Post Job Free

Resume

Sign in

Electrical Engineer Supervisor

Location:
Dharmapuri, Tamil Nadu, India
Salary:
35000
Posted:
May 16, 2022

Contact this candidate

Resume:

CURRICULUM VITAE

VASANTHAKUMAR.B

BE, Electrical and Electronic Engineering

Email Id: adq22n@r.postjobfree.com

Mobile No: +91-999*******

OBJECTIVE:

To build a progressive career in a challenging environment with best utilization of my technical skills in a growth oriented environment and to present myself with best of my innovative ideas and technical skills.

CURRENT PROFESSIONAL EXPERIENCE: 1

Organization : INEL Power System Engineers Pvt Ltd. Designation : Senior Electrical Engineer.

Period : April 2010 to July 2021.

1. O & M Job Profile:

Project - 220/400 KV Switchyard O & M in kaiga Atomic Power Station at NPCIL, Kaiga

(Karnataka).

• Operation & Maintenance of Transformers 500MVA and Bus reactor (63 MVAR).

• Operation & Maintenance of 765KV & 220/400KV Breakers, Isolators & Earth Switch

• Operation & Maintenance of 220 & 48V Battery Maintenance (300Ah). Job Responsibilities:

• Project implementation, testing & commissioning, supervision of maintenance of Switch yard equipments and Control Panel Trouble shooting.

• Monitoring of Safety Precautions during operation & Maintenance.

• Condition monitoring and preventive maintenance to be carried for switch yard equipments as per the schedule.

• Supervision of maintenance Technicians and Process Operators. Major Job’s attended:

• DI unit, pole and Nitrogen accumulator replaced in 400KV CB.

• Maintenance work done in Nitrogen accumulator due to failure of NRV and Micro switch and contactor failure attend in CB.

• Problems attend in transformer (OLTC, bucholz relay, CCC). LA erection & commissioning. Problem attended in 220KV CT.

2. Testing & Commissioning Job Profile:

• Scheme checking and interlock checking for switchyard and switchgear control wiring circuits.

• Commissioning of various switchyards and power plants.

• Trouble shooting in Transformer and wirings, Circuit Breaker, CT, PT and switchgear wirings.

• Testing various types of Power Transformers, Auto Transformers & Distribution transformers.

• Special testing of Power Transformer like SFRA, TAN-DELTA and DUE POINT, Power Quality analyzer Measurement.

• Testing and Calibration of Protection Relays of all leading (ABB, SIEMENS, AREVA, ALSTOM Easun Reyrolle, L&T, Schneider Electric etc.,) Numerical Relays.

• Testing of all switchyard and switchgear equipments (Transformers, CB, CT, PT, Isolator, CVT, IVT, LA Meters and Transducers).

Project Individually Handled and Commissioned as a Team Leader

• 765KV PGCIL Substation in Jabalpur, MP

• 400/220KV KPTCL Substation in Nelamangala, Bangalore, Karnataka.

• 66/11kV KPTCL Gas Insulated Substation in Bangalore, Karnataka.

• 220/132KV MSETCL Substation in Magarpatta, Pune.

• 132KV/33KV CSPTCL Substation in Kondegaon, Chhattisgarh.

• 110KV/11KV DCBL SubStation Mudhol, Belgaum.

Preventive Maintenance Testing

• Testing of Generator & Line protective relays in M/S. Graphite India ltd at Mysore, Karnataka.

• Testing of P442 Distance relay in M/S. Bangalore Water Supply and Sewerage Board, Harohalli, Karnataka.

• Testing of Protective relays and Meters in M/S. Bhavani Khandsari Sugars Ltd at Bidar, Ka.

• Testing of Protective relays and Meters in M/S. Shri Saikurpa Sugars Ltd at Srigonda, Madhya Prades

• 110KV/11KV Testing of Protective relays M/S. Mysore Paper Mill, Bhadravati. PROFESSIONAL EXPERIENCE: 2

Organization : LARSEN & TOUBRO LTD ECC DIVISION.

Designation : Asst. Electrician.

Period : Jun 2008 to April 2010.

Job Responsibilities:

• Operation and maintenance of Hot Mix Plant and Control panels.

• Operation and maintenance DG, Crasher plant convers system maintenance work carried out.

• Responsible for maintain the all system parameters value within the set points values

• Monitoring of Safety Precautions during operation & Maintenance PROFESSIONAL EXPERIENCE: 3

Organization : TamilNadu Electricity Board.

Designation : Apprenticeship Training.

Period : April 2007 to April 2008.

Job Responsibilities:

• Operation and maintenance of 110 KV/11 KV Sub-Station 20000 KVA Power Transformer-2 nos.

• Distribution Transformers Erection and Maintenance.

• HT / LT Line & Distribution Network, Maintenance work and Line extension & Improvement work preparing of Estimate related to O&M section

• Operation and maintenance of GC Breaker LV & Feeder Breakers.

• Operation and maintenance of 110/11KV protection relays and control panel

• Project implementation, pre-commissioning & commissioning, supervision of maintenance.

• And other equipment’s connected in our switchyard like CT, PT, Las, Motorized Isolators and Battery with battery charger at 110/11KV Sub-station.

• Responsible for maintain the all system parameters value within the set points values

• Monitoring of Safety Precautions during operation & Maintenance. ACADEMIC CHRONICLE:

• Diploma in Electrical & Electronics Engineering – CGPA 71.75% First Class

(Lakshminarayana Polytechnic College – Bagalahalli, Dharmapuri - 636807, Tamilnadu. India)

(Approved by AICTE, New Delhi & Government of Tamilnadu)

• BE, Electrical and Electronic Engineering – CGPA 7.91% First Class

(J.K.K.Nattraja College of Engineering and Technology – Kumarapalayam, Namakkal Dt, TN. India)

(Approved by AICTE and affiliated to Anna University Chennai) ELECTRICAL SUPERVISOR PERMIT GRADE 1:

Electrical Supervisor Permit No: 1SP155859BNG

SKILL SET:

Office Package : Ms-Office

Web Design & Technology : HTML, Front Page, Adobe Photoshop CS, Auto CAD PERSONAL PROFILE:

Father’s Name : Boopal.B.

Date of birth : 01/06/1985.

Gender : Male.

Marital Status : Single.

Nationality : Indian.

Language Knows : English, Tamil (Kannada, Hindi, and Telugu only to Speak) Notice Period : 15 days

Present Address : Dr. Raj Kumar road, Raj Arcade, Rajaji nagar, 6 th

block,

Bangalore, pin: 560010.

Permanent Address : No: 1, M Raji road, Golden Street, Dharmapuri, Tamilnadu – 636701

DECLARATION:

I hereby declare that above mentioned information is correct up to my knowledge and I bear the Responsibility for the correctness above mentioned particulars. Place :

Date : Vasanthakumar.B



Contact this candidate