Post Job Free

Resume

Sign in

Power Plant Electrical Engineer

Location:
Santa Maria, Batangas, Philippines
Posted:
April 05, 2021

Contact this candidate

Resume:

+639*********

adlfwb@r.postjobfree.com

*** ****** **. ***. *****,

Bauan, Batangas, Philippines

EDUCATION

BS in Electrical Engineering

Batangas State University

Alangilan, Batangas City, PH

2010 – 2015

PROFESSIONAL SKILLS

BENJOE S. HERRERA, REE, RME

SUMMARY

Electrical Engineer with more than five (5) years of wide experience and expertise on High/Medium Voltage/Low Voltage (HV/MV/LV) electrical system and equipment in different industry such us: Geothermal Power Plant, Coal Power Plant, Waste Water Treatment Plant, Diesel Power Plant, Gas Plant, Manufacturing industry

(FMCG companies), Mining and Cement industry, Building construction. Can provide technical expertise for MV/LV electrical system in any categories like installation, retrofitting, testing & commissioning, repair and troubleshooting, operation maintenance, and engineering design/consultancy. FIELD SERVICE ENGINEER, - March 2018 to present

BGC Taguig City Philppines, SCHNEIDER ELECTRIC is a European multinational corporation that specializes in energy management, electrical equipment, automation solutions, spanning hardware, software, and services. CONTROL ROOM ENGINEER / POWER PLANT OPERATOR, - July 2016 to January 2018 Aboitiz Power Corporation (Aseagas Corporation on Lian, Batangas) an 8.8 MW Biomass Power Plant/CO2 Plant renewable energy plant that has a capacity of 8.8 MW and a 33 tons per day liquid carbon dioxide (LCO2) SITE ENGINEER / QA-QC ENGINEER, - October 2015 to July 2016 Sta. Ana Builders Inc. (Makati City, Philippines) an electrical contractor on high rise horizontal building construction and land development project. SKILLS AND QUALIFICATION

Under Service department of Schneider Electric

Professional on doing installation, retrofitting, maintenance, troubleshooting, testing and commissioning of 460V - 36KV type tested MV/LV Switchgear, up to 24KV Ring Main Unit (RMU) and 460V – 36KV MV/LV circuit breaker.

Programming, troubleshooting, testing and commissioning of protection relay SEPAM series 80, 60, 40, 20, VIP series. In addition, capable of using Omicron CMC 356 testing equipment.

Programming, troubleshooting, testing and commissioning of MV/LV Variable Frequency Drive (VFD) and Soft Starter.

Configuration, testing and commissioning of Power Meter (PM and ION series) and connected to Current Transformer (CT), Potential transformer (PT).

Technical expert on communication devices with communication protocol like modbus RTU and TCPIP, DNP3, IEC 61850 that is linked to IoT.

Testing and commissioning of different kinds of MV transformer.

Can interpret electrical drawings and well versed on electrical system audit

Technical knowledge on Power monitoring expert (PME), gateways and SCADA.

Under Aboitiz Power Corporation, a fully pro-active electrical engineer in the field of power plant operation and maintenance.

Well versed on Anaerobic Digester System, Waste Water Treatment System, Power Generation System, CO2 plant, Gas Upgrading System.

Can provide support on field instrument integrated to, PLC, HMI, SCADA

Hands on knowledge on operation and maintenance of a GE Jenbacher Type 3/Type 4 Gas Engines (General Electric).

Experience in supervision, cost estimation and scheduling works on project engineering and management.

Well-informed in different hazards pertaining to gases and chemicals like H2S that present usually on power plant.

Trained Basic Occupational Safety and Health (BOSH), First Aider, Power Plant Gas/Chemical Hazard Awareness and Fire Fighting and Fire Prevention. TESTING AND COMMISSIONING

• VERY GOOD

OPERATION AND MAINTENANCE

• VERY GOOD

INSTALLATION AND RETROFIT

• VERY GOOD

TROUBLESHOOTING / REPAIR

• VERY GOOD

PLANNING / COST CONTROL

• GOOD

ENGINEERING DESIGN

• GOOD

AUTOCAD

• VERY GOOD

PROJECT MANAGEMENT

• VERY GOOD

MICROSOFT OFFICE

• VERY GOOD

PERSONAL ACHIEVEMENTS

Former quizzers of electrical

engineering department.

Won 3rd place in National

quiz show (Engineering

Sciences and Applied

Subjects) held on November

2014 at SMX Convention

Center, Pasay Manila

managed by IIEE

organization

Passed a licensure exam

Registered Electrical

Engineer, September 2015

Passed, 85.55%

Passed a licensure exam

Registered Master

Electrician, September

2015

ORGANIZATION

Institute of Integrated Electrical

Engineer (IIEE)

TRAINING AND

SEMINAR

Basic Occupational Safety and

Health (BOSH)

World Safety Organization (WSO)

DGA (Dissolved Gas Analysis)

PAMAV Training Center

First Aider

Red Cross Batangas Chapter

ON TO POWER

Schneider Electric

Power Monitoring Expert

Schneider Electric

Technical Safety Training

World Safety Organization (WSO)

Fundamentals of Substation

Equipment Maintenance and

Testing

IIEE Northern Laguna Chapter

Advanced Electrical Safety

IIEE Abu Dhabi chapter

ACCOMPLISHMENT/ MAJOR PROJECT

SCHNEIDER ELECTRIC (PHILS.)

Field Service Engineer (March 2018 – present)

Energy Development

Corporation

(1457.8MW Geothermal

Power Plant)

-Testing and commissioning of (ATV630 - VFD)

LV Variable frequency drive and ongoing

(ATV6000 - VFD) MV variable frequency drive -

with a 3.2M USD contract

Valencia, Negros Oriental -Retrofitting (Installation/testing and commissioning) of 7.2KV MV circuit breaker from

OCB to VCB.

-Testing and commissioning of Sepam 40

protection relay.

RCBMI Cement Plant

Project

Norzagaray, Bulacan

Testing and commissioning of MV switchgear a

7.7KV MCset including Sepam T87 as protection

relay

Nestle Corporation

(Tanuan Batangas)

Testing and commissioning of 36KV MV

switchgear F400 including Sepam 80 as

protection relay

Testing and commissioning of LV switchgear

Blokset

Jobin SQM (subic bay)

30MW Solar Power plant

Subic Zambales

Comprehensive Testing of power stations with

36KV MV switchgear DVCAS RMU including

VIP 300 as protection relay and 2.5MVA

transformer Minera oil

JTI Project (under Toenec)

Lima Batangas

Testing and commissioning of 36KV SM6 MV

switchgear including SEPAm 40 as protection

relay

225MW DIESEL POWER

PLANT 1590 ENERGY

CORP - Bauang La Union

L4 Preventive Maintenance contract on

substation 24KV MV switchgear GEC ALSTOM

with 24KV FP circuit breaker

Bank of the Phils. Inc.

PROJECT – Makati

Full ecofit solution (retrofit) on LV circuit

breakers from masterpact M to masterpact NW

(800A-6300A)

Sem Calaca Power

Corporation

Calaca Batangas

-Maintenance contract on substation 36KV type

tested TOSHIBA MV switchgear and MCC

control panel

-Retrofitting of 30pcs LV circuit breaker Toshiba

to masterpact NW (Schneider Electric 800A-

3200A). 23Million project

ePLDT Vitro PROJECT

Pasig Manila

General Electrical Audit and actual revising of

whole Single Line Diagram.

-Designing / Construction / Testing and

commissioning of 4units of 2.5MVA padmount

transformer. Phase 0 project.

July 2016 – January 2018

Aboitiz Power Corporation (Aseagas Corp.)

Testing and Commissioned of Anaerobic Digestion System. Operated Mesophilic Anaerobic digestion system to produce Biogas by monitoring chemical parameters such as VFA, COD, pH, Temperature, etc.

Commissioned of GE Jenbacher Type 3/ Type 4 Gas Engines. Operated Gas Engines according to the availability of Biogas production.



Contact this candidate