**** ******** **. **********, ** *****
714-***-**** / *******@*****.***
OBJECTIVE
A position as related to my experience in the field.
SUMMARY OF QUALIFICATIONS
Clinical Chemist Scientist I with a total of 8 years of work experience in the laboratory.
Excellent Chemical Analysis and Quality Control experience.
Strong Pharmaceutical Background.
Dedicated and efficient; proactive and motivated; willing to assume responsibilities.
EXPERIENCE
Labcorp, Burlington, NC 27215 2021- Present
Sr. Technologist
Hematology Department
- Perform Body Fluid Assay ( Synovial and serous fluid).
- Follow the laboratory’s procedures for specimen handling and processing, test analyses, reporting
and maintain records
- Adhere to the laboratory‘s quality control policies and maintenance performed.
CONTRACTOR
Renovation and UpGrade old houses 2018-present
Quest Diagnostics at Nichols Institute, San Juan Capistrano, CA
CLINICAL CHEMIST SCIENTIST 2009– 2018
Automated Chemistry Department
*Utilized the following instruments:
-Nova 8 Analyzer (ISE- Ion Selective Electrode) to quantitate Ionized Calcium.
-Beckman Coulter AU2700 (Colorimetry) to analyze BHBA (beta-Hydroxybutyric Acid), NEFA (Non-esterified Fatty Acid), ACE (Angiotensin Converting Enzyme), Oxalate & Citrate, Micro Total Protein and Urine Chemistries (Magnesium, Calcium, Phosphorus, Uric Acid and Creatinine)
-Beckman Coulter AU680 and Hitachi 940 to analyze Glycomark, Fructosamine and Microalbumin
-Beckman Coulter AU640 to analyze G6PD and Cholinesterase
-Roche COBAS Integra 800 to review the test runs and report on the following analytes: RF, C3, C4, IgG, IgA, IgM, CRP, ASO, IgAP, IgMP and HbA1C.
*Ran CAP Surveys. Performed Linearity on instruments, as well as Reagent & Instrument Correlations.
LABORATORY ASSOCIATE 2009 – 2009
Hematology Department
*Primarily worked and assisted the CLS in the Flow Cytometry Core Facility.
Huntsman Advanced Material, Los Angeles, CA 2003 – 2009
QUALITY CONTROL ANALYST
*Inspected and tested samples submitted to QC for conformance to specified requirements accurately, efficiently with proper prioritization. Samples included raw materials, intermediates & finished goods.
*Took lead and coordinated with QC Lab activities (Personal and Inventory) and with other company departments (Manufacturing, Planning, Purchasing, Packaging, etc.)
*Maintained all required Quality Records, including data entry into QC Card and SAP.
*Coordinated with manufacturers for dumping, releasing and adjusting sample under all conditions.
*Maintained and kept laboratory equipments and supplies in good working condition.
B. Braun Medical Inc., Irvine, CA 2000 – 2003
QUALITY CONTROL ANALYST
*Monitored weighing, mixing and made changes needed to make daily goal.
*Performed routine chemical tests on raw materials, in-process and finished products, environmental and stability samples according to established specifications and procedures.
*Operated a variety of instruments: Polarimeter, Flame Photometer and Chromatographic equipments
Page two
Alpha Therapeutic Corporation, Los Angeles, CA 2000
QUALITY CONTROL ANALYST
*Performed water analysis for injector (Conductivity, Oxidizable substance, Silica, pH)
*Performed Kjeldahl Nitrogen system using Buchi equipment.
*Carried out protein analysis in AHF and A1-P1 by using Spectrophotometer method.
*Performed Coagulation Factor IX (FIX), Elution factors and Factor VIII using Activated PTT method.
*Performed test of Bacterial Endotoxin, Limulus Amebosyte Lysate by Gel Clot Method.
John Wayne Cancer Institute, Santa Monica, CA 1999 – 2000
QUALITY CONTROL ANALYST
*Conducted QC analysis on raw materials, intermediates and final products.
*Performed culture cells in an aseptic environment. Followed cGMP and GLP practices.
*Analyzed results and wrote reports for the following assays: LAL, ELISA and rhGM-CSF.
Baxter Healthcare Corporation, Hyland Division, Los Angeles, CA 1997 – 1998
QUALITY CONTROL ANALYST
*Used Gas Chromatography and Flame Photometer; Biuret & Ultraviolet methods to test Total Protein.
*Performed VIII and IX (Anti-Hemophilia) assay via Coag-A-Mate.
*Tested Autoplex samples using Micro Centrifugal Analyzer. Done routine tests in Plasma & Albumin.
*Entered data results into a LIMS database system.
V.O.C. Analytical, Glendale, CA 1996 – 1997
ANALYST
*Performed extraction techniques of water, soil and oil matrix using the following methods: (L-L) continuous, Soxhlets, Dilution, Separatory funnels, EPA Methods; 8270/8310/8080/8040/8150.
Pacific Toxicology Laboratory, Los Angeles, CA 1995 – 1996
ANALYST
*Prepared samples for analysis of Arsenic and Mercury in urine.
*Performed analysis using Hg Monitor.
Alexandria Pharmaceutical and Chemical Industries Research Control, Egypt 1991 – 1993
CHEMIST
*Carried out raw material testing for in-process products using UV, IR and wet chemistry analysis.
*Performed routine and non-routine chemical analysis of water using a variety of classical techniques (pH, Conductivity, water content, titration, checking for Calcium, Sodium, Carbon, etc.)
ADDITIONAL SKILLS
Also adept in the following instrumentations:
HPLC: HP and Water Systems Gas Chromatography: Varian, 3600
Wet Chemistry: DMS Titrino, 716 Turbidimeter, Hach Ratio/xr Hamilton Diluter Microlab 500 Series Automatic Flame Photometer, II 943
Density Meter D.M.A. 45 Fluorescence Light Scattering Multistat III. UV/VIS: Beckman Spectrophotometer, Model DU-640
IR: Perkin Elmer Model 1600
EDUCATION AND TRAINING
Clinical Chemist Scientist License Number: MTC745, State of California License
B. S. in Chemistry, Alexandria University, Egypt, 1991
Project: Basic thermodynamic analysis of solution by utilizing the electrical and optical proportion of the solution.