Post Job Free

Resume

Sign in

Aircraft Painter Agent

Location:
Austin, TX
Posted:
January 10, 2023

Contact this candidate

Resume:

General Industrial Coatings

CC-M**

MIL-DTL-*****C, Type II

Waterborne Polyurethane

Chemical Agent Resistant Coating

Aircraft Green, 34031 F93G505 Green 383, 34094 F93G504 Foliage Green, 34160 F93G509 Brown 383, 30051 F93N505 Tan 686A, 33446 F93H504 Black, 37030 F93B505 Aircraft Black, 37038 F93B506 Interior Gray, 36231 F93A501 Catalyst (Component B) V93V502 Woodland Desert Sage, 34201 ... F93G510 Olive Drab, 34088 F93G512 CC-M21 6/22 continued on back

DESCRIPTION

MIL-DTL-64159C, Type II coatings are two

component waterborne polyurethane

chemical agent resistant coatings (CARC)

for military equipment. They meet the

performance and composition of the MIL-

DTL-64159C, Type II specification. They

can be effectively decontaminated after

exposure to liquid chemical agents.

Advantages:

• VOC* of less than 1.8 lbs./gal

• Less than 0.9 lbs./gal Volatile Organic

Emissions

• Reduces with water

• Low odor

• Excellent atomization

• Smooth finish versus standard CARC

• May be applied with two component

equipment

• Free of lead and chromate hazards

• Excellent exterior durability

The following MIL-DTL-64159C, Type II

products are approved by the U.S. Army

Research Lab, Aberdeen Proving Grounds,

Aberdeen, MD:

Sherwin-Williams QPD

F93G504 Q1653

F93H504 Q1660

F93B505 Q1655

F93N505 Q1654

F93G505 Q1661

F93B506 Q1680

F93A501 Q1765

F93G510 Q1910

F93G509 Q1764

F93G512 Q2168

* VOC Compliance limits vary from state to

state; please consult local Air Quality rules

and regulations.

An Environmental Data Sheet is available

from your local Sherwin-Williams facility or

at www.PaintDocs.Com.

CHARACTERISTICS

60 Gloss: 3.0 units max

85 Gloss: 8.0 units max

Refer to MIL-DTL-64159 for specific gloss

requirements by color.

Recommended Film Thickness:

Mils Wet 3.9-8.1

Mils Dry 2.0-3.0

Drying: (2.0 mils DFT, 70 F, 50% RH)

To Touch 60 minutes

To Dry Hard 6 hours

Through-Dry 8 hours

Total (Full Properties) 7 days

Force Dry: Flash 60 mins. then dry 45

mins. @ 140 F

Flash time is dependent on air movement,

humidity, and temperature. The one hour

flash can be reduced with an air dehydrator

or fans to help remove the water. All the

water must be out of the coating before force

dry.

Flash Point 200 F

Mixing Ratio (by volume):

Component A 2 Parts

Component B (V93V502) 1 Part

Reduce as needed up to one part per

volume of water, or as recommended by

manufacturer.

Pot Life: 6 hours

Package Life: 18 months, unopened

Inside storage

Air Quality Data:

• Non-photochemically reactive

• Volatile Organic Compounds (VOC)

o catalyzed and reduced as above,

maximum 1.8 lbs./gal, 216 g/L

• Volatile Organic Emissions

o catalyzed and reduced as above,

maximum 0.9 lbs./gal, 108 g/L

SPECIFICATIONS

CLEANING & PRETREATMENTS

Follow the most current revisions of MIL

DTL 53072 and/or TT C 490 for required

cleaning and pretreatment application

before applying primers and/or topcoats.

For ferrous substrates, use: MIL-DTL-

53022 Types II, III, IV or V; MIL-DTL-53030

Type II; MIL-PRF-32348 Type I or Type II; or

MIL-DTL-53084 electrocoat.

For non-ferrous substrates, use: MIL-DTL-

53022 Types II, III, IV or V; MIL-DTL-53030

Type II; MIL-PRF-32348 Type I or Type II;

MIL-DTL-53084 electrocoat.

Note: See the current MIL-DTL-53072 for

complete details regarding substrate

preparation, coatings, and application.

Testing: The information, data, and

recommendations set forth in this Product

Data Sheet are based upon test results

believed to be reliable. However, due to the

wide variety of substrates, substrate

properties, surface preparation methods,

equipment and tools, application methods,

and environments, the customer should test

the complete system for adhesion,

compatibility, and performance prior to full

scale application.

CC-M21 MIL-DTL-64159C, Type II, Waterborne Polyurethane, Chemical Agent Resistant Coating APPLICATION

Typical Setups

Reduction: Reduce with deionized or

distilled water.

Cleanup/Reduction: Clean

tools/equipment immediately after use with

water.

For application and usage guidelines,

please contact your local Sherwin-Williams

sales rep.

Note: See MIL-DTL-53072 for complete

details regarding substrate preparation,

coatings and application.

ADDITIONAL INFORMATION

1. These coatings (Component A) must be

catalyzed with Catalyst (Component B),

V93V502, at 2:1 ratio by volume.

2. Do not use other catalysts other than

V93V502. Do not vary catalyst mixing

ratio.

3. Component A must be well agitated prior

to use by using a paint shaker.

4. Component A, Component B, and

Reducer must be mixed well with a

mechanical mixer.

Performance Properties: Meets all the

performance properties of MIL-DTL-

64159C, Type II.

CAUTION:

Admixed material should not be

discarded in sealed drums. Vented plugs

should be used on the drums. This

material will generate carbon dioxide gas

within the first 24 hours of being mixed.

After the material has been mixed for 24

hours, the gas is no longer emitted, and

the drums can be sealed.

All trademarks are the property of their

respective owners.

CAUTIONS

FOR INDUSTRIAL SHOP APPLICATION

ONLY

Thoroughly review product label and

Safety Data Sheet (SDS) for safety

information and cautions prior to using

this product.

To obtain the most current version of the

Environmental Data Sheet (EDS), Product

Data Sheet (PDS), or Safety Data Sheet

(SDS), please visit your local Sherwin-

Williams facility or www.PaintDocs.Com.

Please direct any questions or comments to

your local Sherwin-Williams facility.

Note: All purchases of products from

Sherwin- Williams are exclusively subject to

Sherwin-Williams' Standard Terms And

Conditions Of Sale. Please review these

terms and conditions prior to the purchase of

the products.

Sherwin-Williams warrants the product to be

free of manufacturing defect in accordance

with Sherwin-Williams’ quality control

procedures. Except for the preceding

sentence, due to factors that are outside of

Sherwin-Williams’ control, including

substrate selection, and customer handling,

preparation, and application, Sherwin-

Williams cannot make any other warranties

related to the product or the performance of

the product. SHERWIN-WILLIAMS

DISCLAIMS ALL WARRANTIES OF ANY

KIND, EXPRESS OR IMPLIED,

INCLUDING BUT NOT LIMITED TO THE

IMPLIED WARRANTY OF

MERCHANTABILITY, THE IMPLIED

WARRANTY OF FITNESS FOR A

PARTICULAR PURPOSE.

Liability for products proven to be defectively

manufactured will be limited solely to

replacement of the defective product or the

refund of the purchase price paid for the

defective product, as determined by

Sherwin-Williams. Under no circumstances

shall Sherwin-Williams be liable for indirect,

special, incidental or consequential

damages, lost profits or punitive damages

arising from any cause whatsoever.



Contact this candidate