LT equipment’s as transformer, RTTC panel, VCB, Cable, UPS, battery & earth pit

Good knowledge in MEP/ electrical installation & testing of transformer, Vacume circuit breaker, panels, DG, DG panel & lighting.

Cable laying HT & LT underground, overhead power cable.

Preparing drawing as per site condition & evacuation work firefighting, fire detection system, cable tray, CCTV & lighting protection .

Review & analysis of daily progress report, final bill coordination with site Engineer.

Erection & testing of power plant, battery bank, power interface unit & servo stabilizer

Maintaining work and follow quality in Civil, Mechanical & Electrical Work across the region, timely execution of site work and delivery of site to customer proper documentation.

Responsible of Tower foundation civil work pile, raft, tower bolts slab Casting, DG slab casting, solar stand casting,

Expertise of technical training, problem solving and safety training.

Follow guideline specified by the client & Progress report on daily basis. QUALITY AUSTRIA CENTRAL ASIA PVT.LTD:

I worked in this company Quality Austria Central Asia from Aug-2014 to July -2019 As a Sr Electrical Engineer. Successfully installation, testing & inspection of quality:

Inspection of erection, connection & testing report of transformers, VCB, Bus duct, HT, LT, Main panel, MCC, APFC panel, DG & DG panel.

Inspection of H.T and L.T Power Cables routing, overhead and underground cable, Instrumentation Cable & Control Cable.

As per order/drawing installation & connection check Circuit Breaker MCB, MCCB, ELCV & RCCB & also as per site load all breaker.

Quality testing of solar panel, on grid, inverter, battery, AC distribution box, surge protection device, proper wiring, grounding & load calculation ac & DC cables.

Inspection of HVAC work, indoor & outdoor unit, AHU, chiller, chiller pipe line, duct installation, duct installation, acoustic, VCD, collar damper, fire damper, VAV, grill & CFM testing.

Inspection, installation & testing of firefighting work, as per order check pump make and capacity, hydrant line, Sprinkler branch pipe, raiser, pipe support testing & leakage.

Good knowledge of short circuit calculation, voltage drop calculation and check Phase Load balancing earthing strip.

Quality check third party inspection Metro & Airport project electrical as LT, HT panel, circuit breaker, cable routing, Earthing, GI strip, lighting arrester, illumination, bus bar& panel (PCC panel, AMF panel & DG synchronization panel)

Installation check Bus bar, lighting arrester, Cable tray, & cable routing, roof, wall mount, cable tray calculation bend 90 & 45 degree & conduct pipe.

Inspection installation & Testing of SMPS, Battery bank, Capacitors bank, inverter, Cables, power plant, Diesel Generator, AVR panel, AMF, & power interface unit & servo transformers.

Check the installation & testing of fire panel (addressable and conventional) smoke detector, heat detector, beam detector, hooter & FM-200

Evacuation work and testing of plate, pipe & chemical earth pit & GI strip/Cable size connection.

Good knowledge of drawing and verifying material & quantities.

As per drawing installed, tower, pole and minor casting civil work.

Third party Quality check as BPCL oil & gas,

As per work measurement bill check and sign.

Obey all safety rules fallow and maintained cleanliness of work area RAMBOLL INDIA PVT LTD.

I worked in this company “RAMBOLL INDIA PVT LTD” from NOV-2010 to AUG-2014 as a “ELECTRICAL Quality Engineer”

Duties & Responsibilities.

Erection & quality testing report of Transformers, all panel, Earth pit (plate, pipe & chemical earthing) circuit breaker, distribution board, laying of HT, LT cables and all Electrical equipment’s

Erection as per drawing & testing of AHU, installation duct, VCD and CFM value.

Erection as per drawing & pressure testing of firefighting, pump make & capacity, sprinkler & hydrant line, fire detection system

Check As per order material make & capacity installation at site & sign of measurement sheet.

Check equipment selection size & protection, Circuit breaker, transformers, cable sizing, duct fire fight pipe, cable tray, capacitors bank & DG, earth pit, battery & UPS.

Erection & quality testing report of SMPS, battery bank, PIU & rectifier modules.

Evacuation work and testing of plate, pipe & chemical earth pit & Earthing cable & GI strip Routing.

Installation check lighting arrester & earthing grid.

Knowledge of Autocad, single line diagram

PROFESSIONAL QUALIFICATION.

Personal Training In Electrical Locomotive Workshop BHUSAWAL On Transformer Winding, Motor Winding, Compressor Winding, Welding, Servicing of Emu Loco & Electric Loco.

Khadka Substation BHUSAWAL Introducing a Station, Control Room Operation, Coal Yard, Boiler and Distribution.

15 Days Training for Supervisory Control and Data Acquisition (S.C.A.D.A) Introducing a Station to a system for remote monitoring and control that operates with coded signals over communication channels.

One day Training for VIP Private Ltd NASHIK Introducing manufacturing & quality.

Seminar topic Extra High Voltage AC Transmission line. PROFESSIONAL CERTIFICATES.

Auto CAD from “All India Institute of self- Government PUNE”

Single Electrical line diagram

KEY SKILLS

Microsoft excel, MS office & power point

PERSONAL INFORMATION:

Name : Binay kumar

Date of Birth : 08th May

Sex : Male

Father’s Name : Shree Kameshwar pd roy

Address : Delhi

DECLARATION:

I hereby declare that the details provided by me are true to the best of my knowledge. Date :

Place : [Binay kumar]



Contact this candidate