Post Job Free

Resume

Sign in

Power Plant General Manager

Location:
Biman Bandar, Dhaka, Bangladesh
Salary:
400000
Posted:
January 20, 2023

Contact this candidate

Resume:

RESUME OF SUPROBHAT KUMAR GHOSH

CONTACT ADDRESS

Contact No: 019********

E-mail: adusvn@r.postjobfree.com,adusvn@r.postjobfree.com OBJECTIVES

Seeking a challenging career in a reputed organization offering exposure to latest technologies and work environment and providing good career growth, where I can utilize my education, skills and experience for achievement at work.

PROFESSIONAL PROFILE

An Electrical & Electronic Engineering Graduate with about 15 years of experience in the area of erection, commissioning engineering, Operation & maintenance of CCPP/Gas/ Diesel/HFO based power plant, 230/132KV switch yard, 33/11KV switch yard. Good experience in Preventive maintenance, condition based maintenance, breakdown maintenance & emergency maintenance of Instrumentation Control & electrical systems.

During this period I have gained considerable experience on most makes and models of instrumentation associated with temperature, pressure, flow and level control. Initially working as an Asst Engineer(E & I), then Maintenance Engineer(E & I) /Deputy Manager(E/I) & Sr.Manager-I & C. Over those years I have concentrated on developing a more specialized knowledge base relating to the maintenance /trouble shooting & commissioning of various electrical equipment & PLC and DCS / SCADA systems and more specifically to GT/ST/gas/diesel engine control system. I consider myself to have an excellent all round knowledge of instrumentation and a good understanding of computers and control systems. I am a self motivated person and can work as a team member or alone and un-supervised both. I am Capable to “Planning, Organizing, and Leading & Controlling of New & Existing Power Project independently with Administering, Management, Engineering & Analysis”. I may well to perform as a keen planner & strategist skills in troubleshooting, team building capability & proven abilities in Planning

& Managing resources.

PARSONAL PARTICULARS

Name :Suprobhat Kumar Ghosh.

Father’s Name :Sujay Kumar Ghosh.

Mother’s Name :Bithika Rani

Permanent Address :C/O Sujay Kumar Ghosh,

Vill-Muldair, Post-Dawata Thana -Narail. Dist- Narail. Mail Address :C/O Sukanto Ghosh (Bapi), Lecturer (Mathematics) Shaid Police Smrethe College, Mirpur-14, Dhaka1206. Date of birth : 23- January’1986.

Sex : Male

Marital Status : Single

Religion : Hindu

Blood Group : B+

Nationality : Bangladeshi (By birth)

E-mail :adusvn@r.postjobfree.com

Cell Phone :+88-019********

PROFESSTIONAL EXPERIENCE

1. Company Name : KEPCO Plant Service & Engineering Co. Ltd. & China Northeast Electric Power Engineering & Services Co. Ltd.

Position Held : Sr. Manager(Engineer, I & C).

Project: KEPCO KPS was assigned for O&M of Summit Meghnaghat Power Company Limited,337MW Dual Fuel power plant. It comprises Gas Turbine (2 X GE 9171E) and with HRSG (Hangzhou Boiler Group CO,LTD, Type:NG-S209E-R1) & Steam Turbine (LN124-7.3/503/260, Harbin Turbine Co., Ltd.,). From October-2013 to April,2022, Then handover to China Northeast Electric Power Engineering & Services Co. Ltd with automatically shifted of employment. Service Tenure : 1

st

April,2016 to till now.

Job Responsibilities:

• Supervising, Maintenance & Troubleshooting of GE gas turbine control system Mark-Vie, Mark Vle HMI, along with other accessories of GT control system.

• Supervising, Maintenance & Troubleshooting work of DCS (ABB symphony +), Server, client HMI

& others associate accessories.

• Maintenance and Troubleshooting work of both micro & modular PLC (Ge-fanuc, Siemens-Step7- 400),HMI & other accessories.

• Maintenance and Troubleshooting work of different type of control valve(hydrologic, pneumatic & motor operated).

• Maintenance and Troubleshooting work of different types of field instrument (PIT,TIT, PI,PI,LIT,LI,FIT,FI & others instrument)

• Demonstrate skills in the use of tools, test equipment and calibration appliances. Strong engineering aptitude, basic understanding of chemistry, physics, electricity and mathematics;

• Good understanding of visually read and respond to computer-generated data, instrumentation, gauges, readouts and variations in color;

• Properly Co-operation with foreign expert and all others department.

• Assist in inventory of spare parts and supplies

• working in a multi cultural environment, clear documentation and have very good English skills.

• Adhere to health, safety and environmental guidelines & procedures of the plant and strive to maintain an injury free environment. Having good knowledge on ISO & OSHA standards.

• Maintaining Emergency Recovery system for unexpected emergency situation of the plant

• Training & development of Employees for improvement of Maintenance skill. 2. Company Name : Sinha Power Generation Company Limited.

(50 MW Power Plant, Amnura, Chapai Nawabganj)

Position Held :Deputy Manager (E & I), In-Charge (Electrical & Instrumentation) Service Tenure: 3th March,2015 to 31st March,2016. Job Responsibilities:

• Supervising, Maintenance & Troubleshooting of 50 MW HFO based power plant (Engine Model STX - NIIGATA 16V34 HLX).

• Supervising, Maintenance & Troubleshooting 55/73 MVA ; 11/132 KV step up power transformer.

• Supervising, Maintenance & Troubleshooting different switchgear panels, control panels and HMI, control system and instruments.

• Design and modification of different electrical systems for the power plant.

• Calibration of all Instruments (Level transmitter, pressure switch, Pneumatic water control valve, Steam control valve), HFO and DO Pressure Regulating valve.

• Planning & implementation of all Electrical and Instrumentation & Control related works and supervising a team during the work.

• Troubleshooting and maintenance of all types of instruments like temperature sensors, pressure transmitters, flow meters, rpm sensors, level transmitters, conductivity transmitters, pressure switch, position transmitters etc.

• Troubleshooting and maintenance of PID control system for controlling the parameters of process.

• Fault analysis to find the actual reason of fault and make the required modification to minimize the fault for smooth operation of the plant.

• Troubleshooting, maintenance and repair of any electrical faults in the plant related to engine, auxiliary equipment and utilities with co-operation of the operation team and assist the procurement process for the damaged items.

• Keep eye on the abnormalities of different system including fuel system, lube oil system, water system, HRSG system, engine generator control system and switchgear system and also troubleshooting of any electrical faults in the plant during the operation. 3. Company Name : Vinarco Service (Thailand) Ltd.

Position Held : I/E site supervisor.

Project : Chevron Bangladesh Ltd (BYD) under FE-Construction ( By-WP,NP ) Service Tenure : 19

th

October,2013 to 2

nd

March, 2015.

Job Responsibilities:

• Provide construction & Supervision of all electrical and instrumentation installation & repair site leadership focused on the safe execution of the project scope of work.

• Hands on involvement in site supervision and management of construction supervisors and technicians. which includes installation, inspection, pre-commissioning and commissioning to ensure the projects executed in Health, Safety, Environment, Quality Assurance and Hazard Policies and Precautions, efficient, cost effective and timely manner.

•Responsible for Playing on-site role with different contractors, Such as bellows.

* Check and monitor equipment check list, HA, JSA and PTW documents.

* Identity unsafe act and condition, safe work practices on site.

* Attend and participate in Daily Tool Box Meeting.

* Construction responsibilities include field engineering & management coordination with others departments

• Carry out all tasks about Emergency generators, process lighting system, power distribution system, power surge/lightning protection system.

• Installation, pre-commissioning & commissioning of Diesel Gen-set, Gas Gen-Set, Switch Gear, Synchronising Systems.

• Installation, pre-commissioning, commissioning & calibration of various Instrument(PIT, TIT, LIT, GD, FD, HD), & Make coordination with various instrument to Process Control Systems(DCS-Yokogoa) & fire & gas alarm systems( Honeywell) .

• Properly Co-operation with foreign expert and all others department.

• working in a multi cultural environment, clear documentation and have very good English skills.

• Understanding and able to navigate various computer programs including Microsoft projects. 5. Company Name : Meghna Group of Industries.

Fresh Villa, House # 15, Road # 34, Gulshan-01, Dhaka-1212. Type : Power Generation & manufacturing Company.

Position Held : Maintenance Engineer(E & I).

Project : There are Two project Unique Power Plant & Aversst Power Generation Co. ltd in Meghna ghat, sonargoan, narayangonj, under SPP total capacity about 60MW, supply to different industries of MGI, Local customer & REB with Gas Engine based (5+3 ROLLS-ROYCE engine) plant & a Open Cycle steam turbine.

Service Tenure: 1st November, 2011 to 18th October,2013. Job Responsibilities:

• Operation & maintenance of (27.5+25.17) MW Gas fired power plant.

• Maintenance of gas based engine and their corresponding generator having 3.6 MW capacities of 3 Nos ROLLS-ROYCE engine(KVGS18G4),and 8.40 MW of 5 nos ROLLS-ROYCE engine(B35:40-V20AG), along with 8 load feeder & 2*25MVA Power Transformer with OLTC.

• Perform diagnostic works on electrical faults and Plant outages; recommend modification and improvement on Plant equipment as may be appropriate. Perform maintenance work as and when instructed.

• Monitor and control all running equipment parameters following prudent operating practice.

• Major Maintenance of Engine Power Plant, Plant BOPS, Troubleshooting of Electromechanical Instrument, Load Management, and Development of Operational Philosophy of the Power Plant etc. Engine Overhauling, Supervising and Monitor Pre-commissioning, Testing and commissioning activities of Plant/Facility.

• Take initiative for prudent operations at Fault condition and achieve a good concept about Transformer protection, Outgoing feeder protection (11KV, 33KV), Alternator protection & various types of relay.

• Carry out all tasks about Emergency generators, process lighting system, power distribution system, power surge/lightning protection system.

• Operation & maintenance services including overhauling/repair/fitting activities of standard electrical equipments, associated auxiliaries and related systems of 53MW Gas fired power plants.

• Working Instruments :PLC(Siemens, S7-300), AVR(BASLER DECS 100,Leroy Somer R610,ABB Unitrol 1000), Electronic Governor(Wood Woard 723), PPU(DEIF), Differential Protection Relay(DEIF),Ignition Controller(Altronic CPU-95),Synchronies Device(Wood Ward)

& various types of controller.

• Calibration and maintenance of various types of control actuators e.g. motorized control valves, Knock Sensor, Pressure Transmitter, Flow Transmitter, Temp Transmitter, Electronic Diff: Pressure/ Pressure transmitter, Flame detectors, Solenoid valve, Magnetic Pickup, Pt100, Pt1000, Thermocouple, Pressure switches, Pressure gauges, Proximity.

• Maintenance, repair and troubleshooting LT & HT Circuit Breaker { Energypac VCB (11 KV, Out door type,33KV) ACB, MCCB& MCB}& switch gear component.

• Maintenance, repair and troubleshooting LT & HT switch gear component and Good concept about Power Transformer, Distribution Transformer protection, Low Voltage MCC and Switchgear protection system, vast knowledge on coordination between the protection systems.

• Well conserving in calculating protective relay {Over current & Earth fault relay (IDMT) Model- MiCOM P122, Mikro, MK 2200},Voltage & Frequency(IDMT) Model-MiCOM P127,Transformer Differential Device MiCOM632} ),Trip Circuit Supervision Relays,Master Trip Relays etc} settings.

• Maintenance, repair and troubleshooting AC/DC motor and its starter, (Star-Delta, and dol).

• Oil change & centrifuge of 11/33 KV, 2*25 KVA Power Transformers.

• Good concept Daily power production report, Tariff analysis and Fuel calculation.

• Supervision & Maintenance of more than 15KM over head lines, AC & DC distribution with battery Charging System.

• Assist in requisitioning parts and supplies.

6. Company Name : Doreen Power Generation & Systems Ltd. Mohakhali Tower(11th Floor) 82,Mohakhali C/A,Dhaka-1212. Type : Power Generation Company.

Position Held : Maintenance Engineer(E & I).

Project : There are Two project 22MW & 11MW in feni supply to the BPDB & REB respectively with Gas Engine based (8+4,GE-Jenbcher Engine) plant. Service Tenure : 5th December, 2009 to 31st October, 2011. Job Responsibilities:

• Working as an Maintenance Engineer (E & I) In charge of Instrumentation, Electrical and Electronics maintenance 22MW & 11MW of Feni site.

• Operation and Maintenance of22 M.W. & 11 M.W. based power plant powered by 12 GE Jenbacher gas engine of model JGS 620 –GS NL.

• Perform diagnostic works on electrical faults and Plant outages; recommend modification and improvement on Plant equipment as may be appropriate. Perform maintenance work as and when instructed.

• Perform all schedule and breakdown maintenance such as transferring oil, engine, switchgears etc. all safety precautions.

• Take initiative for prudent operations at Fault condition and achieve a good concept about Transformer protection, Outgoing feeder protection (11KV, 33KV), Alternator protection & various types of relay.

• Carry out all tasks related to maintenance, repair and overhaul of Equipment such as Main Engines

(GE-Jenbacher gas engines, 2.9 MW, 1500 rpm, 12 units), Main Alternators (4400 KVA, 50Hz, 11kV, pf 0.8, 12 units), Step Up Transformer (30000 KVA, 11KV to 33 KV, one units & 15000 KVA one Unit. Step Down Transformers (1500 KVA, 11KV to 0.4 KV one unit & 750KVA one Unit), fire pumps package, Emergency generators, process lighting system, power distribution system, power surge/lightning protection system.

• Working Instruments :PLC(Jenbacher DIA. NEXT with distributed I/O), AVR(BASLER DECS 100), Electronic Governor(PANDOROS, Heinzmnn), Generator Protection Relay(MRG3),Differential Protection Relay(Wood Word, ESDR-4),Ignition Controller(Wood Word, IC920),Synchronies Device(Wood Ward),Sine wave inverter & various types of controller.

• Calibration and maintenance of various types of control actuators e.g. motorized control valves, Knock Sensor, KLS98-interface card, Pressure Transmitter, Flow Transmitter, Temp Transmitter, Electronic Diff: Pressure/ Pressure transmitter, Flame detectors, Solenoid valve, Magnetic Pickup, Pt100, Pt1000, Thermocouple, Pressure switches, Pressure gauges, Proximity.

• Maintenance, repair and troubleshooting LT & HT Circuit Breaker {AREVA, Energypac VCB

(11 KV),ABB VCB(Out door type,33KV) ACB, MCCB& MCB}& switch gear component.

• Maintenance, repair and troubleshooting LT & HT switch gear component and Good concept about Power Transformer, Distribution Transformer protection, Low Voltage MCC and Switchgear protection system, vast knowledge on coordination between the protection systems.

• Well conserving in calculating protective relay {Over current & Earth fault relay (IDMT) Model- MiCOM P122},Voltage & Frequency(IDMT) Model-MiCOM P923,Transformer Differential Device MiCOM632},Distance Protection Relays MiCOM-P441 ),Trip Circuit Supervision Relays

,Master Trip Relays etc} settings.

• Maintenance, repair and troubleshooting AC/DC motor and its starter, (Star-Delta, Auto transformer, Soft starter and DOL).

• Oil change & centrifuge of 11/33 KV, 30000 KVA & 15000KVA Power Transformers.

• Good concept Daily power production report, Tariff analysis and Fuel calculation.

• Properly Co-operation with foreign expert and all others department.

• Implementation safety program, safety planning and installation fire and safety network.

• Monitoring load-dispatching system & maintaining coordination with LDC, PGCB, PDB Distribution & REB Complain centre.

• Able to visually read and respond to computer-generated data, Instrumentation, Gauges, readouts and variations in color.

• Supervision & Maintenance of over head lines, AC & DC distribution with battery Charging System.

• Implementation safety program, safety planning and installation fire and safety network of 22MW

& 11MW plant of Feni site .

• Assist in requisitioning parts and supplies.

• Manage the administrative works of the plant.

7. Company Name: Seven Circle (BD)Ltd.

A unit of Sung Sing Group, Hong Kong.

Land View(7th floor),28 Gulshan North C/A,Gulshan-2, Dhaka-1212. Type : Manufacturing .

Position Held : Asst. Engineer(E&I).

Factory : There are a big Project including a Cement Plant(3000MT per day), a Synthetic Bag Plant and a 10.2MW Power Plant in Charmirpur, Kaligonj, Gazipur Service Tenure :1st April, 2007 to 4th December,2009. Job Responsibilities:

• Erection & Commissioning of 75 T/H Cement Mill, 55 T/H Drum Dryer & 8spout Roto Packer Packing plant.

• Monitoring load-dispatching system & maintaining coordination with other department.

• Maintenance and trouble shooting of PLC (Siemens S7-400, S7-300,Schneider Eclectic, MITSUBISHI & Omron), Inverter (Siemens, Fuji, Danfoss, and ABB), Controller (Temperature, Level, Pressure) & DCS Control system.

• Trouble shooting & Maintenance, Phage Advancer, Weigh feeder, Induction Motor (Squrial case & wound rotor type),Liquid Rheostat.

• Calibration and maintenance of various types of control actuators e.g. Pneumatic and motorized control valves, Pressure Transmitter, Flow Transmitter, Temp. Transmitter, Level Transmitter, Electronic Diff: Pressure/ Pressure transmitter, Solenoid valve Pt100, Pt1000, Thermocouple, Pressure switches, Pressure gauges, Proximity, Load Cell., ST 3000 Smart Transmitter Series 900, Electronic Diff: Pressure/ Pressure transmitter (Model:- STD), Pneumatic valve with positioner

(Valtex, Fisher, and Yamatake), Flame detectors, & Burner Control Unit .

• Maintenance, repair and troubleshooting LT & HT { VCB (11 KV), ACB (3000A, 1000A), MCCB} switch gear component and PFI unit function.

• Maintenance, repair and troubleshooting LT & HT switch gear component and Good concept about Power Transformer,Distribution Transformer& Transformer protection, and Medium Voltage MCC and Switchgear protection system, vast knowledge on coordination between the protection systems.

EDUCATIONAL QUALIFICQTION

Name of

Examination

University/Board University/College/S

chool

Passing Year Class/Division

B.Sc in Electrical &

Electronic

Engineering

Rajshahi University

of Engineering &

Technology

(RUET)

Rajshahi University

of Engineering &

Technology

(RUET)

2006(Held

in February,

2007)

2nd Class

(CGPA: 2.88

out of 4.00 )

Higher Secondary

Certificate

Examination(H.S.C)

Jessore

Abdul Hye College,

Narail

2002 1st division

(71.8% of

marks)

Secondary School

Certificate

Examination(S.S.C)

Jessore

Dattapara High

School, Narail

2000 1st division

(78.3% of

marks)

PROFESSIONAL QUALIFICATIONS

Training Title Trainer Duration

a). Advanced PLC with SCADA system

and its Application in Process

Automation and Control.

b). Simens Step-7 basic.

c)Basic Control Valve Training.

a)Training Institute for Chemical Industries

(TICI) Polash, Narsingdi.

b).Thickage Technology, Kolkata, India at

Meghna Group Of Industries.

c).Emerson Process Management, held at

Dhaka.

a)Two

weeks

b)One

weeks.

c). One

weeks

LANGUAGES

• Bengali (Mother tongue)

• English(Excellent reading, writing and speaking capability). REFERENCES

Reference 1: Nantu Kumar Dey Reference 2: Md. Kamal Uddin General manager(Cement Plant) Assistant General Manager, Seven Circle (Bangladesh)Ltd, Doreen Power Generations & System Ltd.(Feni) A Unit Of Shun Sing Group, Hongkong. Cell: 017********, 019********. Factory: Chairmirpur Kaligonj, Gazipur.

Cell.017********

DECLERATION

I the undersigned certify that to the best of my knowledge and believe, the information specified in the resume correctly described my qualification and me.

Applicant’s Signature



Contact this candidate