CURRICULUM VITAE
Name: - Samuel Vijayan
Mobile No.:- 900-***-****
Email id: - *********@*****.***
Post Applied For: ELECTRICAL TECHNICIAN
Objective:
To work in a healthy, innovative and challenging environment extracting the best out of me, which is
conducive to learn and grow at professional as well as personal level thereby directing my future
endeavors as an asset to the organization.
TECHNICAL QUALIFICATION
Diploma In Electrical & Electronics Engineering @ Hi – Tech Polytechnic College in Tamilnadu
With 66% First Class Pass at the period of 25th July 2014.
WORK EXPERIENCE: 5 Years’ Experience as “Electrical Technician” In India at Electrical Maintenance.
Employment Details:
1. Power Audit Engineer At Choice Solutions Ltd – Mumbai
Site : Client Location
Location : Pan India
Duration : 19th February 2018 to Till Date
Job Profile : Power Audit Engineer
• Power Quality analysis using Fluke 3 phase power analyzer.
• Thermography using Infrared thermal camera
• Light intensity measurement using Lux meter
• Earth Pit test using digital earth tester.
• Generation of Audit report using computer software
2. Electrical – Operation & ISS facility service Under the contract of Reliance Corporate IT Park,
Navi Mumbai.
Site : Reliance Corporate IT Park
Location : Ghansoli, Navi Mumbai.
Duration : Jan 2015 to Jan 2018
Job Profile : Maintenance Engineer
• Preventive & Breakdown maintenance
• Operation & Maintenance of 11KV/433V 2.5MVA & 2MVA Transformers.
• Knowledge of Transformers & Distribution Systems.
• Knowledge of Siemens and L&T makes Switchgears Control Circuits & Wiring Drawings.
• Installation, repairing & testing of HV, LV electrical equipment’ s, this includes motors,
breakers, MCC Generator & Battery.
• Installation of cable laying, jointing, glanding & Termination.
• Maintenance of AC & DC Motors up to 100HP.
• Gulf:power Audi t engineer at gulf genuine power co llcInstallation & Troubleshooting of UPS
up to 60KVA.
• Functional Test, megger, continuity test & physical checks as per the test format.
• Isolations & De-isolations as per the work permit with proper tags & locks.
• Trouble shooting, fault finding & rectification of all types’ panels (DOL, S/D, ATS, ACB, VFD,
Relay & Metering panels.
• Complies with safety conditions & practice on all equipment’ s on which he is working &
observers the work permit regulations.
• Knowledge of motor overhauling like dismantling bearing removal & testing replacing,
inspection windings & assembling.
• Follow test procedure for relay testing like over load relay, testing like over load relay earth fault
relay, under voltage relay, and prepare test reports.
WORK EXPERIENCE: 2 Years’ Experience as “Power audit engineer” In Oman .
Power Audit Engineer At Gulf Genuine Power co llc-Gulf.
Site : Client Location
Location : Pan oman
Duration : 17 Dec 2019 to Till Date
Job Profile : Power Audit Engineer
•Preventive and breakdown maintenance for 33kv, 11kv, lvac panel with motors
•B2 hipot test system used for 33kv, 11kv cable testing operation.
•Transformer test system using transformer.
•Zera energy meter booter used for energy meter calibration work.
DAILY OPERATING PARAMETERS READING
• Turbine Generator Control Panel Reading.
• U.P.S. Systems, Reading.
• Booster Compressor Reading.
• HVAC Chiller Unit & Air Handling Unit Readings.
MAINTENANCE OF MOTOR
• When on electric motor has been properly installed it requires little attention later on to keep it
working properly. If the motor is kept clean & dry and properly lubricated it will give trouble free
service for a long time
The following are the maintenance works to be carried out in a Motor.
• Check all high speed bearings & renew if necessary.
• Blow out all motor windings thoroughly with clean dry air.
• Overhaul motors which have been subjected to severe operating conditions.
• Check insulations resistance to earth between phases of motor windings, control gear & wiring.
• Clean and Vanish dirty and oily Windings.
• Renew Switch and Fuse Contacts if necessary.
• Check the resistance of earth connections.
• Check the air gap and ensure that the rotor does not rub against the stator core.
• Renew oil in starters subjected to damp or corrosive elements.
• Ensure that the ball or roller bearings have adequate lubricating grease.
POWER GENERATION OF THE PLANT
Three Different Power Generation Systems have been fore seen.
• Normal Power Generation by Turbo gas Generators.
• Emergency Power generation Diesel Generators.
• Safety Power source represented by Accumulator Batteries.
PLATFORM LIGHTING MAINTENACE
• Plat form lighting. Helideck lights & Navigation Aids lights, Safety lighting System & Junction
boxes.
3. Project – II: Raymond’ s Hr. Sec School, Thane.
• Wiring.
• LDB & SDB Installation.
4. Diploma Apprentice
• Electrical – Operation & Maintenance at LMW LTD, Coimbatore - India.
From June 2014 to January 2015.
PERSONAL SAFETY PROTECTIVE EQUIPMENT (PPE) RULES
Cotton overall / Dungaree, Safety Shoes, Hand Gloves, Safety Goggles Ear Muffs / Plugs, Life
Jackets / Work Vests / Safety Belts / Harness, Self Contained Breathing Apparatus (SCBA).
Other Computer Proficiency:
• MKCL, MS – CIT,
• Ms-office, Ms-word, Ms-Excel, Ms-power point.
Personal Strengths:
• Ability to work in a team
• Thirst towards learning
• Inherent Perseverance
Personal Information:
D.O.B : 26th April 1993
FATHER NAME : Vijayan
GENDER : Male
MARITAL STATUS : Married
BLOOD GROUP : A+
NATIONALITY : Indian
LANGUAGES KNOW : English, Hindi, Marathi & Tamil
PERMANENT ADDRESS : 4/736 Duraiswamy enclave, Mathvarayapuram post,coimbatore-
641101.
EDUCATION QLF : SSLC
TECHNICAL QLF. : Diploma in Electrical & Electronic Engineering
Passport Details
Passport Number : T6626853
Place Of Issue : Mumbai
Date Of Issue : 24th June 2019
Date Of Expiry : 23rd June 2029
DECLARATION
I hereby declare that the above written particulars are true and correct to the best of my
knowledge and belief.
Date:
Place:Coimbatore (Samuel
Vijayan)