Post Job Free

Resume

Sign in

Electric Co Electrical

Location:
Denver, CO
Salary:
28-32
Posted:
February 16, 2023

Contact this candidate

Resume:

Louis Buenabenta, Jr.

**** *. ****** ***, *-***

Denver, Colorado 80231

Cell- 720-***-**** advd1v@r.postjobfree.com

Objective: A position with a company that is established and has stable employment and room for growth and family orientated.

•State of Colorado Dept. of Regulatory Agencies

division of professions and occupations.

•Fourth Year Apprentice Certified, APE #9931258.

Experience: Peak Elevator Co. 5405 W.56th Ave. Suite e, Arvada, Colorado 80002 From: Aug.2018- To: Nov.2021. I started working for Peak Aug. 5th,2020, doing electrical work for them. But within two months I was repairing the elevators by installing motors and pumps for brands such as Otis, Kone, Schindler, Montgomery, TKE and many older elevators. I even became familiar with Smartrise contollers and programing the system. I fixed many of the doors that needed new door operators, motors, door sensors, hoist motor encoders. I packed jacks and have removed and reinstalled new jacks. Ive done fire service on many different types of elevators, I, cleaned and painted pits and maintained cleanliness for the tops of elevators. I,started taking courses through Peak for elevator mechanic through the CET program and did recieve my state of colorado license as a Elevator Temporary Mechanic. But was unfortunately laid off due to the Corona Virus.The company experienced a 70% infection rate, so they send everyone home and I don’t know if I'll be called back to work.

Experience: Gaylord Electrical Co. 5750 Castle Creek Parkway North Drive, Suite 400 Indianapolis, Indiana 46250 From: Dec.2018- To: Aug.2019. I worked with Gaylor Electric running EMT and some RIGID piping for the new Amazon Building in Thornton, Colorado. I ran scissor lifts to run over head power and lighting for this massive distribution center. I installed transformers and disconnects for the lighting circuits and for the power circuits to run the conveyor machines. I assisted in the installation of 350 MCM and 500MCM for the main transformers and disconnects. Experience: AM/PM Electrical Co. P.O.Box 472647, Aurora,Colorado 80047 PH# 303-***-**** From: May2018-To: Dec.2018. I worked for AM/PM renovating a marijuana grow in Denver, Colorado. I ran EMT for all the new LED lighting and for the new power supply that was being phased out and upgraded. I installed and mounted new panels and panels for control lighting modules. I installed and wired new transformers for the new power panels we installed. I had three 1st & 2nd year apprentice under my supervision and was given the responsibility of assuring our work was NEC perfect. I was laid off due to lack of more work.

Experience: Premier Electrical Staffing Company, 7535 E. Hampden Ave, Suite 400 Denver, Colorado 80321. From: Feb.2018-To:May. 2018 . I have worked for Premier for more than six month’s off and on when I didn’t have work. Iam currently employed by this staffing firm. Iam currently working for Northern Electric Co. at Lockheed & Martin Space Facility, doing the wiring of a vacuum chamber for the testing of space equipment and machinery. Iam running Unistrut for wire racks and installing EMT, Rigid conduit and low voltage circuitry and three phase and four phase circuit’s as well. There is a lot of exsisting electrical power and circuits that Iam also trouble shooting to determine what need’s to be eliminated or re-routed to be used later in the build.

Experience: Skyline lighting & Electrical Company, 1980 S.Quebec St., Denver, Colorado 80231. From: Nov.2017- Feb.2018. I worked with Skyline installing electrical component’s in new and old refurbishment commercial buildings, big and some mid-sized which included the medical clinics for UCD-CU health, various medical marijuana grows and other commercial projects. I installed all the new upgraded service panels and disconnects, installed exterior and interior lighting controls, receptacles, etc. I have also done various types of trouble shooting for all aspects of the electrical installation’s of these project’s. I have also installed EMT conduit and some rigid conduit for lighting and power circuits along with a lot of MC cable. My resignation was due to a conflict of intrest due to harsh & vulgar attitudes from the owners brother and his disrespect to communicate.

Experience: JDE Electric Company,747 Sheridan Blvd., unit #2c, Lakewood, Colorado 80214 From: July 2017- Nov.2017. I worked with JDE, from ground up installing the services for two warehouses/offices. Installed the disconnect’s and CT can’s for these two buildings which installed 5” inch PVC and 5” inch RIGID for the primaries from the transformer’s. I also installed EMT conduit for the secondary feeders for the sub-panels in each of the two buildings. I also did some trouble shooting to determine whether the exsisting power was useable or if needed to be demoed. I ran 3/4”inch and 1”inch EMT for lighting and power circuits and MC cable as well. I had 3-4 apprentice’s under my supervision at any given time. I resigned my position due to a conflict of interest’s with some temp hires trying to apply pressure to myself and other individuals to turn that job site into a Union ran job site.

Experience: K&B Electric Company, 2435 W. Industrial park Dr., Atlanta, Georgia 98076 From: Nov.2016- June 2017. With this company, I assisted K&B Electric with the refurbishment of the Crown Plaza Hotel in Downtown Denver, Colorado. I installed all sizes of E.M.T. conduit for the main primary panels and all the secondary panels for receptacles circuits and for lighting circuits as well. I installed some MC cable as well and some Rigid conduit too. I had two or three apprentices under my supervision at any given time that included the lining them out on what needed to be done, what materials needed to be used and that it was done by blueprints and by NEC. This job was acquired through craigslist and was just a job that ended when it was completed.

Experience: Roy Jackson Electric Co. 6080 West 59th St.,

Arvada, Colorado 80003. From: Dec.29,2014-May 4th,2015. With Jackson Electric I worked On a apartment complex installing and building Power services for each building. I did the rough-in

and trim on several of these apartments. I also did Hot checks and trouble-shooting on each apt. to Insure that everything worked correctly. I operated the trencher and backhoe to install all the Landscape and outside lighting in PVC conduit.

Experience: American Service Available/via E.C.E Electric Co

6342 Northridge St. Virginia. From:June 2014-Oct.2014 With E.C.E. Electric, I worked installing electrical devices for, “The Movie Tavern” in Aurora. I ran E.M.T. conduit and THNN wire for lighting

and receptacles. I also assisted in the installation of the transformer and disconnect for power. This entire project was a refurbishment of an existing movie theater. The job was through a temporary service with an electrical company that was out of

state as well. Once completed I was laid off.

Experience: Anadarko Petroleum/via Kenny Electric Co.

595 Quivas St. Denver, Co. From:Feb. 2014-May 2014 with Kenny Electric, I worked on a natural gas processing facility with the installation of all the bonding of the entire facility and the installation of disconnects and services for various buildings

in the processing facility. I also assisted with some of the installation of the secondary power and the installation of Rigid conduit and pvc conduit.

Experience: Aerotek Staffing Agency From: Dec 2013-To:Feb. 2014

2000 S.Colorado Blvd. Denver, Co.

With this company I worked with Metron Electric and my duties included the installation of EMT,Rigid and cable for lighting, breaker panels, PLC panels, and MCC panels. Also assisted in the installation and wiring of control panels for oil and gas buildings which involved in the installation and labeling of cables and control wiring for control panels, power panels.

Experience: Titan Electric co. From: July 2013-OCT 2013

4954 Ward rd. Wheat Ridge, Co. Here with Titan Electric, I worked doing commercial electrical applications that involved H&M's clothing outlets, Qdoba restaurants, and new renovations for business'. I managed two to three other apprentices under my supervision and laid out these individuals with what needed to be done per blueprint and NEC code book. I also worked doing Industrial electrical applications that involved the installation of rigid conduit liquid tight flex and EMT conduit. I also assisted in the installation of control boxes, service disconnects and service power panels.

Experience: Premier Group From: May 2013-July 2013

955. Broadway Denver, Co. With this company I worked with two different electrical companies that included commercial construction. I was involved with the gutting and reconstruction of the 26th floor at the Tabor Center, 1201 16th St. #209, Denver,Co. my duties were to read the blueprint and execute the wiring of the project with emt, mc cable, replace lights and replace exit signs and any other electrical device that was called for. With the second company, Axis Elect. I worked reconstructing an existing church. Here I read the blueprint and ran emt, mc cable, fire alarm (low-voltage) and other electrical devices. I also worked doing some Industrial applications which included the installation of rigid conduit, liquid tight flex cable and power panels and disconnects for service.

Experience: RMK Electric Co. From: Nov.2012-April 2013

15467 E. Hinsdale Cir. Fourth Year Apprentice Centennial, Co

With this company I worked on the Pearl St. Apartment complex running emt, mc cable, and rigid. I also did the foundations for each unit and garage parking. I also was involved in the installation and building of the switchgear and mains power panels, disconnects and control panels.

Experience: Alpha Electric Co. From: Feb.1995-Aug. 2012

913 12th St. NW Albuquerque, N.M. With Alpha Electric I was involved in many different aspects of the electrical trade. I worked changing services, did a lot of outdoor lighting such as street lights, landscape lighting, commercial outside lighting. I also did a lot of industrial projects that involved a hydro- conduit factory, government based projects and some services calls. With the hydro-conduit plant I assisted with the installation of EMT,Rigid and liquid tight flex conduit for lighting, receptacles. I also installed various power panels,PLC panels, control panels and MCC equipment. This installation was for motors, generators and automation and various other equipment. We labeled all the wiring and cables for 600+volts. When working with the government projects, I assisted with the installations of conduit and cable for mostly communication based projects. We installed low voltage wiring for fire alarms and tele-communications as well.



Contact this candidate