Post Job Free

Resume

Sign in

Quality control, inspection, project management team, utility and Chie

Location:
Longview, TX, 75605
Posted:
September 01, 2022

Contact this candidate

Resume:

ADAM “TOMMY” ELIZONDO, JR.

*** ****** ******

Longview, Tx. 75605

Cell: 361-***-****

adsd7f@r.postjobfree.com

Objective: Employment in a field that allows me to provide great work ethic as a conscientious employee moving forward safely while reaching new goals to comply with company demands

PROFESSIONAL EXPERIENCE

Primoris Services Corporation, Carlsbad, New Mexico

December 2019 to October 2020

Customer: XTO

Duties: Project management team. Assigned to capture all extras (adder sheet) in the field throughout the projects. Getting signed off and approved by the lead inspector on site.

HGA, Ruston, Louisiana

October 2018-August 2019

Customer: Reliance Gathering

Contractor: GTO, George West, Texas

Duties: Inspection of row clearing, stringing of pipe both poly and steel, mainline welding, coating crews, lower in and tie in crews, backfill and cleanup of rows. And final cleanup and restoration.

Epic Management, Houston, Texas

October 2017-October 2018

Customer: Halcon Resources

Contractor: Epic Energy Services

Duties: Inspection of field survey crews, inspection of clearing row’s, stringing of pipe both steel and poly pipe. Fire line inspection, and following crews, ditching, lower in, coating, tie in crews, backfill and finishing crews on high and low pressure lines for water, oil and gas. Also inspected on facility sites for hookups to live lines, dealing directly with the project management of the customer, Halcon resources.

HGA, Ruston, Louisiana

October 2016 - August 2017

Customer: En-Link Pipeline

Contractor: New Mexico Rentals/Crossfire

Duties: Inspection of ditching crew/lower in crew/backfill. Following landowner agreements for depths, Separation of new and existing limes and/utilities. Topsoiling of property. Excavation of existing hotlines. Coating and coating repairs. Tie ins and restoration of ROW.

QIS, Guymon, Oklahoma

September 2015 - April 2016

Customer: Williams/Transco

Contractor: Jendal Steel mill

Duties: Final inspection bench in steel mill and final inspection bench of coating mill.

Applied Consultants, Longview, Texas

August 2014 - July 2015

Customer: American Midstream

Contractor: Multiple contractors used in building gathering system

Duties: Senior chief over multiple jobs running simultaneously (up to 10 projects at running at times). Up to 34 inspectors in the field and yard at once. Duties were watching over all construction projects daily, directing placement of inspection daily and accordingly, taking all reports and compiling into master report. Conducted daily morning meetings at 6am with all inspectors and office employees.

Wood Group/Mustang Eng., Houston, Texas

March 2014 - May 2014

Customer: Dow Chemical

Contractor: Troy

Duties: Inspection of ditching crew/lower in crew/backfill. Following landowner agreements for depths, Separation of new and existing limes and/utilities. Topsoiling of property. Also hdd crews For several hdd and slick bore projects.

Wood Group/PAC Houston, Texas

Nov 2013 - Feb 2014

Customer: Murphy Oil

Contractor: Duphil and Coastal

Duties: Inspection duties varied from start of job to finish. Clearing of ROW, stringing of pipe,

Fire line, HDDs, hydro tests, ditching and lower in, tie in crews, coating crew, fab and bolt up/torque, painting, and

Clean up

Wood Group/Mustang Eng., Houston, Texas

March 2010 – August 2013

Customer: Chief Oil & Gas/PVR

Contractor: Numerous contractors building gathering system pipelines

Duties: Assistant Chief Inspector, Inspection of complete start to finish jobs.

Ranging from, 2” to 24” pipelines

Compressor installation in compressor stations

TGCS Energy Services, Houston, Texas

Feb 2009-May 2009

Customer: Enterprise Prod.

Contractor: Strike Const. and Wild Horse Const.

Duties: Inspection of process of running cleaner tools in variety sizes of pipeline. On lines up to 24”, the inspection of, and the tracking of the ILI tool runs, while completing all reports of time, pressure, product flow, and completion of the ILI runs including step by step photos. Also performed, inspection of pressure charts, weather chart, time charts for the hydro-tests ran on Enterprise lines, above ground and below.

Universal Ensco Inc. Houston, Texas

May 2008-October2008

Customer: Trans Canada

Contractor: Henkel & McCoy

Duties: Inspection of the prep and application of field girth weld coating using SPC 2888. Inspection of crew running holiday detector on both the girth welds coated in the field, and, the original FBE coating on the body of the pipe, while on skids, and before lower in of the pipe.

I also performed the inspection of tie-ins at road and water crossings. Inspection of the lower in crew, and the back-fill crew was also performed.

Mustang Eng., Houston, Texas

August 2006-May 2008

Customer: Enterprise Prod.

Contractor: Weatherford (cleaned line), Strike Const. (completed project)

Duties: Coating Ins./Utility Ins. new construction and rehab of pipeline (10” and 8”)

Inspection of all excavation,, and road drill sites, coating of girth welds and underground fabrication, also, the complete restoration done on the right of way.

Mustang Eng., Houston, Texas

March 2005

Customer: (location) Freeport LNG

Contractor: Zachary

Duties: Coating Inspector, all girth coating and coating of fabrication of 42” and 36” pipe

Quality Inspection Services, Inc., Goodwell, Oklahoma

August 2004

Customer: Unisource Energy Services

Contractor: Pacific Industrial Pipeline Co., Inc./Northern Pipeline

Duties: Inspection of joining polyethylene pipe and fittings by electro-fusion based upon gas company Standards and Procedures manual including: fusion times, measurements, pressure tests, and hot taps. Visual inspection of wells on low pressure steel gas lines, fittings, and transition pieces (steel to PE) installed for main and services. Inspection of installation of natural gas main and service lines including: clearance of existing structures, reviewing coordinates and footage according to as built presented by engineer, pressure tests, and hot taps. Also performed the inspected the abandonment and replacement of existing lines. Inspect contractor excavation and backfill including: trench depth, width, bedding and shading, and complete backfill for gas lines across private property, county roads, and highways.

Materials Consulting Services, Inc., Houston, Texas

May 2004

Customer: Williams Transco

Contractor: Acipco Steel, EB Foster Coating; Birmingham, Al.

Duties: (Steel) Final inspection of ERW pipe. I also performed the inspection of OD coating both FBE and ARO. Walkthroughs were done hourly throughout EB checking on line speed, blast profile, oven temps, coating temps, and total mils.

Materials Consulting Services, Inc., Houston, Texas

February 2004-May 2004

Customer: Williams Transco/Gulfstream Project

Contractor: Berg Steel, EB Coating; Panama City, Fl.

Duties: (Steel) Final bench inspection of 30" DSAW pipe .441wall. Dimensional and visual inspection was done along with walkthroughs throughout Berg Steel. Inspections of OD FBE coating, along with, inspection of stations during the coating process.

Quality Inspection Services, Inc., Goodwell, Oklahoma

August 2003-February 2004

Customer: Unisource Energy Services

Contractor: Pacific Industrial Pipeline Co., Inc./Northern Pipeline

Duties: Inspection of joining polyethylene pipe and fittings by electro-fusion based upon gas company Standards and Procedures manual including: fusion times, measurements, pressure tests, and hot taps. Visual inspection of wells on low pressure steel gas lines, fittings, and transition pieces (steel to PE) installed for main and services. Inspection of installation of natural gas main and service lines including: clearance of existing structures, reviewing coordinates and footage according to as built presented by engineer, pressure tests, and hot taps. Abandonment and replacement of existing lines. Inspect contractor excavation and backfill including: trench depth, width, bedding and shading, and complete backfill for gas lines across private property, county roads, and highways.

Quality Technical Consultants Inc., Harvey, Louisiana - 2003

Customer: Chevron, Total Fina Elf/Matterhorn Project

Contractor: Coflexip-Stenna Spoolbase, Theodore, Alabama

Duties: Inspected 8" and 10" FBE girthweld coating, thermal spray aluminum coating and repairing, thermal spray polyethylene coating and repairing, yard repairs of coating and spooling of 8" and 10" stalks.

Quality Inspection Services, Inc., Goodwell, Oklahoma - 2002

Customer: Williams Transco/Kern River Expansion

Contractor: Napa Pipe, Midwestern Coating; Napa, California

Duties: Final bench inspection on 30" and 36" DSAW pipe; Complete and thorough dimensional and visual inspections were performed on various wall sizes and steel grades; Walk-through checks were performed daily throughout the steel mill; Other inspections were performed on O.D. and I.D. FBE and ARO coatings and double end girth weld coating.

Quality Inspection Services, Inc. Goodwell, Oklahoma- 2002

Customer: Williams Transco/Kern River Expansion

Contractor: Stupp Steel Mill; Baton Rouge, Louisiana

Duties: Final bench inspection of 24" ERW pipe.

Quality Inspection Services, Inc. Goodwell, Oklahoma - 2002

Customer: Williams Transco/Kern River Expansion

Contractor: Bayou Coating; Baton Rouge, Louisiana

Duties: Inspection of O.D. FBE coating

Quality Inspection Services, Inc. Goodwell, Oklahoma - 2001

Customer: Williams Transco/Gulfstream Project

Contractor: Bredero Price Company; Ft. Meade, Florida

Duties: Final inspection of concrete weight coating

Quality Inspection Services, Inc. Goodwell, Oklahoma - 2001

Customer: Williams Transco/ Gulfstream Project

Contractor: Bredero Price Company; Mobile, Alabama

Duties: Final inspection of concrete weight coating- concrete thickness ranged from 2.75" up to 5"; Inspections on the installation of anodes and buckle arrestors on approximately 3500 pieces of 36" pipe; Inspection of gunnite repairs on concrete coating and two-part repairs on FBE prior to concrete coating; and witnessing and recording daily proctor tests on concrete cylinders.

CERTIFICATIONS AND EDUCATION

High School Diploma- Carthage, Texas

AOC's, General Pipeline/NCCER certs

O.Q. Certs: Controlling accidental release of natural gas, purging, control of static electricity, patrolling and system surveillance, valve maintenance, locating and marking facilities, joining steel pipe, joining plastic pipe, pressure testing, installing steel mains and services, installing plastic mains services, abandon and reinstate facilities, capping pipe lines, cathodic protection, installation of excess flow valves, inspection, corrosion control

REFERENCES

Hunter Phillips-903-***-****

Robert Riley- 337-***-****

Jim McCartney- 970-***-****

Mike Kitterlin- 318-***-****

Mike Culpepper- 318-***-****



Contact this candidate