SHANKAR PRADEEP P
Tamilnadu, India Phone: +91-784******* Email: ******************@*****.***
Carrier Objective
Seeking an outstanding and intellectual career as a Condition monitoring Engineer where I will be a valuable team member contributing ideas and work for an organization where there is ample scope of individuals as well as organizational growth in design and development. To keep myself current according to the changing trends and perspectives. Work History
Aug 2017 - Still - NTPL, Tuticorin Tamilnadu
through NAGARJUNA ENGINNERING CONSTRUCTION Coal
Handling:
Applied technical troubleshooting to create quality conveyer system. Developed internal processes and plans for mechanical verification, product development and factory processes.
Troubleshot and diagnosed equipment issues, quickly made plans for repairs and monitored use to rectify issues.
Applied mechanical problem-solving skills to develop creative solutions for quality products.
Maintaining good teamwork effect and solving the problem easily. Technical Activity:
Daily Inspection on Conveyer Section.
Plan and do the conveyer Maintenance activity.
Submitting the routine damage and failure report through hardcopy and softcopy to concern department.
Manpower allocation to respective department and solving the problems in mechanical field.
Condition Monitoring:
Handled calls to address customer inquiries and concerns. Actively listened to customers, handled concerns quickly and escalated major issues to Concern person.
Managed team of employees, overseeing hiring, training, and professional growth of employees.
Used coordination and planning skills to achieve results according to schedule. Learned new skills and applied to daily tasks to improve efficiency. Project undertaken:
Vibration analysis or all rotating equipment.
Analysing leakage current on Surge Arrestor using leakage current Monitor(LCM) Analysing Hotspot Temperature using IR Thermal imager Using photography analysing the oil's quality and performance Technical Activities:
Analysing the machine data obtained from the software and generating suitable solution by conducting vibration and phase analysis.
Carrying out static and Dynamic Balancing of fans and blowers in single and dual plane as per the requirement.
Monitoring machines vibration and analysing the machine Condition using Spectrum and Phase analysis.
Analysing the problem of bearing condition with the help of software & SKF, SKF HD technique.
Root cause failure analysis for the critical machines Submitting on-site reports on day to day scheduled reports of different departments as well as super critical equipment's health condition weekly twice. Submitting critical and marginal equipment’s reports on the same day for the reference of the departments.
Maintaining the history and trends of all normal and super critical equipment's. • Job distribution to the engineer's and manpower planning and handling. Analysing the machine data obtained from the software and generating suitable solution by conducting vibration and phase analysis.
Instruments and Software's Handled:
Vibration Analysis: SKF MICROLOG ANALYSER AX along with SK' F aptitudes analyst-Version9.O
Hotspot Temperature Monitoring: FLIR E-8
Leakage Current on surge Arrestor using LEAKAGE CURRENT MONIIOR (LC M ) : SCOPE SA 30i+ along with scope software.
Energy Efficiency Monitoring:
Carried out day-to-day duties accurately and efficiently. Worked within applicable standards, policies, and guidelines to pron10te safe working environment
Used Microsoft Word and other software tools to create documents and other communications.
Resolved problems, improving operations, and provide exceptional ideas. Inventory Management,
Technical Activity:
LRSB- (Long Retractable Suit Blowers) Wall blowers - valve temperature Inspection. HEDP- (High Energy Drain Pressure) inspection of vans passing NDCT- (Natural Draft Cooling 'lower) inspection of efficiency in cooling towers. To find the coal pipes choke by using thermal Imaging camera or IRT Thermometer. Power Analysis SEC-(Specific Energy Consumption) for measuring the current voltage, power factor and energy in equipment panels
Instruments and Software Handled:
NDCT (Natural Draft Cooling Tower): PSYSCHRO METER & ANEMOMETER Thermometer
Thermal Imaging camera: FLIR along with FLIR software. Handled Transformers: Inter connection Transformers (2 no's) of capacity 315 MVA, Station Transformers (2 no's) of capacity 63 MVA,
Unit Transformers (4 no's) of capacity 45 MVA,
Unit Auxiliary Transformers (4 no's) of capacity 16 M VA Technical Activity:
Hotspot Temperature to be checked on Oil type and dry type Transformers in a routine monitoring.
Operation and Maintenance of Generating Transformer (R,Y&B PHASE) of capacity 200 MVA
Additionally Covered Areas:
Routine Hotspot Temperature were measured regularly at Switchyard, Panels, Transformers & Motor Terminals.
Operation and Maintenance of 400 KV and 220 KV GIS Sub Station. Operation and Maintenance of SF6 Breakers
Oil Level inspection
Daily inspection done under the control of switchyard measurement level 400 KV and 220 KV GIS
Education
B. Tech in Mechanical Engineering
Kalasalingam University, Srivilliputur
Technical Skill
Vibration Signature Analysis.
Static & Dynamic Balancing Thermography
Oil Analysis
Hotspot Temperature Monitoring
Leakage Current Using Leakage Current Monitor(LCM) Competency:
Problem -Solving
Collaboration
Diligence
Strategy
Communication
Decision-making
Teamwork