B.Manikandan Mobile: +91-960*******
Mobile: +968-********
Email: *.**************@*****.***
A Dynamic & Multi skilled Professional Experience of above 12 - Years in AIS & GIS in 230/110/33/11 KV & 110/11KV/.415V and 110/11KV/.433V Substation Operations and Maintenance, and also Transmission & Distribution lines.
C- LICENCES HOLDER
C- LICENCES NO: C- 44129
(Valid 09.01.2022 To 08.01.2026)
OMAN- DRIVING LICENCES
LICENCES NO: 109278595 (Valid From 21.01.2021 To 21.01.2023)
PASSPORT NO : V3865991
(Valid From 01.12.2021 To 30.11.2031)
APPLIED POST FOR : ELECTRICAL MAINTENANCE ENGINEER
EDUCATIONAL QUALIFICATION
Professional course : B.E - Electrical and Electronics Engineering
Institution/University : LCR College of Engineering and Technology
Kanchipadi, (Chennai)
Year of Pass : April 2011
Percentage : 66 %
Professional course : DEEE - Electrical and Electronics Engineering
Institution/Dote : John Bosco Polytechnic,
Thiruvallur, (Chennai)
Year of Pass : April 2006
Percentage : 75 % with First Class
Educational Qualification : +2 GOVT.HIGER SECONDRY SCHOOL,
Year of Pass : March 2004
Avadi, (Chennai)
Percentage : 55%
Educational Qualification : 10th P.J.GUPTHA HIGH SCHOOL,
Ambattur. (Chennai)
Year of Pass : March 2002
Percentage : 67%
OMAN SHAPOORJI COMPANY L.L.C From 04.12.2016 To Till Date
ELECTRICAL SUPERVISOR
RESPONSIBILITIES OF WORKS :
Knowledge on working of all electrical equipment like EHT,HT & LT Lighting earthing system HT & LT motors and switch gears their operation and maintenance trouble shooting route cause analysis
Capable of regular maintenance of the plant during emergency breakdown and manual maintenance of the plant.
Daily inspection to the area of responsible to check the healthy and normal working condition of the equipment.
Maintenance and operation of the transformer Diesel Generator chiller Ups and Firefighting System.
Ability to read and understand electrical equipment drawing and manual.
Planning and execution of annual maintenance of work.
Ensure all the maintenance work carried out systematically effectively and safely
Improving existing preventive maintenance system thus reduce maintenance cost and improve performance of equipment.
Allocation of the work to the technicians and monitoring it.
Following up the work completed status and work in progress details to the next shift.
Operation & Maintenance Of sub Station and the same effective Start Up and Shut down of the plant equipment’s accordance with the standard operating Procedure and work instructions.
11KV/.433V Substation Operation & Maintenance of with using 1000 KVA Distribution Transformer with control SF6 RMU system and SF6 Breakers and VCB,ACB,CT, PT and etc.
Operation & Maintenance of 11KV 4000KVA & 2275KVA Caterpillar DG-Sets with AMF Control and Auto Synchronization control with NGR.
Swimming pool Operation & Maintenance of Water Heater Thermolic and Astra pool (108 KW&72 KW ) fault find out and troubleshooting.
Plant Room related Cold water Booster pump Hot Water Circulation pump water heater AO Smith ( 18KW,12KW,6KW & 4 KW ) SPS Pump, AHU,FAF,EF control panel complaint attending and trouble shouted.
Preparation of Daily, weekly and monthly report, Shift Schedule PPM & BD report preparing and check list preparing etc.
Day to day Help Desk, Preventive Maintenance Break down Maintenance attending and troubleshooting updating to through SMART FM.
Day to day Planning Maintenance of man power, preventive maintenance, Co-ordination with Other departments etc.
VOITH INDUSTRIAL SERVICES INDIA PVT LTD From 12.02.2015 To 03.12.2016
( 1 Year-10 Month )
CHENNAI PETROLEUM CORPORATION - CPCL
Electrical Team Leader
RESPONSIBILITIES OF WORKS :
Refinery Area Ex Zone Electrical Maintenance of site equipment.
Daily inspection to the area of responsible to check the healthy and normal working condition of the equipment.
Maintenance and operation of the transformer Diesel Generator chiller Ups and Firefighting System.
Ability to read and understand electrical equipment drawing and manual.
Planning and execution of annual maintenance of work.
Ensure all the maintenance work carried out systematically effectively and safely
Improving existing preventive maintenance system thus reduce maintenance cost and improve performance of equipment.
Allocation of the work to the technicians and monitoring it.
Following up the work completed status and work in progress details to the next shift.
110/11KV Substation Operation & Maintenance of with using 25 MVA Power Transformer SF6 Breakers and VCB,ACB,CT, PT and lightening arrester etc.
Operation & Maintenance Of sub Station and the same effective Start Up and Shut down of the plant equipment’s accordance with the standard operating Procedure and work instructions.
Operation & Maintenance of 9 Substation of 11KV/433 V it’s a Ring Main Substation which involves 2500 KVA step down Transformers, which use the Breakers of VCB, ACB, APFC panels,Battery charger etc.
HT CT Ratio (800/600/300/150/1A) & LT CT Ratio (4000/5A1000/5A) and PT 110KV/110V and 11KV /110V.
Annual plant Maintenance Shutdown activities
Capable of guiding/leading the electrical maintenance team and implementing the best maintenance practice for the plant including High voltage of 11 KV systems.
Operation & Maintenance of 415V 250 KVA, 500 KVA and 1250 KVA DG Gen Sets with AMF Control.
60KVA, 80KVA, 120KVA, and 160KVA UPS Maintenance.
Chiller-75TR,150TR,260TR,300TR, AHU,TFA Operation and Maintenance.
HVAC & 1500 CFM Air compressor and all Electrical System analyze and Energy saving process Implementation
AMC Planning and Vendor Co-Ordination Preventive and Break down Maintenance
Day to day Energy Consumption updating and Documentation work.
Tamil Nadu Electricity Board at Tharamani From 05.02.2014 To 04.02.2015
Graduate Trainee Engineer ( 1 Year)
Operation & Maintenance of 230/110/33/11 KV AIS Switch Yard and Load maintain the Sub Station.
Shift Involved in Sub-station operation works and load distributive of various load
230KV Load, 110KV Load
33KV Load, 11KV Load
Work involved in Breakdown Maintenance and Trouble shootings are equipments.
used in 100MVA Auto Transformer,50 MVA,25 MVA,16 MVA,8 MVA Power transformer & 350,250KVA Distribution Transformers
2000A SF6 breaker,1250A VCB and also used control breakers are ACB,MCB,MCCB,ELCB,MLP and DCDB etc.
Operation & Maintenance of 25 KVA DG Gen Set .
Current transformer and Potential Transformer are used for protection purpose and measuring purpose and also used for equipment safety protection used in lightening arrester (LAS).
Switching operation & Maintenance of Transformer, Circuit Breaker, CT, PT, LAS and Relay panel.
TESTING :
1.Transformers
2.CT
3.PT
4.Breaker
INPLANT TRAINING DETAILS :
I have Training Attended in 230KV/110KV GIS Sub Station at KOYAMBEDU METRO RAIL.
I have Training Attended in 230KV/110KV/33KV GIS Sub Station at MYLOPORE.
I have gone INPLANT TRAINING in THERMEL POWER PLANT at ENNORE.
SUB STATION TRAINING DETAILS
Concern Name : Sriperumbudhur TNEB
(400/230/110KV SUB STATION)
Concern Name : Alamadhi TNEB
(400/230/110KV SUB STATION
Concern Name : Koyambedu TNEB
(230/110KV GIS SUB STATION
Concern Name : Basin Bridge TNEB
(230/110KV SUB STATION
Concern Name : KORATTUR TNEB
(230/110KV SUB STATION
Concern Name : PADI TNEB
(110/33/11KV SUB STATION
Concern Name : PATABIRAM TNEB
(110/33/11KV SUB STATION
Sodexo MacClellan Integrated services India Pvt Ltd
L &T Shipbuilding site 23/12/2013 to 03/02/2014
SHIFT ENGINEER (2 Month)
Operation and Maintenance of 1 No’s MRS 33/11KV Sub Stations which used in
6.3 MVA Transformer, 33/11 KV VCB,CT, PT and lightening arrester etc.
Operation and Maintenance of 7 No’s 11KV/ 433V Sub Stations it’s a Ring Main System which involves 2MVA transformer, VCB’s, ACB’s, APFC panels, Battery Charger ect.
Operation maintenance of 11KV HT 2MVA & 1.25MVA DG System.
80KVA,120KVA,and 160KVA UPS Maintenance.
Air compressor and Drier Kaiser and Champion Make .
Screw compressor Flooded Evaporator type Chillers Career make.
Day to day Energy Consumption updating and Check list updating work.
Preventive and Break down Maintenance
Day to day Planning Maintenance of man power and Co-ordination with Other departments etc.
MacClellan Integrated services India Pvt Ltd
Nokia India Pvt Ltd 07/06/2011 to 22/12/2013
JUNIOR ENGINEER (2Year 6 Month)
Operation & Maintenance of 110/11KV Substation with 40MVA Power Transformer 110/ 11 KV SF6 Breakers and VCB,CT, PT and lightening arrester etc.
Operation & Maintenance of 4 Substation of 11KV/415 V it’s a Ring Main Substation which involves 1600KVA step down Transformers, which use the Breakers of VCB, ACB, APFC panels,Battery charger etc.
Operation & Maintenance of 415V 2000KVA x 7 No’s Caterpillar DG-Sets with AMF Control.
CPS PILLAR Make 1670KVA It’s a Dynamic UPS and also used Static UPS 160KVA-120KVA,60KVA
HT VCB (1250 &3150 Ampere) & LT ACB(2500,3200 &5000Ampere)
HT CT Ratio (800/1A) & LT CT Ratio(1000/5A)
Air compressor and Drier Kaiser and Champion Make
Screw compressor Flooded Evaporator type Chillers Career make
AMC Planning and Vendor Co-Ordination.
Preventive and Break down Maintenance
Day to day Energy Consumption updating and Documentation work.
Day to day Planning Maintenance of man power, preventive maintenance, Co-ordination with Other departments etc.
TVS LUCAS –LTD 30.01.2007 to 14.07.2008
(1 year 6 Month)
Technician Apprentice:
Job Responsibilities : ALTERNATOR BUSSINES UNIT
(Production of Alternator’s Rotor Assembly Department)
Chennai, Padi
SCHNAIDER ELECTRIC
05.07.2006 to 22.12.2006
Short term Trainee : (6 month)
Job Responsibilities : MCB Single pole, Double pole, Three pole, Four breaker and Isolator Breaker Assemble Department
pole
Chennai, Pattravakkam.
DOCUMENTATION WORK:
Paper presentation
Weekly Report
PM Check Sheet
Daily Consumption updating
AREAS OF INTEREST:
Transmission and Distribution
Power System
Power plant
Electrical Machines
Designing in Electrical CADD
Power Electronics
COMPUTER SKILL:
MS-Office
Tally9
Hardware & Networking
Windows -Xp
Windows-7
Operating System Installation
Software Installation
Trouble Shooting
Diploma in Electrical CADD
Auto Cad - 2004
Foundation in electrical CADD
Auto Cad - 2010
CADian
PCschematic Elautomation
Or CAD
OrCAD Capture
Or CAD PSpice simulation
Or CAD PCB Editor
PERSONAL DETAILS
Name : MANIKANDAN B
Father’s Name : BASKARAN P
Mother’s Name : MALLIGA B
Date of Birth : 05-06-1987
Sex : MALE
Nationality : INDIAN
Marital status : MARRIED
Known Languages : ENGLISH, TAMIL,HINDHI,ARABIC
Permanent Address : MANIKANADAN B
NO.28 KANNIMOOLA GANAPATHY STREET,
AMBATTUR,
CHENNAI - 600062.
Declaration:
I hereby declare that the above mentioned information’s are true to the best of my knowledge and belief.
Date:
Yours Sincerely
Place: Chennai B.Manikandan