CAREER PROFILE:

More then 15 Years of work experience as a Senior Bio Medical Engineer

Specialized in Radiology Equipment’s

CT Scan + MRI + Ultrasound + X-Ray Machines+ Fluoroscope, Angiogram + BMD

Lab Equipment’s, Chemistry analyzer + Immunology analyzer + Hematology analyzer + Blood Gas analyzer ABG Machine + Centrifuge,

Others Cardiac Monitors & Defibrillators,

Extensive practical hands-on experience in maintenance medical equipment’s Direct sale of a range of bio-medical products and services, Effective working alone or as a cooperative team member, Professional in appearance and presentation.

ACADEMIC QUALIFICATION : BE. Electronics & Communication (From USA)

TECHNICAL QUALIFICATION

COMPUTERS : Two Year Diploma in computer.

Software & Hardware.

WORK EXPERIENCE

1) ORGANIZATION : ADAN HOSPITAL PROJECT KUWAIT

With CENTRAL CIRCLE CO.

Duration : 2016 to Till Now

Position : Senior Bio Medical Engineer

2) ORGANIZATION : KING ABDULLAH MEDICAL CITY

MAKKAH Saudi Arab KSA.

( JCI ACCREADIATED )

Duration : 1 - 1 - 2012 till 2016

Position : As a Bio-Medical- Specialized Engineer.

3) ORGANIZATION : KING SAUD MEDICAL CITY

Riyadh Saudi Arab KSA.

(CBAHI & JCI ACCREADIATED)

Duration : 21 – 01 – 2007 to 03 – 12 - 2011

Position : As a Bio-Medical-Engineer.

4) ORGANIZATION : Sultan Qaboos Hospital

Salallah Sultanate of Oman

Duration : 15 - 12 - 1997 to 26 – 01 - 2002

Position : As a Bio-Medical- Technologist.

Duty Responsibility :

MEP, VSA, MST Details of medical equipment’s as per specification.

. Constructing data analysis for new medical equipment for hospital project according to the tender/execution documents such as drawings, Specification, BOQ and prime documents.

. Analysis of the specification for medical equipment’s with client requirement.

. Preparing the MEP value engineering options.

. Assist in reviewing and commenting on subcontractors drawings and reports.

. Analysis of drawings to ensure that it comply with applicable guidelines / regulations.

. Ensure technical compliance and functionality at set level of quality.

VSA & MST : Details about medical equipment’s as per MOH approval.

Check all medical equipment’s while installing as per tender contract of MOH requirement. Check all electrical socket and central AC & Plumbing work all departments of hospital.

* SPECIALIZED IN RADIOLOGY EQUIPMENT.

I have worked on the 1000 MA X-ray Machines with fluoroscope with multi formed camera.

Model : Prestige 1000 MA

Model : Medio 50 CP

Model : Medio 65

Model : Yiso

MANUFACTURERS : GE + PHILIPS + SIEMENS

ROUTINE MAINTENANCE & COMMAN PROBLEMS.

Check the collimator + collimator plates front & back up & down.

Collimator light & centering position.

Buckeye & cassette tray + cassette tray lock & wall buckeye calibration of tube.

* COMPUTER TOMOGRAPHY (CT Scan)

I have worked on GE + PHILIPS + SIEMENS.

GE : High Speed 16 Slices

Discovery HD 750 128 Slices

PHILIPS : Brilliance 64 Slices

Siemens : Sam tom Definition AS 128 Slices

ROUTINE CHECK UP.

Warm up the tube + check table couch + Gundry + Table height + clean.

Artifact belongs to tube & modules.

PERIODIC PREVENTIVE MAINTENANCE (PPM)

Check the couch

Check Patient Table ( While doing scan table will shake for slices )

Check Table moments UP & Down Front & Back

Check Gundry detector Cover

Check tube cooling & cooling fans.

Check detector

Check 3 phase motor.

Check hard disk & patient disk.

Check gantry.

Check artifacts (Artifacts belongs to tube & DMS modules)

Check DMS (Data measurement system)

Check IRS ( Image resources system )

Check ICS (Image control system)

Check console unit.

Check high tension cable.

Calibration with fun top.

Clean complete unit.

* Magnetic Resonance Imaging (MRI)

Mfg. G.E & + Siemens

GE Sighna HD 1.5 Tesla

Siemens Magnitoum 1.5 Tesla

Siemens Skyra 3 Tesla

RF + MAGNETIC SHIELD.

Normally COOPER & GALVANISE SHIELD is using for MRI 1.5 T 63. MHZ

3. T 127 MHZ

Magnetic shield using for abnormal side and small room only pacific shield.

There are two type of magnet.

(1) Super coil magnet : Need helium work with helium

(2) Permanent + open Magnet : No need helium it will work with only magnet. This magnet work with with out helium.

But it will take more time to Scan for all cases.

Magnetic room.

If there is need any emergency shout down in magnetic room.

Press conch baton inside magnetic room all helium will go out through vent pipe.

Vent pipe is connected with machine to go helium out.

while helium discharges out time we can cot stand in the room because very cold .270 degrees will be.

After this we cannot use machine until refile helium + Magnetic and machine software reinstall.

Console operating side :

Press emergency red baton to of machine.

ROUTINE CHEEKUP:

Cheek Helium Pressure 0.9 to 1.9 & Helium level 70 to 100 /.

Cheek room cooling temperature, Machine & control room,

Wither A\C working or not.

Check Chelir and water level

Cheek patient table.

Cheek all coil, nee coil, head coil, body coil, Spain coil,

Cheek all machine key functions.

Cheek RF rectifier.

Radio Frequency Power Amplifier (RFPA)

Check Gradient Power Amplifier (GPA)

Check Electronic Power Cabinet (EPC)

Check Water Interface Panel ( I F P )

Check Alarm Box

Check Fire Monitor (VLM)

Check UPS

Check Emergency Power Switch

Check Magnet Quench Button.

Check Cold Head

Check Heat Exchanger

* ULTRA SOUND SCANNER.

I have worked on GE + + SIEMENS + PHILIPS

Manufacture: GE + SIEMENS + PHILIPS

Model : GE Logic E4 E5 E8 E9 + Logic 4, 5, :

SIEMENS + ACUSON X 30

ROUTINE MAINTENANCE & COMMAN PROBLEMS.

Check key board & clean.

Check track boll (position of boll right & left up & down moment).

Check date & time.

Check the printer.

Check the transducer.

2.5 MHz 3.5 MHz

2.7 MHz 5.7 Mhz.

* CARDIOLOGY EQUIPMENTS,

PATIENT MONITOR,

I have worked on cardiac monitors

Manufacture: HP + GE + SIEMENS + DINAMAP

DRAGER + MINDRY

Routine cheek up & common problems.

Cheek the power cable & connection.

Cheek the battery & connection.

Cheek the ECG cable & leads + patient electrodes.

Cheek the ECG wave with stimulator.

Cheek the spo2 sensor & extension cable.

Cheek the NIBP house assembly & cuff.

Cheek the temperature cable.

Cheek the battery.

Cheek the power supply and connection of cable.

Do PPM according the maintenance shad owl.

* DEFIBRILLATOR,

There are two type of defibrillator monophasic + Biphasic.

Monophasic: it will work on one single direction while given shock.

Biphasic: it will work on two directions while given shock it

Will go & Come back reveres direction.

Manufacture : PHILIPS + LIFE PACK + GE

Model : Heart start XL, Life pack 9,11, GE 800

Routine cheek up & common problems.

Cheek the power cable & connection.

Cheek the battery voltage & connection.

Always keep for charge because we are given DC SHOCK

to the patient heart.

Cheek the defibrillator on battery working or not.

Cheek the ECG cable & leads.

Cheek the printer & printer assembly.

Cheek the paddles & paddles connections.

Cheek the adult & neonatal paddles.

Always keep clean to paddles.

Cheek the charge button.

Cheek the shock button.

Cheek the joules' rotating knob.

Cheek the joules energy

While daily checking selects 10, 50, 70, 100 joules and give shock.

Cheek the printer.

Cheek the date & time.

Cheek and calibrate with defibrillator analyzer.

Always keep clean.

Do PPM according to the maintenance shadow.

* EXTRA CURRICULAR ACTIVITES.

* Participate, visit and inter-act in the various seminars conducted related to BIO – MEDICAL - ELECTRONICS.

* Show continuing interest in reading journals.

* PERSONAL STRENGTHS:

I regard myself as an innovative, hardworking, efficient and ability to work in lengthy working hours alone or as team member.

PERSONAL PROFILE

NAME : MOHAMMED YASEEN

FATHER NAME : MOHAMMED ISHAQ

DATE OF BIRTH : 07 – 07– 1985

MARITAL STATUS : MARRIED

RELIGION : ISLAM

NATIONALITY : INDIAN

LANGUAGES KNOWN : ENGLISH + ARABIC + URDU

PASSPORT DETAILS:

PASSPORT NUMBER : U5646331

DATE OF ISSUE : 23 – 3 - 2020

DATE OF EXPIRY : 22 – 3 - 2030

PLACE OF ISSUE : Hyderabad

DRIVING LICENSE : VALID KUWAIT DRIVING LICENSE

PERMANENT ADDRESS : H.NO. 17- 3 – 169

RAIN BAZAR YAKUTPURA.

HYDERABAD INDIA.

TEL NO : 91-738******* +934*******

Cell NO : 968 - 96011557

E-Mail : adskin@r.postjobfree.com

adskin@r.postjobfree.com



Contact this candidate