Post Job Free
Sign in

Electrical Engineer Qc Inspector

Location:
Iraq
Posted:
April 11, 2023

Contact this candidate

Resume:

Sebastian Eugen Manea

Electrical Engineer I&C Leader Commissioning – Precomm PM LOTO Inspection Maintenance – O&G, Energy, Industry

Nationality: Romanian Residence: Fetesti, Ialomita,Romania

Date of Birth:25.09. 1972 Other Citizenship: European

Native Language:Romanian Languages: English - Advanced

EDUCATION

Electrical Engineer

University Spiru-Haret, Brasov (From 01.10.2003 To 20.07.2006)

Quality Management

Specialization: Electrical.

College School of Informatics.(From19.09.1994 To 21.06.1996)

Specialization: Computer Analyst Operator.

Industrial High School of Automation and Electrical.(From 15.09.1988 To 15.07.1992)

Maintenance for Electrical Equipments.

+407******** +407********

*******@*****.*** linkedin.com/in/sebastian-eugen-manea-88321949/

Sebastian Eugen Manea

PROFESSIONAL PROFILE

Electrical Maintenance for Power Diesel Generators, Gas Turbine Generators (325Kv,400Kv,625Kv).

Safety awareness in all aspects of the my work. Strong leadership with interactive skills to coordinate and supervise different project phases. These include full Control logic design and implementation, pre-commissioning, commissioning, start-up and production support. Coordinate with Project Engineer and EPCM Construction Management Team to bring a coordinated approach to the overall project scope, quality, cost and schedule expectations. Ensure that planning of the project deliverables from Engineering and Contracts & Procurement is line with the construction sequence and further to the hand over sequence.

Experienced in PM creation and integration for a wide range of applications including DCS, ESD, SCADA and F&G systems.

Outstanding response and reaction under work pressure, highly motivated and fast learning. Eager to learn new skills and welcome new challenges. Good interaction skills at both subordinate, peer and management levels.

Excellent interaction skills to deal technically with construction, pre-commissioning/commissioning groups working closely with project team.

I lead the company electrical team in many projects during CONSTRUCTION, PRECOMMISSIONING, COMMISSIONING, from FEED to SHUT-DOWN, REVAMPING and START-UP the SISTEM, in accordance to the applicable codes/standards and the project specifications, within the project schedule, assigned budget and the safe framework focusing on project resource management, quality assurance and execution controls.

PROFESSIONAL EXPERIENCE:

Electrical Maintenance Engineer 11/2021-09/2022

NILVOSIM Co. (Maintenance and Operation Company)

Organize and co-ordinate in the most safe and efficient way the assignment of the electrical maintenance team to the operational tasks to be performed.

Maintenance and optimization of process control systems; examples: calibration, maintenance and installation of additional transmitters, control valves, sensor and gauges.

Troubleshot electrical and instrumentation maintenance issues; (example: locate fault in field circuit by disconnecting wires at module and field device, check device for ground, short circuit for proper mechanical and electrical operation).

Ensures that all maintenance and repairs to equipment are carried out in a safe and efficient manner and in strict compliance with company operating procedures and any relevant statutory legislation in order to maintain all such equipment in sound and safe operating condition.

Electrical Inspection Engineer 08/2021-10.2021

ISS International Spa. (Maintenance and Inspections)

Ensure that all work is in accordance with project specification.

Scoping and planning of work. Attend the coordination meeting of all aspects of disciplines in order to establish priority and safety issues.

Inspect all the electrical equipment like Gas Turbine Generators (3,25MVA; 2,6MW and 6,63MVA; 5,3MW)

Transformers (2,1mva-250kva), Motors ( 1000Hp-200Hp),Bus-Bar, Breakers, Switchboards, Cable Trays.

Collect all the data from the Info Sheets of team, make the Work Report, Spread Sheets.

Ensure that all documents and work reports, as provided in the contract or required according to company procedures are issued, up- dated and retained.

Electrical Engineer Inspections and Maintenance 12/2015 – 08/2021

NILVOSIM Co. (Maintenance Company, ROMANIA)

Developed, supported, and maintain Atlas Copco compressors control systems including configuration database, controller and operations descriptions, coding, display layouts, simulations, and hardware.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports(Tracking work orders; Scheduling Task; External Work Request) related to my field.

Troubleshot electrical and instrumentation maintenance issues; (example: locate fault in field circuit by disconnecting wires at module and field device, check device for ground, short circuit for proper mechanical and electrical operation).

Updated all electrical and instrumentation control system documentation that included cataloging, filing of maintenance service reports, review and evaluate equipment service reports as required to provide a preventative maintenance program.

Troubleshooting, loop tuning and calibration transmitters for pressure, temperature, flow and level transmitters using Fluke temperature calibrator, Fluke process calibrator, and HART Field communicator.

Maintenance and optimization of process control systems; examples: calibration, maintenance and installation of additional transmitters, control valves, sensor and gauges.

Electrical Engineer 05/2015 – 12/2015

DIETSMANN S.A. Qarmat Ali - Veolia Water Treatment Plant (North Rumailah IRAQ)

Maintenance Management / Reliability strategies development contracts covering the following Water flood Infrastructure – Five Cluster Pumping Stations (CPS). Qarmat Ali Water Treatment Plant (QAWTP) Veolia Water Treatment plant.

Electrical Precommissioning and Commissioning .

Ensure that all work is in accordance with project specification.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports(Tracking work orders; Scheduling Task; External Work Request) related to my field.

Scoping and planning of work. Attend the coordination meeting of all aspects of disciplines in order to establish priority and safety issues.

Ensure that all documents and work reports, as provided in the contract or required according to company procedures are issued, up- dated and retained.

Organize and co-ordinate in the most safe and efficient way the assignment of the electrical precommissioning and commissioning team to the operational tasks to be performed.

Monitor and inspect site Works being undertaken by the contractors and subcontractors and monitor overall progress. Oversee and inspect all electrical & instrumentation work and ensure that installation activities comply with contractual obligations and quality control standards. Follow-up with the contractor and support in coordinating with the utility authority regarding connections whenever required. Receive material inspection requests (MAS’s) from contractor, inspect electrical & instrumentation materials at site and sign off requests. Prepare and complete the necessary documentation prior to inspection of the Works and process accordingly following completion of the inspection. Check plant, equipment and materials delivered are as approved and are properly stored. Inspect the installation works of electrical items as per approved shop drawings such as - SLD, Load Schedule, cable schedule, General arrangement of Electrical Equipment’s layouts and details, Earthling and lightning layouts, Fire Alarm and Telecom Layouts, - P&ID,PLC/RTU/HMI panel GA/IA drawings, Control System Architecture, Instrument Schedules, Cause and Effect Schedules, Alarm and Trip List,I/O lists and DCS tag lists, Hook up drawings, Termination and Loop Drawings, JB schedules, FOC cabling drawings, etc. Inspect the site test as per approved operation and control philosophy, FDS, Control schematics etc, and as per the approved SAT procedures and testing and commissioning procedures and Plan. Ensure that safety critical aspects of the project are identified and actively addressed.

Understand and provide maintenance support roles of different contractors mobilized at Qarmat Ali and CPS’s.

Approach maintenance contractors to establish a good communication in order to understand the existing work flow (i.e. maintenance activities, breakdown response, etc).

Surveying their sites to identify electrical equipments and power supply cables that are in good working condition or need to be refurbished.

Check all equipments installed online or on pumps skids as per P&ID and indentify the missing ones or the one out of service.

Provide solution for protection of running equipments (i.e. high/low voltage, motor high temperature protection, ground protection, etc).

Check availability of Control System and Emergency Shutdown System or any other control or protective system installed on sites (local control panel).

Check availability of Electrical/Control System Maintenance Procedure and prepare them if are missing or not available.

Check availability of Electrical spare parts in the Workshop.

Maintenance Electrical Supervisor 02/2014 – 08/2014

BONATTI Spa. WEST QURNA 2-GTPP (West Qurna, IRAK)

Organizes and performs on site the maintenance operations which are placed under my responsibility on power station, substations, transformers, electrical engines and spinning machines.

Maintenance on 400 kv power station equipped with GIS switchgear system, 33kv and 11kv substation.

Ensure good working of protection equipments (relay, contactor...).

Realize isolating controls (wires, engines).

Ensure the cleanness of electrical offices and regularly verify the security equipments.

Realizes specific studies to change or modify systems or equipments.

With my teams assists specialists working under Specific Maintenance Contracts (SMC).

Ensures that the COMPANY’s HSE regulations are respected (especially procedures related to Work Permits), as well as approved operating procedures and standard industry practice during performance of maintenance operations placed under my responsibility.

Ensures that all maintenance and repairs to plant and equipment are carried out in a safe and efficient manner and in strict compliance with company operating procedures and any relevant statutory legislation in order to maintain all such equipment in sound and safe operating condition.

Manages interventions using the CMMS.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports related to my field.

Monitors the functioning of systems placed under my responsibility.

Ensures that the transfer of knowledge by mentoring occurs properly within my teams, and actively participates in this my self.

Carries out, at the Superintendent request, any intervention within my field of competence.

Takes in charge the systems under my responsibility in case of breakdown until correct operation status.

Ensuring the proper functioning of all electrical units in the facility.

Ensuring scheduled checks for spotting any malfunctions.

Appropriately using and handling of electrical testing and repair equipment.

Completing all tasks as assigned by the supervising manager and attending job training activities.

Maintaining records of all electrical inventories and placing orders for spare parts and equipment.

Keeping a log of electrical repair and maintenance works.

Coordinating work functions with co-workers and other organizational departments.

Following all safety norms and standard operating procedures of working.

Electrical QC Inspector 05/2013 – 08/2013

ROSETTI MARINO SPA; Offshore Oil Platforms (ITALY)

Inspection of electrical and instrumental works carried out on two oil platforms; Verifying, checking and inspecting instrument and electrical equipment, several types of cables, glands, electrical connections as per ATEX Certificate; Verifying, checking and inspecting several types of E&I devices such as: Pressure, Temperature and Level Transmitters, LV Motors, Control Valves (Pneumatic &Hydraulic type), etc. Performing different test such as line check &loop tests carried out by the Yard; Producing defects lists for Punch List Issues.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports(Tracking work orders;Scheduling Task;External Work Request) related to my field.

Electrical & Instrumentation Pre&Commissioning Supervisor 01/2012 – 01/2013

TECHINT CIMIMONTUBI; Gas to Liquids (GTL) Project - construction (Escravos, NIGERIA)

Ensure that all work is in accordance with project specification.

Scoping and planning of work. Attend the coordination meeting of all aspects of disciplines in order to establish priority and safety issues.

Ensure that all documents and work reports, as provided in the contract or required according to company procedures are issued, up- dated and retained.

Organize and co-ordinate in the safest and efficient way the assignment of the electrical & instrument Precomm-Comm team to the operational tasks to be performed.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports (Tracking work orders; Scheduling Task; External Work Request) related to my field.

Prepare all PTW (work permit) to my team for the areas where was required.

Continuity and resistance insulation (Megger) test for all electrical circuits.

Hi-Pot test (high potential injector test) for all medium cables.

Solo motor run test for all low and medium voltage motors, generators, compressors.

Loop test for all primary and secondary instrument cables.

Insulation resistances test for all the instrument, PA-GA (general public Address), fire and gas detectors and alarms.

Hart communicator test for calibration of temperature, pressure, flow, trip valves and transmitters.

Electrical Maintenance Supervisor 11/2010 – 01/2012

SAMSUNG; New units at Polyolefins Plant (Bourouge, UAE)

MAINTENANCE SPECIFIC ACTIVITIES:

Periodic control of motor (noise, temperature, start current, running current ).

Close supervision of the alarms occurring in during operation.

Function tests prior to disposal problems and design errors, construction – commissioning.

Signature and ensuring safe - protection work permits.

SPECIFIC ACTIVITIES OF GUARANTY PERIOD: Technical assistance and direct intervention (where applicable) on the system, on client request.

Enters intervention reports in the CMMS (including those concerning SMC) and writes the technical reports (Tracking work orders; Scheduling Task; External Work Request) related to my field.

Termination of all reviews for this reserve and confirmation from client.

Checking and commissioning of the latest support systems (barrier gate, "video surveillance system, antineutrino loud).

Electrical cubicle -11Kv-ABB - loop check, wire check, CT and VT check (burden, magnetizing, ratio, insulation resistance, winding resistance, inspections of the concordances between the drawing and the connection).

V-meter and A-meter metering, functional test with the auxiliary Supply; (No load) interlock test.

Mechanical and electrical functional test for breaker.

Contact resistance for bus-bar.

Primary injection to CT up to 1600 A.

High Pot-Test up to 22 Kv.

LV electrical cubicle – 0.4Kv - ABB - loop and wire check, metering, CT and VT (ratio, burden, magnetizing, insulation, winding) V-meter and A- meter metering, accuracy, thermal relay overload check (trip curve), primary and secondary injection, under voltage relay (27), syncro-relay (25), earth-fault (51), temperature sensor to transformer.

House load, parameter recording.

Safety conditions for electrical system in case of fault equipment (isolate from DCS system or in manual mode in local side) DC and AC supply watch.

Insulation, winding, phase rotation, start and running current after motors replacement, polarity index, Hydrogen level from battery room, cause of trip from N-DIN-Relay and REF 542, safety condition for outage (rack-out, tag-out, lock-out with PTW and isolate certificate.

Kept safety rules for electrical conditions.

ELECTRICAL FOREMAN 10/2006 – 05/2007

TECHINT CIMIMONTUBI; LNG Trains Contruction (Bonny Island, NIGERIA)

Construction activities: Construction of all electrical, instrument and control circuits.

Ensure that all work is in accordance with project specification.

Additional and field modifications as necessary.

Assurance permanently of power delivery, repair of deficient aerial and underground electrical network, replacement of the fixture units, assistance

electronics instruments, supervision of the power unit.

I have realized a network connection for 20 computers system, installing Hub’s, Switch’s, Network card’s, network printers and made the configuration for computers to working in this network.

I have checked the grounding for electrical system and equipment.

Executing the junction on the phones lines for the Fax machines.

Checking cable continuity and installing connectors.

Troubleshooting on photocopy machines, Fax machines and solving the problems using wiring diagrams, maps, instruction manual. Maintenance for medium voltage electrical engines, speed regulators, driving circuits (AC/DC) for medium power electro engines (variable frequency drivers), hardware equipment for industrial applications, I/O circuit, and protection circuits.

COURSES and TRAINING

Lock-Out Tag-Out – LOTO - Electrical Hazard Area Classification & Equipment Selection - Plant Electrical Equipment Designing & Sizing - Fire Fighting Principles & Tactics Practical - Cathodic Protection Basics - Programmable Logic Control Basics Atex Ex. - Confined Space - H2S Training Saving Procedure - HSE training

Computer Literacy

Operating Systems:,Windows 7;8 and 10,11.

GUI’s & Languages: MS Windows, MS Office, Power Point.



Contact this candidate