V.JAGDISH

INSTRUMENTATION LEAD

Oil & Gas Offshore & Onshore Instrumentation & Control Retrofits Design E&I Commissioning Wellhead Control Panels DCS Operations & Maintenance Gas Turbine Generators/Compressor Drives Reciprocating Gas Engine/Compressors Custody Transfer Metering Analyzers

AMBITION

To honestly and dedicatedly serve my organization where my passion for Instrumentation & Control can be implemented for the success of the organization as well as my career.

CORE QUALITIES

• Loyalty, Integrity and dedication to my company and those I serve.

• Perseverance to maintain International safety standards.

• E&I experience at onshore and offshore platforms.

• Operations & Maintenance of Cryogenic Process Plant and Turbine systems.

• Excellent Communication and Interpersonal Skills, team player.

• Able DCS Panel Supervisor.

EXPOSURE TO THE FOLLOWING SYSTEMS

• Plant maintenance CMMS software; AMOS, AMAS.

• DCS: Emerson Delta V, Honeywell TDC 2000.

• SOLAR TURBINES USA: 12 years’ experience on Saturn.

• WAUKESHA Gas Engines for Reciprocating Compressor: Ingersoll Rand, AJAX.

• Rockwell Automation HMI, Allen Bradley RS LOGIX 5000 PLC.

• Major Overhaul of GE Frame V Gas Engones for 25Mw Generators.

• Instrumentation: Multivariable Transmitters, Control & Shutdown Valves, Foundation Fieldbus.

• Custody transfer metering, USFM Gas Flow Metering, Brooks Veeder Root PD Meters

TRAINING COURSES ATTENDED

• ROCKWELL AUTOMATION- Allen Bradley PLC5/15 Configuration & Logic Design, Programming & Diagnostics, DH+ network; Duration: 12 days.

RSLOGIX5000, CONTROL LOGIX, CONTROLNET, DEVICENET.

• MCSE (Microsoft Certified Systems Engineer) Networking.

Cambridge Institute, Dubai.

• Apprenticeship Training at MICo BOSCH-Bangalore - 3 Years;

• Engineering Drawing, Materials & Processes, Instrumentation, Electrical, Electronics,

Pneumatics and Hydraulics.

• Process Control Instrumentation

• All forms of Machine work; Milling, Turning, Grinding, Planing, Slotting.

• In-plant training; Machine shop, Surface treatment, Hardening shop, Design dept., QAQC, Instrument Dept.

• SAFETY; OPITO-TBOSIET, COXWAIN, Advanced firefighting, PTW, Advanced Risk Assessment, Supervisory Safety Management.

• MOORE MICRO PSC2000 for Gas Turbine Control System SPEEDTRONICS Retrofit Design of G.E. Fr.5, with John Brown Engineering at ALBA-(Aluminium Bahrain)

• ISA CIAT (Certified Instrumentation and Automation Technologist), Pune, India.

• INTOOLS, SMART PLANT INSTRUMENTATION/ AUTOCAD

• CMMS for Plant Maintenance; AMAS, AMOS

PROFESSIONAL EXPERIENCE

Lead Instrument Engineer (Nigeria EBOK Offshore) July 2018 to Jan 2021

OCS Nortrans

Maintenance, spares management and training of Nationals at Mobile offshore Production Unit (MOPU); Process Unit Instrumentation, Compressors, DCS, Wellhead control systems, Power generation systems, Fire-Safety-Security systems and Auxiliary package units.

Lead Instrumentation Engineer (Nigeria, EBOK Offshore) Nov.2017 to May 2018

Asian Oil Field & Energy Services

Maintenance, spares management and training of Nationals at Mobile offshore Production Unit (MOPU); Process Unit Instrumentation, Compressors, DCS, Wellhead control systems, Power generation systems, Fire- Safety-Security systems and Auxiliary package units.

Supervisor-Instrumentation & Control Nov.2014 to Nov.2017

Vishal Petrotek Industries,

Bangalore, India

Instrumentation & Control Consultancy, Design, Commissioning and support services.

Instrument Dept. Supervisor-Head of Dept. (U.A.E Offshore) Aug.2013 to Aug.2014

R.A.K. Gas Commission, Ras Al Khaimah, UAE

• Maintenance / spares management, support services for Offshore Satellite Platforms & Onshore Gas plant consisting;

• Wellhead control panels, test separators

• Cryogenic LPG plant, Oil & Gas plant, associated metering, loading station.

• SOLAR Turbine Booster Gas Turbine compressors.

• Custody Transfer Gas Flow Metering Telemetry stations.

Lead Instrument Engineer (Nigeria EBOK Offshore) July 2010 to June. 2013

Mercator Offshore Nigeria Ltd.

• Gulf Copper dock yard, Galveston, Houston, Texas, U.S.A:

Installation & commissioning of Instrumentation, SOLAR TURBINES generator set & Delta V DCS.

• EBOK Nigeria MOPU/FSO:

Maintenance and spares management of Process unit, Wellhead systems, GT Power generation, fire & safety.

C.C.R, D.C.S panel Supervisor (Nigeria Port Harcourt Onshore) June 2008 to Oct.2009

NAOC-Nigerian AGIP Oil Co., ENI Group

Nigeria

DCS Migration from Yokogawa RS3 to Emerson Delta V, Commissioning & Tuning of Gas/NGL GT compressors and process plant.

C.A.E. (Control & Applications Emirates) Abu Dhabi, U.A.E. June 2006 to Mar.2008

Site Manager/Project Engineer

• Site Manager at TAKREER BeAAT site- S.N.C. Lavalin project.

• Project Engineering; Studying Tenders and Preparing Techno-Commercial submittals.

Accomplishment:

• As site Manager at Jan Yafour field development project, early detection of missing cable entry slots in CCR/MCC civil works for MCC panel and arranging alternatives, prevented project delay

• Project Engineer: Studied enquiries, review of tenders, preparation of Techno-Commercial submittals and follow-up meetings.

I/E Supervisor (OFFSHORE & ONSHORE) Nov 1993 to Dec 2005

Head of Instrumentation & Electrical Dept.

R.A.K. Gas Commission, Ras Al Khaimah, UAE

• Maintenance and spares management of 7 Offshore Satellite Unmanned Wellhead Platforms, onshore systems for Process Control and Gas Turbines Control systems.

• Root Cause of every shutdown was analyzed rectified and modified, thus minimizing down time.

Sales & Service Engineer- Instrumentation

Nov. 1992-Aug 1993

M.M.I. Instrumentation Department, UAE

• Managed erection, commissioning of Instrumentation for Test Separator at Jan Yafour Field Dev. Project - Abu Dhabi gathering center.

• Calibration, certification, sales & service of Instrumentation & Gas Monitors.

Control & Instrumentation-Tech. Engineer (Power Maintenance) April 1991-Nov 1992

Aluminium Bahrain (ALBA)

• Assisted John Brown Eng. Retrofit of Speedtronics modular controls for GE Frame5 Gas Turbine Control system to MOORE PSC PC based system.

• Maintenance of Combined Cycle Power Plant, major overhauls of 19 GE FRAME 5 Gas Turbines and Speedtronics calibration.

Sr. Instrumentation Foreman (Rotary Equipment) CMMS Project

IMCO., Kuwait Oil Company, Kuwait.

Developed CMMS system for Aero-Derivative Gas Turbine Control systems of GE, Rolls-Royce Avon with Entronic control Systems, SOLAR Turbines and Bentley Nevada systems.

May 1989-Aug 1990

Instrument Foreman

M.F.Kent/Kellog Plant Services

Instrumentation service at workshop, Analyzers, Foxboro DCS Maintenance of CDU, HP, ARD, HSR/SRU Plant and Analyzers.

Instrumentation Foreman

Madras Aluminium Co.,(MALCO)

• Managed a team of nine technicians, maintenance & spares management of Instrumentation for Boilers, Evaporators, Oil Fired heaters, Pot room, furnaces, extrusion plant and Lab.

Aug 1986-Mar 1989

March 1984-June1986

Jun 1986

EDUCATION

N.C.T.V.T. Instrumentation at MICO-BOSCH, Bangalore, India. 1980 to 1983

National Vocational Training, First Class

3 years course by Government of India.

Diploma in Electronics: First Class 1981 to 1983

DATAMATICS Corporation, Bangalore, India

M C S E: Windows NT Course from Cambridge Computers- Dubai.

ISA-CIAT (Certified Instrumentation & Automation Technologist)

DTECH-01: Introduction to PC and DOS

University of Kuwait, Al Khwarizmi Program.

MEMBERSHIP

I.S.A (The Instrumentation Systems, and Automation Society - U.S.A)

IETE- Institution of Electronics & Telecommunication Eng. Student member

LANGUAGES

Fluent in English and most Indian languages, can read and write Arabic.

HOBBIES

Aviation, Instrumentation, Electronics Technology updates.

SPORTS

• Yoga.

• Represented High School and MICO-BOSCH in Hockey, Football teams.

• Private Pilot License of U.A.E.

• N.C.C. (National Cadet Core) Bangalore.

REFERENCES

1.Mr. Mike Oriaku-CAR, OERL, Nigeria +234********** (Present Client at EBOK Offshore)

2.Mr. James Esoa; Operations Engineer, OCS, MOPU, EBOK, Nigeria. +234 805-***-****

3.Mr. Godwin; Nigerian Agip Oil Co. (NAOC)OBOB, Port Harcourt, Nigeria. +234 803-***-****

4.Mr.Krekoir Kasimjian; Ras Al Khaimah Gas Commission, United Arab Emirates.+971*-*********

PROJECTS DESIGNED AND EXECUTED BY ME AT RAS AL KHAIMAH GAS COMMISSION INHOUSE

IMPROVING AVAILABILITY AND RELIABILITY

During my 12 years of service as Head of the Instrumentation & Electrical Department, some of the main projects designed and implemented by me are as follows;

1. Emergency Power System

The emergency generator and MCC consisting of Klockner Moeller Motor Operated Circuit breakers controlled by Allen Bradley PLC2, retrofit designed and implemented successfully.

2. Reboiler Heater H102 & Hot Oil Heater HT1401

Temperature control and shutdown system was upgraded from pneumatic to digital Honeywell UDC 3000.

The Burner Management system was upgraded to safer efficient logic. UV detectors, upgraded to Honeywell units improving the efficiency, reliability and reducing warehouse inventory.

3. Honeywell DialTrol Temperature switches

These units operating on 110VAC were modified in-house to operate on 24 VDC UPS.

Hence unaffected by plant power dips, rendering 3 Inverters obsolete.

4. SOLAR Gas Turbines Ignition Logic

A. The ignition detection logic was transferred from T7 (Exhaust temperature) sensing to T5 (Wheel space) sensing with redundant contacts.

Thus, improving Ignition system efficiency, reliability and safety.

B. Surge Shutdown system, frequent shutdowns analyzed, suggested solution to SOLAR TURBINES and implemented. Preventing recurrence and production loss.

5. LPG Tanker Loading Flow Computer

This Daniel flow computer, operating on 220VAC, computed and controlled the LPG loading operation which was frequently disrupted by power failures.

The unit was modified to 24VDC UPS, ensuring uninterrupted operation.

6. Elevated Flare System

Frequent rupture pin actuation during Preventive Maintenance; root cause was analyzed to pipe line internal explosion, advised to Operations and prevented recurrence by modified operational procedures.

7. Gas Metering Stations at Consumer skids

Initiated the idea to monitor remote gas metering Daniel Gas Flow Computers by leased line communications to Main Control Room. Implemented and reduced operational man-hours and obtained live field data.

8. SCADA

Initiated the idea to implement the LPG Sweetener controls the SCADA, thereby improving operations and safety.

10. Training

Conducted Instrumentation training for Operation & Maintenance personnel.

V.Jagdish