C&I COMMISSIONING MAITEANCE ENGINEER
ABHISHEK K SINGH ****************@*****.***
MIG-43,Deendayalpuram,Phase-1, +91-724******* /807-***-****
TV Tower Road,Raigarh,C.G
CAREER OBJECTIVE :
Highly motivated and goal oriented professional seeking an opportunity to contribute abilities and knowledge for personal as well as professional growth.
SUMMARY OF SKILLS : Total 11 Year Experience in Commissioning, Project & Maintanence .
Commissioning,Repairing &maintenance of C&I Packages in Boiler,STG& DCS.( Valves, instruments, sensors, Analyzers, PLC and DCS systems).
Skilled in planning the preventive and breakdown maintenance schedules .
Proficient in identifying areas of obstruction / defects and conducting service and repair to rectify the equipments through the application of troubleshooting tools.
Automation through PLC and DCS,Fieldbus,Modbus and OPC(PLC to DCS) communication.
Follow the Proper & Modified Technical Drawing for installation work.
Review of all P&IDdrawings & documents, Supervision and inspection of field works.
Review and modification of sequence logic,control loop diagram .
Skilled to read Engineering Drawings, Loop Diagrams, P&ID Drawing, Logic Diagram .
Creating & executing of new Design in accordance with the Dynamic Requirement of the Project.
Execution of Creative Benchmark, Planning & scheduling of the Instrumentation work activities in Site to achieve the target completion, most efficient output of Boiler Work.
To ensure that the instruments are installed in accordance with the design specification & requirements.
PRESENT EXPERIENCE :
Company Name : Doosan Power System IndiaPvt.Ltd
Working place :2X 800 MW NTPC Lara,Raigarh
Designation : Assistant Manager.
Duration : From 08-04-2016 to till Date.
PREVIOUS EXPERIENCE :
1.
Company Name : Doosan Power System IndiaPvt.Ltd
Working place : 2X685 MW GMR Power,Raipur.
Designation :Sr.Commissioning Engineer.
Duration : From 04-04-2014 to 30-01-2016.
2.
Company Name :Heavy Engineering Corporation limited
Ranchi for CHP Project ( Payroll of P M Dimensions ) .
Working place : NCL,Krishanshila project ( CHP ).
Designation : Assistant Manager- Electronics
Duration : From 17-07-2013 to 31-03-2014
3.
Company Name :Doosan Heavy Industries & Construction Co. Ltd
Designation : C&I-Commissioning Engineer(Boiler).
Work place :3X660MW STPP, NTPC,Bilaspur..
Duration : From 22-08-2010 to 13-07-2013.
4.
Company Name : Josts Engineering company Ltd
Designation : Engineer Project & Service
Duration : From August 2009 to August 2010.
JOB PROFILE: ( Current,Previous Employer 1 & Previous Employer 3 )
Commissioing of Turbile Auxilary viz..BOP,LOP,SOP,HPU System & respective operation of these system with Turbine Mark VI
Commissioning and Calibration Hydralic Operated Valve s and Hydralic Power system (HP ByPass Valve,LPByPassValve,WR & ZR Valves,MSV, Main Steam & Reheat Control Valve) .
Commissioning and Calibration of gravimetric Coal feeder(Stock),
Commissioning of Boiler Burner System (Oil gun and ignitor, flame Scanner (Forney) )
Commissioning,Repairing & maintenanceof MOV (auma germany & auma india, Rotork).
Commissioning and Repairing of Control Valves(WEIR)with ABB.Siemens,YTC positioner, Dampers & Power cylinder.
Calibration, testing and installation of Bently nevada vibration sensors in TURBINE, ID, FD, MILL,BFP Area.(proximity,velometer,accelrometer)
Calibration and maintenance of EMERSON O2 analyzer, CODEL CO analyzer,Dust analyzer.
Calibration, Commissioning and maintenance of smart transmitter like pressure, level, flow,temperature (Rosemount, foxboro,Yokogawa,Siemens,ABB), Ultrasonic level transmitter.
Temperature Element (Thermocouple & RTD with Thermowell), Digital Flow Meter, HDLS.
Calibration & Commissioning of FTMS Furnace temprature monitoring system(Acoustic pyrometer).
Commissioning of solenoid valves, Pneumatic Type Valve & Gates,Control valve Positioner .
level Switch float type, ultrasonic,magnetic, capacitive type.
Calibration, Installation, and maintenance of Switches like pressure, level, temperature etc.
Instalation and Calibration of Pressure Indicator, Pressure Switch, Pressure Transmitter, Diff. Pressure Transmitter, Flow Transmitter, Temperature Transmitter, Temperature Element (RTD and Thermocouple), Digital Flow Meter.
Instruments erection, preparing cable schedule, cabling from field Instrument to field JB & JB to PLC or DCS loop checking, ferruling, cable termination etc. Local Control Panels erection, Testing and Commissioning for system wise.
Troubleshooting on Soot blower control panel.
JOB PROFILE: ( Previous Employer 2)
Assistant Manager Project ( Electronics )
I have worked on Northern Coalfields limited [NCL],Krishanshila project ( coal handling plant ) . In this package my main scope involves
Preparing Basic Engineering (PLC Input/output,HT & LT Power cable calculation, control cable schedule, transformer sizing calculation, capacitor sizing calculation) & Detail Engineering Drawings (cable & cable tray layout, earthing & lightening layout etc ) in Auto Cad.
Co-ordination for approval of drawings with our Consultant M/s CMPDIL (Central Mine Planning & Design Institute Limited) & customer NCL
Preparing Technical specifications for items (Transformer, power & control cable, HT & LT Motor, PLC, condition monitoring system, LSIS, CONTROL DESK, Bunker & Crusher bin level indicator, safety switches .etc ) used in our project as per contract agreement signed between HECL & NCL .
Making evaluation and comparative statements for offers given by approved vendors
Preparing final technical part of purchase order for bought out items.
Verifying the vendor drawings (Apron feeder, belt feeder, Mobile Tripper,Plough feeder, Rapid Loading system, Metal detector,Inline magnetic separator etc) and submit for approval to CMPDIL.
Going to inspection at Customer works shop to inspect the equipment as per our technical requirement before dispatch.
Inspection at site in front of client [NCL] before erection..
JOB PROFILE: ( Previous Employer 4 )
Installation/ Commissioning/ Projects
Reporting to all India Project & Service Head in Head Office.
Generate Service revenue of 60 LPA by AMCs, Spare Parts Business .
Handle Man Power during the Installation & Commissioning of the systems.
Training to the customer/ Engineers about our Project, Machinery & Systems.
Commissioning & Maintenance of Heat & Combustion,Oil & Gas Systems(Honeywell)
Travelling temp. recorder Data Loggers (FLUKE, Datapaq)
Electrical & Pneumatic Valves, P&ID Diagrams, Electrical Diagrams
Combustion Management System- MAXON (Honeywell).
Flow Measurement/ Survey & Control (GE-Sensing Instruments), Capital Machinery
Gas Leak Detection (ISC OLDHAM), Temperature Controls (Honeywell Automation).
ACADEMIC DETAILS :
Educaion
Board/University
Institution
Year
% Of Marks
B.Tech (E &I)
UPTU,Lucknow
BIT,Muzzafarnagar,UP
2009
62%
H.S.C(+2)
STATE BOARD
BSEB, Patna
1999
52%
S.S.C (10th)
STATE BOARD
BICB, Patna
1997
58 %
PERSONAL DETAILS :
Father s Name : Sri Omprakash singh
Permanent Address : Vill. Ahiroli rai
Post :- Ahiroli Bazar
P.S : Kasya
Kushinagar -274305
Date of Birth : 01.04.1982
Marital Status : married.
Languages known : English,Hindi,Bhojpuri.
Nationality : Indian
Alternate email address : ************@*****.**.**.
DECLARATION :
I hereby declare that the above furnished information is true to the best of my knowledge and belief.
Date :Sincerely,
Place: