Professional Objective
Dedicated and highly skilled Instrumentation and Control Manager with meticulous and accurate attention to minute details. Able to work effectively independently or as a team member. Adept at project completion at or well below client budget limits.
Summary
About 12th years of experience as an Instrumentation & control Manager in Erection, Installation, Pre-commissioning, Commissioning, Maintenance, & development of instruments and control system in Power plant, Steel Plant, Furnace, Cement Plant, Refinery & water Treatment plant.
Knowledge of Configuring and faults diagnosis of DCS, PLC, SCADA, Control Philosophy, Control Structure and Control Loops.
Installation, Calibration, & Loop checking of the field instrument, (ABB, Honeywell, Yokogawa, Siemens, Rosemount, Endress & Houser, Bently Nevada, Polysonics, Vega, Forbes marshall).
Maintenance & Calibration of the Control Valves (Pneumatics, Part Turn, NRV, MOV) of weir blackborough, Flowserv, Bray, Valtek, Auma.
Designing, Implementing, and commissioning of new control loops as per site requirement.
Experienced in flowmeters configuring (Electromagnetic, Orifice Plate, Ultrasonic, Turbine, and variable area).
Review of control philosophy, P&I diagram, cause & effect diagram, Instrument List, & flow Chart.
Technical support for the instrument team.
Experienced in the field instruments & control system procurement activities.
Spare balance investigation & inventory control for all instrument parts
PRESENT WORK EXPERIENCE
GHANKUN STEEL & POWER LTD (NIRMAAN GROUP) RAIPUR (CG):- Feb-2017 to Till date
Ghunkun Steel - Manufacturer of power plants, industrial power plant parts & thermal power plants maintenance services in Raipur, Chhattisgarh
Designation: - C&I Manager
Presently associated with the (2x12 mw captive power plant) GHANKUN STEEL PVT LTD RAIPUR (CG)
TECHNICAL EXPERTISE
Leading of Instrument Teams.
Reporting periodically General manager preparing KPI, PM and CM reports.
Troubleshooting the totally integrated automation,
Planning required upgradation for instrument to achieve production quality and cost minimizing.
Co-ordinally daily maintenance activities like, preventive, productive and breakdown.
Planning & executing Shutdown jobs.
Spare Planning & purchases.
Coordinating with contractors for migration works and new schemes.
Troubleshooting of PLC system (Siemens semantic) and faults diagnosis.
Calibration of weighing system including load cell 20ton capacity.
Involved in instrument installation, calibration, cable laying, Termination Calibration and loop checking.
Planning & implementing additional control loops as per site requirements.
Strong background in motor defects, soft-starters, drives, Star/Delta starter, VFD.
CONTROL SYSTEM DETAILS
DCS: -Working in ABB 800XA fully conversant with design, programming & commissioning of ABB DCS 800xAApplication development.
Executed brown filed projects (Engineering and Commissioning) or worked in DCS 800xA system migration projects.
PREVIOUS EXPERIENCE
1. Chhindwara infrastructure (P) ltd Pandhurna (MP) (CLC Spentex Group) July 2014 to November 2016
(2x10 mw Captive power plant)
Designation: - C&I Asst. Manager
Presently associated with the (2x10 mw captive power plant) Chhindwara infrastructure (P) ltd Pandhurna (MP) as Asst Manager.
Job Responsibilities:
Successfully oversaw the installation, commissioning & operation of Siemens DCS and erection commissioning, operation & maintenance of field Side all Instruments.
Gained in-depth knowledge of control drawings & single line diagrams.
Ushered the maintenance of Ash handling system controlled by PLC along with the operation based
on pneumatic system.
Successfully Calibration & maintenance of oxygen analyzer, acid and alkaline analyzer in CPU.
Commissioning of the entire PA, FD & ID fan with lube oil system.
Turbine HP and LP bypass oil skid commissioning work
Calibration, Erection and Loop checking of Pressure and Differential Pressure Switches (PS & DPS) and Level switch (LS).
Calibration, Erection and Loop checking of Temperature Elements (RTD & T/C), Temperature Transmitters.
Calibration and Erection of local indicators such as Pressure and Temperature Gauges (TG & PG).
Supervision in erection of cable Tray, Transmitter rack, Impulse piping and leak proof testing like hydro and pneumatic tests.
2. M/S ANI Instruments PVT.LTD Nov 2013 to June 2014
Designation: - Control &Instrumentation Engineer
Client name: RELIANCE POWER, UMPP, SASAN POWER LTD MP.
Capacity of the plant: 6x660 MW coal based Ultra mega power plant.
Job Responsibilities:
Successfully oversaw the installation, commissioning & operation of DCS and erection commissioning, operation & maintenance of field Side all Instruments.
Ensured regular & effective maintenance, calibration and repairing of various types of Flow, Pressure and Temperature instruments like gauges & transmitters.
Handled the maintenance of the thermocouples and RTDs and pneumatic and electro pneumatic
Actuators, Solenoid operated Heavy Valves and dampers in the plant.
3. Indra Powdergen Pvt. Ltd., Berhampur (CG):
Capacity of the Plant: 1x10 MW Coal based Power Plant
Duration : MAY’ 13 – October 2013
Designation : Sr. Engineer – Instrumentation
4.Arya Energy Limited (2x12 MW), M.P.
Capacity of the Plant: 1x12 MW Coal based Power Plant.
Duration : Oct’ 12 –April 13
Degination : Sr. Engineer – Instrumentation
5. Indra Powergen Pvt. Ltd., Bishrampur (CG):
Capacity of the Plant: 1x10 MW Coal based Power Plant.
Duration : 1st April 2011 to 30th sep2012.
Degination : Engineer – Instrumentation
6. Walchandnagar Industries Ltd., Pune (MH):
Duration : Aug’08 – Mar’11 as Control & Instrumentation Asst. Engineer
Nature of work: -
Developed the instrument specification sheet for various field instruments by using various IN-tools & Auto –CAD Software.
Handled the maintenance of the Instrument Index, I/O list & preparation of bill of material.
Played a key role in the selection & sizing of instruments along with the creation of drawing hook up
Diagrams.
Monitored the preparation of Loop Drawings & drafting of the Control philosophy manual.
Completed effectively the drawing cable tray layout and cable routing drawing.
Oversaw the designing control room layout.
EDUCATION
Bachelor of Engineering (B.E) in Instrumentation & Control, with 68% from Shri Rawatpura Sarkar Institute of Technology and Science, Datia, (M.P.), affiliated to RGPV Bhopal (M.P.) 2007
PROFESSIONAL ENHANCEMENTS
NABL certificate Calibration training in Tempsens Pvt. (I) Ltd., Udaipur (Rajasthan) in 2009.
30Days training on PLC, SACADA & process instrumentation from Softcon, Bhopal in 2009.
IT SKILLS
Well versed with VB .NET, Auto Cad, NX-4 & 5, Pro-E, Solid works, P-Spice.
Conversant in Microsoft Office (PowerPoint, Excel & Word)
PERSONAL DETAILS
Name:
ATUL KHARE
Date of birth:
01/01/1983
Languages:
English, Hindi.
Nationality:
Indian
Sex:
Male
Marital status
Married
Pass port No.
KG107017
Correspondence Address:
GHANKUN STEEL & POWER LTD SILTARA PHASE –II RAIPUR (CG)
Permanent Address
Shri. J.P. Khare
185, Near Nayak flour mills Narsingh Garh colony Chhatarpur (MP)
Pin. 471001
Declaration:
I do hereby declare that the above statements are true to the best of my knowledge and belief.
DATE: ATUL KHARE
Name : ATUL KHARE
Experienced in : EPC Projects, Installation, Erection Commissioning, Operations &
Maintenance & Running power plant.
Industry : Thermal & biomass Power / Energy / Chemical Power
E-Mail : ****.*****@*****.***
Phone : +91-982*******
Address : GHANKUN STEEL PVT LTD RAIPUR (CG)