Post Job Free

Resume

Sign in

Energy Management Maintenance Manager

Location:
Dayton, OH
Posted:
August 17, 2022

Contact this candidate

Resume:

Phillip Eshbaugh

*** * ********* **

Pitsburg Ohio 45358

Phone:

Cell: 937-***-****

E-Mail: adr6rl@r.postjobfree.com

Professional Summary

To secure a position within a Company that will allow me to perform to the best of my ability. Detail-oriented Quality Services with strong educational background in Building Maintenance, supported by field research and professional work experience in facilities maintenance. Director and Facilities Manager with more than 28 years managing and supervising both residential and commercial facilities. Confident team player and natural leader.

Skills

Performance optimization

Expertise in troubleshooting

Creative problem solving

Excellent customer relations

Design review

General contracting professional

Interior and exterior renovation

Project scheduling

Building systems and services

Work History

November 2016 to current

Maria Joseph Living Care Center 4830 Salem Ave Dayton Ohio 45416

Director of Maintenance and Security and Plant Operations. For 288 bed Health Care Campus.

Responsible for all Building and Grounds Operations including Boiler plant operations and Maintenance

6 Hot water Boilers and 2 low pressure steam boilers and pumps.

All Electrical Plumbing HVAC Including Chillers, also responsible for all Life safety under Federal and State Guidelines including but not limited to Fire Alarm systems Sprinkler systems Nurse Call Wander guard/Alert systems energy management systems etc. also responsible for continuous NFPA 99 and other NFPA99 standards adopted by Federal and State Guidelines.

Also responsible for all building contract work and inspections including elevators, Back flow preventers Boilers and any other contract work involving Building Maintenance.

Also responsible for Computerized energy management system

June 2014 to 2016

Village Green Health Campus 1315 Kitchen Aid Way Greenville, OH 45331

Director of plant operations

Responsible for all building operations and standards set by Trilogy and the State Of Ohio including life safety, fire alarm system, sprinkler system, electrical and lighting, boilers and water heaters, PTAC's, nurse call systems, communication systems, wonder guard door checks, generator test and inspections, lighting and energy management systems and more.

Also in charge of documentation of all operations environmental

Also took charge of creating construction punch list during the building finalization and followed through till opening then started new punch list for 1-year warranty

Maintained and tested fire alarm systems.

Consistently updated knowledge of safety requirements and policies.

Measured devices, including analyzers, amp meters and volt-ohm meters.

Maintained a working area that was clean, safe and stocked with appropriate equipment and supplies.

Checked, tested and replaced faulty components, circuit modules and printed circuit boards.

Installed HVAC systems, building control systems, general office equipment and furniture.

Changed filters on all HVAC equipment.

Maintained and repaired boilers, chillers, air handlers, DIW, IWW, scrubbers and closed-loop systems.

November 2012 to September 2017

Village of Hollansburg, OH 45332

Councilman

Currently playing a key role in the community as a Councilman, assisting in the safety and comfort of our resident's and currently playing a key role in the installation of the new sewer project working with surveyors and state EPA officials. Also, part of a code enforcement team to help with the Village beautification and safety system and in charge of assigning work to town employees.

Managed tool shop, monitored stock levels and ordered parts.

Directed operation and maintenance of building mechanical and utility systems.

Documented all maintenance and repairs.

Conducted preventive and corrective maintenance on bearings, pumps, shafts and fans.

Completed emergency service of diesel generators.

Repaired air handlers and makeup air units.

Referenced blueprints, repair manuals and parts catalogs for complex repairs.

Repaired defective equipment parts.

Followed routine and preventative maintenance checklists.

Inspected drives, motors and belts.

Installed pipe systems and plumbing.

Diagnosed mechanical problems and determined the best ways to correct them.

June 2011 to June 2013

Grubb & Ellis Miamisburg, OH

Building Engineer

In charge of lighting, plumbing, electrical, HVAC boilers, building automation system and responsible for budget.

Maintained and tested fire alarm systems.

Consistently updated knowledge of safety requirements and policies.

Planned motor starter and control installations using codes and specs.

Demonstrated expertise in the use of cable reels, stripping tools, voltage detectors, crimping tools and wire and cable cutters.

Operated systems such as Andover Energy Management Systems and computers.

Maintained a working area that was clean, safe and stocked with appropriate equipment and supplies.

January 2005 to June 2013

Rapid Maintenance & Engineering 122 N Jefferson Pittsburg Ohio 45358

Senior Maintenance Manager

Responsible for contracted properties.

And ensuring all special projects were completed.

Also inspected HVAC systems on contracted properties and performed predictive maintenance at contracted properties. Worked with PLC systems and replaced boards and installed programs.

Was also involved with seasonal chiller start up and boiler shutdown and start up. Scheduled work with contractors so it wouldn’t interfere with production.

Played key role in designing a program to lower power consumption for an energy management system that resulted in an additional 15% reduction yearly

Installed, tested and modified circuit breakers, controls, fuses, lights and motors.

Fabricated specific electrical component parts and assemblies.

Interpreted drawings, wiring diagrams, flow charts and written descriptions of the project requirements.

Worked with various types of cableways, conduits and other electrical raceways.

Updated service record files on equipment drawings and history.

Recorded the respective measurements for each project.

Worked extended hours on weekday and weekend projects.

Maintained and tested fire alarm systems.

Consistently updated knowledge of safety requirements and policies.

Planned motor starter and control installations using codes and specs.

Demonstrated expertise in the use of cable reels, stripping tools, voltage detectors, crimping tools and wire and cable cutters.

Developed in-depth knowledge of arc flash ratings and standards.

Measured devices, including analyzers, amp meters and volt-ohm meters.

Operated systems such as Andover Energy Management Systems and computers.

November 1985 to December 2005

Quality Services 114 Home Ave Dayton Ohio 45404

Director of Operations

Was responsible for all day to day operations and testing of equipment on contracted properties. Also responsible for 28 employees and their equipment, including company owned trucks. Worked with factories on scheduling maintenance during plant shutdown, setting new equipment and start up. Assisted with programming and setting up a PM schedule also was responsible for doing predictive maintenance.

Installed, tested and modified circuit breakers, controls, fuses, lights and motors.

Fabricated specific electrical component parts and assemblies.

Worked with various types of cableways, conduits and other electrical raceways.

Updated service record files on equipment drawings and history.

Consulted with the supervisor electrician regarding the likely risks associated with the assigned job.

Consistently updated knowledge of safety requirements and policies.

Planned motor starter and control installations using codes and specs.

Scheduled all contractors and materials deliveries.

Trained and promoted continued education for all onsite crew members.

Performed load calculation for sizing wire and circuit protection.

Collaborated successfully with cross-functional development teams to design and manufacture new products.

Wrote protocols, qualification documents, test plans and test reports for quality assurance purposes.

Repaired and replaced plumbing parts, including fixtures and drain lines.

Changed filters on all HVAC equipment.

Re-keyed facility locksets, including electromechanical locksets.

Programmed and replaced CCTV systems, including cabling, cameras, DVRs and power supplies.

Monitored and maintained heating, ventilation and cooling systems.

Monitored data center and life safety systems generators.

Maintained and repaired boilers, chillers, air handlers, DIW, IWW, scrubbers and closed-loop systems.

Ran chemical tests on systems and adjusted chemical balances as needed.

Cleared clogged drains and replaced defective parts such as valves, faucets and fixtures.

August 2010 to Current

KA Construction Englewood, OH

Estimator / Job Superintendent

<strong strong>Interpreted drawing markups and implemented drawing revisions provided by engineers.

Prepared specifications of electrical systems and topographical maps to ensure that installation and operations conformed to standards and customer requirements.

Coordinated manufacturing, construction, installation and maintenance projects for engineering team to complete per customer requirements.

Coordinated utility service providers according to project schedules.

Obtained building and specialty permits from local jurisdictional agencies.

Performed regular job site observations to provide direction for all general contractor personnel.

Conducted all critical pre-installation conferences with general contractors, subcontractors, consultants and manufacturer's representatives.

Worked with construction administration consultants to plan field observations on schedule.

Prepared and followed through on all required punch lists.

Assisted the operations group with warranty service repairs.

Conducted routine quality audits to ensure that work was progressing per the specifications and initiated corrective actions.

Avoided construction delays by efficiently following through with all site inspections in a timely manner.

Education

Charter University

Bachelor of Science in Engineering 1996

Focusing on Healthcare Construction, Maintenance and life safety

MCJVS and MVCTC Clayton, OH

Certificates received in Plant Safety Operations, Predictive and Preventive Maintenance, building operations. Also received certificate in Maintenance Management systems Fire school, Motor control and more.

Also received Certificates in Electrical AC and DC, Plumbing, Motor control including Allen Bradley and more. York Equipment Training (chillers) 400 Hours Chiller Programming and trouble shooting. 800 Hours in Heavy Equipment Operations. Allen Bradley PLC, Fire School



Contact this candidate