CURRICULUM VITAE

e-mail : adt0xo@r.postjobfree.com

Personel mob : +91-944*******

PERSONAL DETAILS:-

SARAVANAKUMAR . A

Date of Birth : 07-06-1983

Nationality : Indian

Sex : Male

Marital Status : Married

Blood Group : B +ve

Languages Known:

English, Tamil and Hindi.

Passport Details:

Passport No. : P7346371.

Valid up to : 15.02.2027.

Issued at : Chennai.

Permanent Address:

No : 160 / 1, T.K.M.Road,

Vallam Post, Chengalpattu.

Tamil Nadu, India.

Present Company:

M/s.Dhawin Engineering.

Chennai. (Mar 2021 to Tilldate)

Previous Company:

1. M/s.Galaxy Energy General

Contracting Companey LLC –

UAE – Abudabi.

(Dec 2018 to July 2020)

2. M/s.Dhawin Engineering.

Chennai. (Jan 2017 to Dec 2018)

3. M/s. Larson And Toubro LTD

Mumbai. (Jan 2012 to Oct 2016)

4. M/s.Sterling and Wilson Ltd.

Kerala. - (Nov 2009 to Jan 2012)

5. M/s.SSEngineering Chennai.

(March 2008 to Oct 2009)

6. M/s.Voltech Engineers Pvt Ltd.

(March 2006 to Jan 2008)

Objective:

Professional carrier in your concern which offers

continuous development opportunity and to draw

satisfaction from personnel and organization growth. Professional Details:

Professional Qualification:

Bachelor of Electrical and Electronics Engineering. Institute : Arulmigu Meenakshi Amman College of

engineering.

University : Madras University

Year of completion : 2004.

HIGHLIGHTS:

Carrying the job to the customer’s standard with safety and initiative’s creativity, communication & achieving the work at stipulate time.

Experience:

Having around 15 Years of experience and knowledge in the field of

a) Testing & Commissioning of Substation Equipments, Protective Relays, Power Transformers and Power plant Equipments.

b) Substation Maintenance Work.

c) Auto cad Drawing.

Graduate Traine:

Tamil Nadu Eletricity Board (TNEB) – 230KV,110KV

Substation Grid Relay Testing (GRT).

Graduate Apprentice Trainee. (March 2005 to Feb 2006) Page 2 of 5

RESPONSIBILITIES IN EXECUTION OF PROJECTS :-

Testing & Commissioning of Electrical Equipments (Switchyard - PowerTransformers, Generators, CT, CB, Disconnectors, Earth switches and Protective Relays).

Scheme checks and Relay co-ordination as per specification.

Preparation of safety documents and method of statements for outages.

Preparation of As built drawings, cable schedule and Site acceptance test records according to the specifications.

Co – ordination with Relay Engineer and SCADA & DCS Engineer.

Trouble shooting of all Electrical control Panels and protection circuits.

Regular Surveillance / Inspection of construction activities as per Project Specification and test plan. Reporting to QA/QC Manager, on any major issues, which require immediate action.

Instrumentation material receiving Inspection & Issuing material discrepancy reports for any deficiency.

NATURE OF WORK :-

Testing and commissioning of all Electrical equipment from 415Volts Systems and 230KV & 400KV Substation.

Testing and commissioning of LV, MV, HV Switchgears, Switchyard (CT, CVT, CB, Busbar, Disconnector, Earth switch, Transformers).

Panel Erection and Cable Laying Co-ordination with Project Team.

Transformer and Motor Protection relays (Differential, Over current & Earth fault, REF and Stability and schemes.

Inspection of control and relay panel, preparation of Test Report and Operation & Maintenance for sub-station, power plant.

PRESENT PROJECTS :-

Project 1

Company : Galaxy Energy General Contracting LLC.

Client : ROBOT STONE.

Customer : ADNOC.

Designation : Electrical Commissioning Engineer.

Location : Hubsan PMRF Project

Duration : Feb 2020 to Till date.

Pre-Inspection with site engineer / Verification of activities before raising RFI.

Raising & closing of punch list for various types of E&I work. Page 3 of 5

Project 2

Company : Galaxy Energy General Contracting LLC.

Client : LTHE

Customer : Al DHAFRA Petrochemical Operation Company LTD.

Designation : Electrical Commissioning Engineer

Location : Haliba Development Project

Duration : Dec 2018 to Jan 2020

Pre-Inspection with site engineer / Verification of activities before raising RFI.

Raising & closing of punch list for various types of E&I work. Magagenco Thermal Power Project 3x660MW Tpp – Koradi.

400KV Switch yard Equipment testing and commissioning.

Testing & commissioning of 11KV / 3.3KV / 0.433KV Switch gear Panels (500 Panel – C&S), Transformers (2.5MVA), Areva Relays, Protection Schematic and Operations,

Preparation of contract completion documents for technical support.

Preparation of Method of statement and safety document to the outages and As built drawings and cable schedules for approvel.

330MVA G.T – Testing and Commissioning work.

63MVA ST – Testing and Commissioning work.

20MVA UAT – Testing and commissioning work.

BUS Transfer System (BTS) Testing and Commissioning. Indiabulls Thermal Power Project 5x270MW Tpp – Nashik.

Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (300 Panel – L&T), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

Preparation of contract completion documents for technical support.

Preparation of Method of statement and safety document to the outages and As built drawings and cable schedules for approvel.

330MVA G.T – Testing and Commissioning work.

63MVA ST – Testing and Commissioning work.

20MVA UAT – Testing and commissioning work.

Rattan india Thermal Power Project 5x270MW Tpp – Amravati.

Testing & commissioning of 6.6KV / 0.433KV Switch gear Panels (100 Panel – L&T), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

Preparation of contract completion documents for technical support.

Preparation of Method of statement and safety document to the outages and As built drawings and cable schedules for approvel.

330MVA G.T – Testing and Commissioning work.

63MVA ST – Testing and Commissioning work.

20MVA UAT – Testing and commissioning work.

BUS Transfer System (BTS) Testing and Commissioning. Page 4 of 5

RAMANUJAR IT PARK.

Client : Alliance 1st. Projects : for EIL.

110KV Switch yard Equipment testing and commissioning.

Testing & commissioning of 11KV / 0.433KV Switch gear Panels (4 Panel – Siemens), Transformers (2.5MVA), L&T Relays, Protection Schematic and Operations,

Preparation of contract completion documents for technical support.

Preparation of Method of statement and safety document to the outages.

Preparation of As built drawings and cable schedules for approvel. CHEYYAR SEZ DEVELOPERS.

Client : CSD. Projects : for EIL.

Testing & commissioning of 11KV / 0.433KV Switch gear Panels (3 Panel – Siemens), Transformers (2.5MVA), AREVA Relays, Protection Schematic and Operations,

Preparation of contract completion documents for technical support.

Preparation of Method of statement and safety document to the outages.

Preparation of As built drawings and cable schedules for approvel. ISRO - THIRUVANDRAM.

Client : ISRO - SPCL. Projects : for EIL.

Testing & commissioning of 11KV / 0.433KV Switch gear, Transformers (2.5MVA), AREVA, E.R Relays, Protection Schematic and Operations of Panels Phase -1,

Preparation of Method of statement and safety document to the outages.

Preparation of As built drawings and cable schedules for approvel. INTERNATIONAL ASSIGNMENT

OIL AND GAS :-

1. QATAR GAS.

Client : QATAR Electricity Board. Projects : QATAR GAS - Raslaffan. Testing and commissioning of 0.433KV Breaker (OC/ EF) Protection ABB Relay. – QATAR. DOMESTIC ASSIGNMENT

OIL AND GAS :-

Testing and commissioning of all Electrical equipment from 415Volts Systems and 11 / 33 KV & 230KV & 400KV Substation.

Page 5 of 5

POWER PLANT, SWITCHYARD, PROCESS PLANTS & SUB STATIONS :-

Testing and commissioning of 33KV AND 11KV SWITCH YARD, 50MVATransformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel Schemes,Relays (SIEMENS). COCHIN SHIP YARD thro Siemens.

Testing and commissioning of 11KV SWITCH YARD, 50MVA Transformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & protection Schemes, Relays(ABB, Siemens).Motorla thro GET.

Testing and commissioning of 132/11 KV/0.433KV SWITCH YARD, 50MVA Transformers, OLTC operation, Auxiliary protections, Differential & REF Stability, Control & Relay panel Schemes,(ER Relays). PGCL – YANAM (A.P).

Testing and commissioning of 0.433KV and 11kv Switchgear, Stability for Transformer 2.5MVA, Auxiliary protections, Control & protection Schemes, Relays(ABB). RAYALSEMA Thermal power plant – RAYALSEMA – A.P thro ABB.

Testing and commissioning of 400KV/ 6.6KV G.T & S.T Transformer Commissioning and 6.6KV & 415V Switchgear, Stability for Transformer 2.5MVA, Auxiliary protections, Control

& protection Schemes, Relays(ABB). Indiabulls Thermal power plant – Amravati & Nasik. Experience with AREVA RELAYS

MiCOM P632 - Transformer Protection

MiCOM P120,P121,P111,P122 - O/C & E/F Protection

MiCOM P220 - Motor protection

Experience with SIEMENS Relays

7SJ6005, 7SJ6225 - O/C & E/F Protection.

7UT612 - Transofrmer Diff.Protection.

7SJ62,63,64 - Multi function Relay

SEL Relay - O/C & E/F Protection.