Post Job Free

Resume

Sign in

Aramco Qa

Location:
Hyderabad, Telangana, India
Salary:
1
Posted:
September 15, 2022

Contact this candidate

Resume:

*of*

CURRICULUMVITAE

CandidateInformation Name:MUDAVATHPANDIYA Dateofbirth:02-Feb-1984

PassportNo:P8046471 Date of expiry:26-FEB-

2027

Languagesknown:

Tospeak:Telugu,English,Hindi

Toread&write:Telugu,English,

Hindi

Sex:Male

Contactno. 91-

970*******

Nationality:Indian Drivinglicense&country:

Yes&India

TotalyearofExperience:12yrs QA/QCexperience:12yrs

Memberships:ACIMember

Professional

qualificationsincluding

yearofpassing

Qualification Yearofpassing

BachelorofElectronic&

InstrumentationEngineering

2006

DiplomainElectronic&

InstrumentationEngineering

2003

Present

Employer

Designation QCSPERVISORE&I

Nameof

employer

NASSSERS.ALHAJRICORPORATION

Addressof

employer

P.O.Box77378,Al-Khobar31952,5thfloor

NasserAl-HajriTower(Al-saeedTower-2)

Khobar-DammamHighway,KSA

TRAININGSATTENDED:

SL

NO

DATE&DURATION SUBJECTOFTRAINING CONDUCTEDBY

1

21-Oct-2008& 2

days

QualityAwarenessTraining

MohammadAl-Mojil

Group(MMG)

2 06-Aug-2011 QMS&QA/QCFunctionsatSite L&T

3

01-Aug-2012& 2

days

TransformerSiteTraining

PrograminRasLaffan

HYUNDAIHeavy

IndustriesCo.Ltd

COMPUTERSKILLA;

OperationSysytem:WindowsXP,Windows7,WS-10,VISTHA,SCADA,PMS MicrosoftAplication:Microsoftoffice2003,2007&2010,MSWORD… 8of8

EXPERIENCEINABROAD:(PresenttoPast):

SL

NO

PERIOD

OFWORK

DESIGNATION&

Company

Client&

Consultants

NAMEOFPROJECT

1 2017to

2018

NASSERS.AL

HAJRI

CORPORATION

(QC

SUPERVISOR

E&I)

SAUDIARAMCO&

PETROFACSAUDI

ARABIA,FADHILI

FADHILIGASPLANT (SRU

PACKAGE-3)

(SaudiAramcoapproved)

2 2013to

2015

L&TECC&

Assistance

MangaerE&I

(QA/QC)

QatarPetroleum

DUKHAN

EPICFORPOWERFACTOR

CORRECTIONEQUIPMENTFOR

DUKHAN33KVELECTRICAL

NETWORK

3 2011to

2013

L&TECC&

Senior.Engineer

E&I(QA/QC)

QatarPetroleum

RASLAFFAN

IndustrialCity

EPICforElectricalandTelecom

UtilitiesforSupportServiceArea,

PhaseI&IIandWestEnd

Extension.(132/33KVRLF-4

Substation,SS1,SS2&SS3

4 2010to

2011

QA/QCEngineer

E&I&Mohammad

Al-MojilGroup

Co.W.L.L

SABIC(Kayan)&

FLOUR

Kayan-22Project

5 2009to

2010

QA/QCEngineer

E&I&Mohammad

Al-MojilGroup

Co.W.L.L

SABICSharq)&

(FosterWeler.

Sharq3rdExpansionU&O

Project

6 2008to

2009

QA/QCInspector

E&I&(CCIC)

Consolated

Contractor

International

CompanyW.L.L

QatarSHEL&JGC

&KBRJointventure

PEARL-GTL–Doha,Qatar

7 2006to

2008

QA/QCInspector

E&I&(CCIC)

Consolated

Contractor

CompanyW.L.L

ARAMCO&JGC ARAMCOProjectRabigh

OlefinPlantsProject(ROPP)-

Rabigh,K.S.A

8 2003to

2006

LeadEngineer

E&I&

VisakhaSteelPlant 1.Rashtriya–ISpatNigam

Ltd(VisakhapatnamSteel

Plant)India2.Gangotri

TurboTechEggServices–

Hyderabad,

8of8

EXPERIENCE:

Overal12yearofexperienceinthefieldofE&IInspection,instalation Testingandpre-Commissioning,CommissioningworkofvariousElectricaland Instrumentationprojects.AbletounderstandtheprojectdrawingsLogiccircuit diagrams,PMS(PowerManagementSystem)SCADA(SupervisoryControlandData Aquasition)Singlelinediagram,schematicdiagram,generalarrangementdiagram, PingandInstrumentdiagram(P&ID),Interlockcircuitdiagramupstreamanddown stream logicinterlockdiagramsandMCCloopcheckingdiagram,SF6GISPanels, ProtectioncontrolAVRPanels,FACPPanels,FM200Fireprotectioncontrolforswitc gearroom andTelecom room andinstrumentcontrolroometc/Familiarization& Understandingofindustrycodepractices-NEC/NFPA-70,NEMA,API.IEEE.IEC.ANSI, ISA Manuals.FamliarwithEngineeringstandards,ProceducersforElectrical& InstrumentationSystem.

STADARDSANDCODESFAMILIARITY:

SaudiARAMCO EngineeringStandards(SAES,SAEP,SATIP,SATR,SAIC, SAMSS)

NFPA70(NationalFireprotectionassociation)

NEC(NationalElectricaslcodes)

NEMA(NationalElectricalManufacturersAssociation)

IEEE(InistituteofElectrical&ElectronicsEngineers)

NACE(NationalAssociationofcorrosionEngineering)

ICEA(InsulatedcableEngineersAssociation)

ASME(AmericanSocietyofMechanicalEngineers)

ASTM(Americansocietyfortesting&Materials)

ANSI(AmericanNationalstandadInistitute)

IEC(InternaltionalelectroTechnicalCommission)

NETA(Inter-NationalElectricalTestingAssociation) KEYROLES:

ImplementationISO-9000-2008StandardsintheQualityDepartment.

InternalandExternalAuditSchedulingandPlaning/

ConductingInternalassessmentstothequalityteam.

PQPOrentationgiventotheprojectconstructionteam.

Qualityawirnaceprogramsforexecutiveteam/

Projectcoordinatorbetweenclientandcompany.

Coordinatedforcommissioning,operationandprojecthandedoverwithal sparepartsaspercontractrequirements.

QA/QCJOBRESPONSIBILITY:

ProvidedatabaseforElectrical&InstrumentationSystem andforecost requiredITP/QCPform/

Implementationof11kvpowerdistributionnetworkforUtilityfacilityarea throughRMU(RingMainUnit)

8of8

Implementationof11kv/415vpackageSubstationsunitsconnecting11kv networkthroughRMUforstreetLightingandtrafficsignallightings.

ConductRoutineTestsonmaterias&workmanshipasrequired.

Identify,CalibratedandmaintainMasterListofTestingandMeasuring Equipment.

OveralinchargeofElectrical&InstrumentationEngineeringTunnover Department.

Preparationofelectricalcompletionqualitypackageandelectricalmotor testpackages.

Review ofElectrical& InstrumentationQualityPackages9Mechanical completionpackages)

EnsuresthattheQualityPackagesarecompleted.

Ensuresalrequiredsignaturesareinalforms(RFI’SSATICandSATR)

InitiatesRFI’sforreview/approvalofQualityPackages.

AlchecklistsmustbesignedbytheQualityControlInspector.

MonitoringSubcontractorscopeofworkandcoordinationwiththeir Qualityrepresentative’sforinspection&raisingRFIsasperITPsandQCP aspercontractscoeofworks.

Resolvingsitequalityissuesraisedbyclient,byconductingmeetingorin coordinationwithsubcontractors.

ReviewingthesubcontractorMaterialsubmittalspriortofinalsubmission ofdocumentsforensuringalthetechnicaldata’sasperspecificationare compiled.

Assists/PrepareProjectSpecificQualityProcedures,ITPs,Construction MethodStatement,Workinstructionetc.

ConductInspectionandsitevisitinPFCbuilding-Switchgear,andal Electrical&Electro-mechanical&Instrumentationactivitiesonthefield.

PreparationofProjectFinalMCCDossierandtakesapprovalsfromSite ManagementandQualityManagerHOand/orCustomer.

InspectionofInstalationofalInstrumentationcontrolpanelslikeDCS, SIS,FGSandPLCsInspectionactivitiescarriedout.

Instalation ofalinstrumentationpanelslikeDAS(Data Acquisition System),SCADA(SupervisoryControlandDataSystem,Fieldbus,PLCs andLadderProgrammingandFlowComputers.

Instalation of al Telecommunication Field Devices like PA/GA Loudspeakers,Telephones,telephonehandsetsinFAR,CCTVCameras, accesscontroldevices,RadioequipmentandalassociatedJunctionand Marshalingboxesandsupport

FiberOpticCableInspectionactivitycarriedoutasfolowscablelaying, Testing,HookupandTermination.

InspectionofInstalationofcabletrays,cableladder,JBframeandconduit layoutincludingcablepulingandTermination.

Responsibletomaintain(QMS)PQPeffectivelyandefficientlyatSite.

Identifymaterialsources,andinterfacewithengineerfortests,conduct materialtestsandensureconformitywithspecifications&standards

UsedapplicableCompany’sProcedures,WorkInstructionandClient/ Projectspecification(ifany)toperform thejobandmaintainedeffective implementationofISO9001:2008QualitySystem.

PlanandcoordinateforconductofProductQualitychecks&Inspection andapprovalforincomingmaterials.

InspectonsiteandgettingapprovalofRed-linemarkupdrawings.

RaisingtheMCCWalkthroughfordisciplinewiseandfolow-upforclosure 8of8

ofpunchpoints.

Aftercompletionofpunchpointsandfolow-upforclosureofpunchpoints withclientrepresentative.

Assist/PrepareInspection&TestPlanandInspectionSchedule.

PreparationofweeklyandmonthlyQCReportsforclientandMangement.

EnsuretheuseofcalibrationInspection,Measuring&TestingInstruments.

TheREDlinemarksupdrawing,preparingverifyonsiteandgetapproval fromtheclientforfinalsubmission

InspectionTestPlanandchecklistDevalopingandapproxal.

AttendingQA/QCConstructionProgressmenntingwithclient.

MonitoringQA/QCPersonalPerformance.

Supportingmonthly(PQI)ProjectQualityIndex.

InitieatingTechnicalQuary(TQ).

LeadingQA/QCweeklymeetingwithProject/companyQCPersons.

Holding Technicalmeeting withQC Personalto enhance Technical Knowledgeinrespectivedisciplines.

Witnessorperformtestinginaccordancewiththeapprovedprocedures.

Witnssleaktestofimpulsetubeandairlines.

Reviewing and approved ofenergizationprocedureasperproject specifications.

Reviewingandapprovedofsystemwisepackagesforfinalwalkthrough.

Reviewingandapprovedofpreandpostinspectiondocuments.

ReviewingandapprovedofTransformer,PanelEnergizationandMotor soloruntestpackage.

Reviewingandapprovedoflooppackagesforcomplianceandobtaining approvaloffromtheclients.

ReviewingandapprovedofqualifiedTechnicianandtheirCertificates.

MonitoringQA/QCAssistantsandfieldtechniciansPerfomance.

Review ofP&ID,Instrumentspecificationsheet(ISS),InstrumentData sheet(IDS),InstrumentInstalationsheet(IIS),Wiringdiagram,SS316 TubingHookup.

ResposibleforinspectionandreviewalFactoryAcceptanceTest(FAT) reportsofal11kv/415vpackagedunitsincludingprocesscontrolsystem, integratedprocesscontrolsystem,machineryprotectionsystem and safetyinstrumentsystemetc.

PreparationofweeklyandmonthlyQCreportsforclientandmanagement.

Ensuretheuseofcalibrationinspection,measuring&testinginstruments.

TheREDlinemarksupdrawings,preparingverifyonsiteandgetapproval fromtheclientforfinalsubmission.

InPIB(ProcessingInstrumentBuilding)panelslikeIMC(interconnecting Marshalingcabinet),WSC(workstationcabinet)SWC(PIB-switchcabinet), FGS(Fire-gasservecabinet),FGM (FireGasMarshalingcabinet),IPSS

(Intergratedcontrolandsecuritysystem),BPCS9BasicProcessControl System),ESD (Emergencyshutdownmarshalingcabinet),DCM (DCS Marshalingcabinet)carryoutmaterialreceivinginspectionforinstalation asperIFCdrawing.

Reviewingandapprovalofmaterialsubmittalasperprojectapproved manufacturerlistandvendorlistandsupplierlist.

VerifyingrandomlyQA/QCDocumentsandLOGs.

Reviewingandapprovalofthirdpartytestingprocedureasperproject requirements.

Responsiblefortheimplemaintationofqualitycontrolsystem related 8of8

electricalworksaccordancewithprojectspecificationandengineering standards.AsperprojectQA/QC(PQP)planandITPs/

ReporttoQA/QCManagerandProjectManageronthedaytodaybasis. AsprojectQA/QCplan.

Verifyalrequiredinspectionreportandtestrecordsaresystematicaly generatedandcompiledtotheapprovedQCprocedures.

Coordinatewithclientrepresentativesregardingtheimplementationand qualityofworks.

Initiatingproactivenotificationstoavoidfuturecomplicationorviolations.

InitiatinginternalNCR’sforalnon-conformancesintheprojectasper scheduleQ

Coordinatewithclientrepresentativesregardingtheimplimentationand qualityworks.

Preparation ofpreandpostinspectiondocuments,review ofloop packages for its compliance and obtaining approval of the clients/customers.

Initiatingproactivenotificationstoavoidfuturecomplicationorviolances/

Preparationofinspectiontestplanforinstalationandpre-commissining.

PreparationofinspectionchecklistinaccordancewithITPandProject specifications.

Package preparation fortransformer.Panelenrgization and electric motorssolorun.

Preparingexceptionitem list(punchlistitem)foralpendingandno- conformingactivitiesintheproject.

PROJECTINSPECTION:

Inspectionandmonitoringthegroundinginstalations,checktherequired burialdepthandspacingrequirementstoadjacentinstalation,priorto backfiling.(NECArt250,IEEE-80,81)

Substationgroundinginstalationandtesting.asperstandards(IEEE80, NECArt250,SAES)

Lightingprotectioninstalationandtesting.Asperstandards(IEEE,NEC Art250ANSI/NFPA-780,SAES)

NGRinstalationtestingandcommissioning.Asperstandards(IEEE,NEC Art250,SAES)

MV/LVSwitchgearandMCCPanelErection,monitoring,cablerouting, controlpanelwiringandtermination(NEMA,ICS,IEEE-IEC)

LV/MVACandDCMotorinstalation,testingandpreservationasper standards(IEEE-MG,API546,NECart430SAES)

threephaseinductionmotorandGeneratorsinstalationandtesting.As perstandards(IEEE,NECart430&445)

inspectionandmonitoringthecabletrayinstalationasper(NEMAVE1, VE2,IECSAES)

LVLinghtingandpowerpanelinstalationandtesting,asper(NEMA-PB1, NEMA,NECart408,saes,sams)

CathodesprotectioninstalationandtestingofteststationandRTD Sensor,(ICCP),asperstandards9NEMA,NFPA,SAES)/

UPSandBatterysysteminstalationandtesting(NEMA-PE1,5,IECart480, SAES)

Indoor,outdoor,aviation,swimmingpool,shreetlightandgardenlighting instalationandtestinghelipadlighting,rotatingBEACONLight,windsock lightinstalationandtesting.Asperstandards(IESNA-RP-17) 8of8

LV/MVPowerandcontrolcableinstalationandtestingasperstandards

(NETAATS2009,IEEE,NEMA/IECA,NECart320to338)

Ductbank,above/below groundPVCconduitinstalationfiresealing

(NEMA-RN-1,IEC,NECART342,TCB-2,NEMA-TC2,6&8)

HVACPanel,DDCPanelinstalationandfuctionaltestingasperLogic controldiagram.

Transformerinstalationandtestingasperprojectspecificationand standards(IEEE,NECart450,netaats2009saes)

Lv/mvswitchgearandcontrolgearMCC(480v,4.16kv,13.8kv)instalation andtestingCT,PTprotection&managementrelaytesting,breakertesting andpointtopointtestingasperprojectspecificationandstandards

(NEMAICS,NECart460,saes)

IRC,ECM,ECSPanelsinstalationandtermination,looptestandfunctional test.AsperLogiccontroldiagram.

Alarm panel,MV,LVCapacitorPanel,VSDPanel,softstaterinstalation andtesting(NETAATS2009,IEC,IEEE,NEMA)

EectricHeatTracingpanelinstalation,RTD,JunctionBoxinstalationand HeatTracingcableinstalationasper(SAES,IEC,NECart427)

Instalationinspectionoffieldinstrumentssuchastransmitter(Flow, pressure,level,Temperature)Pneumaticinstrumentscontroler(solenoid vales,ON/OFFvalves,atevalvescontrolvalves,thermocouples,oriface plate,venturetube,pressuregauge,vibrationswitchesandcontrolvale positioned)

Glandingandterminationinsoectionofinstrumentcablesatjunction boxestopanelsandmarshalingcabinetsloopchecking,meggeringand continuitytest.

Instalationofinstrumentprocesslinessuchasstainesssteeltubingand galvanizediron.

Inspectionofaltypesofcontrolvalvesbenchcalibrations.

Leadsaninspectionteam forloopcheckingandleaktestactivitiesfor instrumentair/impulslineandpressuretest.

BRIEFSUMMARYOFRESPONSIBILITIESHANDLED:

(PRE-COMMISSIONING,COMMISSIONING AND START UP EXPERIENCE ON FOLLOWINGELECTRICALSYSTEM)

34.5/13.8/4.16KVPowerswitchgearandSF6,VACUUM circuitbreakers

(ABB,Wescosa)

480vAirCircuitBreaker(GE,ABB)-Distributionvoltageoperation.

440/480vLVSwitchgears&MCCwithACBsoperationandMaintainance

(Siemens,ABB,GE)

LV&MC,ACandDCMotoroperationandmaintainance(GE,SIEMENS)

Cathodicprotectionforburiedabdabovegroundlevelpipesracksprocess andUtilitiespipeslines.

ElectricHeatTracingforprocesspipeslinesandvessels.

MV/LVPowerCablesIRTestandHI-Pot(ACVLF/DC)testas(NETAATS 2009,IES-LM-79,80)

FunctionaltestandiluminationorLuxLeveltestingofLightingsystem

(IESNA-RP,ANSI,IES-LM-79,80)

Startupofrelaycontrolpanel,capacitorpanel,softstarter,VFDpanels

CoordinatewithelectricalandinstrumentloopcheckingforIRCPanelload sheddingpanelsthroughDCS.

8of8

CoordinatewithupanddownstreamforintertripFunctionaltest.

Pre-commissioningandcommissionofmotor(MV/LV) soloRuntest, vibrationtest,rotationtest,speedtest(IEEE-841)

Pre-commissioningandcommissionforRelaycontrolpanel,capacitor panelandsoftstarter.

Pre-commissioningandcommissionforHeattracingpanelandsystem

Pre-commissioning and commission for(ICCP)CathodicProtection system,RectifierandControlPanels

Pre-commissioning and commission forMV/LV PowerTransformer 100MVA/25MVA/4.16KV/480V/34.5/4.16KV, 34.5/13.8KV & 13.8/4.16KVDistributionTransformerEnergization(HyundaiandSiemens, Wescosa)asperstandars(NETAASTM)

Pre-commissioningandcommissionforBatteryChargerandUPSPanels Energization

Knowledgefortroubleshootingswitchgear&AC/DCUPS,BatteriesDrives

WorkingknowledgeofSF633KVGIS&AVRPanelsboardsand(100MVA AND25MVA)Powertransformers

DECLARATION:

Iherebydeclarethataltheinformationfurnishedhereinaretrueandcorrect tothebestofmyknowledgeandbelief.

Pandiyamudavath

Date:



Contact this candidate