Professional Synopsis

Contributor Profile

Experience From OCT 2015 TO JAN 2021

Mobile: +91-701*******

E-mail:dipuparichha3 @gmail.com

A good professional with 5.8 Years of experience in Maintenance, commissioning Field plants like oil & gas Refinery, petrochemical substation .

I have knowledge of planning software like Primevera P6,drafting software like autocad 2d, Etap use for sld and fault relay coordination and intellectual presentation.

Knowledge of reliability methodologies and strategies such as RCM, TPM, Planning & Scheduling .

Expertise in supervision and execution & Quality control in Construction, Testing & Commissioning and Maintenance of the projects.also work in electrical and instrument field.

Experience in various international codes /standards use viz.ASME,API,ASTM,IEC,IEEE,NEMA,ANSI .

Recent Experience

Here I am working as E&I QA/QC eng through PCTS at ongc Mumbai offshore. Here I worked in un maned platform.

JOB RESPOSIBILITY:

• Verify & checklist preparation of Installation of instrument by following P&ID.

• Calibration of instrument and check MRIR report making,instrument data sheet follow.

• Line charge or keep FT,LT,PSHL,PT,TT in line service.

• Prepaaration of Hydro test,pneumatic supply to verify strength of tube joint and connection pressure applied are refer to P&ID sheet.

• Hot loop check through HART 475 also simulation and screen change.

• Check HMI graph and rtu connection during hot loop perform.

• F&G panel,Solar panel,Batery Bank,RTU,TIC Panel commissioning.

Here I am working as an Electrical Eng at MAEDA CORPORATION INDIA PVT. LTD at Sricity,Andhra pradesh .

JOB RESPOSIBILITY:

• Work on drawings making through auto cad & execute site activity,plant .

• Follow up client requirement and BOQ,arrange resources and manpower to activity. SIMANCHALA PARICHHA E&I Engineer

• Involve in substation design cable laying,transformer erection,testing and commissioning.

• APFCR panel commissioning.

Previously I had working as an Electrical Eng under TECNIMONT PVT Limited, Jamnagar in Ril HIIR unit.( Continue From FEB 2019 TO AUG 2019).

JOB RESPOSIBILITY:

• Responsible for complete check process variable installation,testing,commissioning .

• Plant Earthing and lightening protection system,condouct material receiving inspection,junction boxes,instrument local panel,cable laying inspection checklist preparation as per ITP.

I had work as an E&I Engineer (project) in accurate logistic Agency of l&T HYDROCARBON(2017FEB to 2018 dec).

JOB RESPOSIBILITY:.

• Flawless commissioning & plant startup activities of SEZ-PCG & DTA-PCG plant

• Good knowledge of SLD, electrical drawing and also work permits and electrical lock out and tag out systems.

● Work in vendor document review and step wise test Factory acceptance test,site review of sat.

● Cable laying,gland termination done.

● Reconcilation sheet preparation of cable,jb,steel,gland,light,project prodouct .

I had work as an Electrical project supervisior in “substation of 66kv/33kv(33kv/6.6 kv)C2 COMPLEX,TANK FARM AREA (KONSTELEC ENG PVT LTD), jamnager from feb 2016 to jan 2017.

JOB RESPOSIBILITY:

• Knowledge of operation and maintenance of LV/MV/HV electrical system like11KV substation, 415 rated PCC 3500Amp, MCC 800Amp, PMCC 1600Amp, hvac.

• In this company I work as a testing eng and perform magnetic current,magnetic balance,vector group,wr,ir,sc&op ckt,ct(kneepoint,polarity check),cable hipot,protection alaram check.

• Installation&testing of Power transformers, C.T. & P.T., circuit breakers.

• Testing & commissioning of HT & LT motors feeder with control & No-load trial & Load trial of motors during precommissioning period of plant.

I had work as an Electrical&Instrument QA&QC engineer (project) in TECHNIMONT ICB from SEP 2015 to FEB 2016.

JOB RESPOSIBILITY:

• Execution work as per Cable schedule, Cable tray Layouts, Earthing Layouts, Lighting Layout, Single line Diagram, Electrical equipment layout as per drawing&execute. Detail Personal

Declaration

Examination/ Degree Board/University Passing Year

Percentage/

CGPA

DIPLOMA ( electrical) SCET&VT 2015 73

S.S.C ODISHA HSE 2011 65

COMPUTER SKILLS:

Auto cad 2d&3d completion in 2015,basic knowledge of sap pm, Etap. Full name Simanchal Parichha

Address

home/permanent

(Plot no h 3066/9)Prakat residency,Golden square,Ankleswar Gidc,Gujrat.pincode-393002

Date of birth 11

th

July 1995

Gender Male

Language known English, Hindi,Odia

Marital status Single

Nationality Indian

Passport No. S9032126

Hereby I enclose a copy of my resume for your kind reference and declare that the above given information is true to the best of my knowledge and I will perform the best in my skills. SIMANCHAL PARICHHA